Tangential volumetric modulated arc therapy technique for left-sided breast cancer radiotherapy

被引:99
|
作者
Viren, Tuomas [1 ]
Heikkila, Janne [1 ]
Myllyoja, Kimmo [1 ]
Koskela, Kristiina [1 ]
Lahtinen, Tapani [1 ]
Seppala, Jan [1 ]
机构
[1] Kuopio Univ Hosp, Ctr Canc, FI-70029 Kuopio, Finland
来源
RADIATION ONCOLOGY | 2015年 / 10卷
关键词
Radiotherapy; Breast cancer; VMAT; IMRT; Low dose volume; SUPINE POSITION; HEART-DISEASE; RADIATION; WOMEN; PRONE; IMRT; RISK; IRRADIATION; STANDARD;
D O I
10.1186/s13014-015-0392-x
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The aim of the present study was to introduce a new restricted tangential volumetric modulated arc therapy (tVMAT) technique for whole breast irradiation and compare its dosimetric properties to other currently used breast cancer radiotherapy techniques. Method: Ten consecutive women with left-sided breast cancer were enrolled in this retrospective study. Four treatment plans were generated for each patient: 1) standard tangential field-in-field (FinF), 2) tangential intensity modulated radiotherapy (tIMRT), 3) tangential VMAT (tVMAT) with two dual arcs of 50-60 degrees and 4) continuous VMAT (cVMAT) with a dual arc of 240 degrees. The plans were created with Monaco (R) (tIMRT, tVMAT and cVMAT) and Oncentra (R) (FinF) treatment planning systems. Results: With both VMAT techniques significantly higher cardiac avoidance, dose coverage and dose homogenity were achieved when compared with FinF or tIMRT techniques (p < 0.01). VMAT techniques also decreased the high dose areas (above 20 Gy) of ipsilateral lung. There were no significant differences in the mean dose of contralateral breast between the tVMAT, tIMRT and FinF techniques. The dose coverage (V47.5 Gy) was greatest with cVMAT. However, with cVMAT the increase of contralateral breast dose was significant. Conclusions: The present results support the hypothesis that the introduced tVMAT technique is feasible for treatment of left-sided breast cancer. With tVMAT dose to heart and ipsilateral lung can be reduced and the dose homogeneity can be improved without increasing the dose to contralateral breast or lung.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Tangential volumetric modulated arc therapy technique for left-sided breast cancer radiotherapy
    Tuomas Virén
    Janne Heikkilä
    Kimmo Myllyoja
    Kristiina Koskela
    Tapani Lahtinen
    Jan Seppälä
    [J]. Radiation Oncology, 10
  • [2] Non-coplanar volumetric modulated arc therapy for locoregional radiotherapy of left-sided breast cancer including internal mammary nodes
    Xu, Yuan
    Ma, Pan
    Hu, Zhihui
    Tian, Yuan
    Men, Kuo
    Wang, Shulian
    Xu, Yingjie
    Dai, Jianrong
    [J]. RADIOLOGY AND ONCOLOGY, 2021, 55 (04) : 499 - 507
  • [3] Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer
    Lin, Jia-Fu
    Yeh, Dah-Cherng
    Yeh, Hui-Ling
    Chang, Chen-Fa
    Lin, Jin-Ching
    [J]. MEDICAL DOSIMETRY, 2015, 40 (03) : 262 - 267
  • [4] Auto-Planning of Volumetric Modulated Arc Treatment Consisting of Multiple Short Tangential Arcs for Left-Sided Breast Cancer
    Liu, R.
    Qi, X.
    Miller, C.
    Liu, T.
    Bucy, S.
    Ewald, L.
    Kalbaugh, K.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E302 - E302
  • [6] Helical Tomotherapy for left-sided breast: dosimetric comparison to Volumetric-Modulated Arc Therapy
    Ertan, F.
    Tanriseven, R.
    Yazici, O.
    Kocer, A. M.
    Altundag, M. B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S796 - S797
  • [7] Dosimetric Comparison of Whole Breast Radiotherapy Using Field-in-Field and Volumetric Modulated Arc Therapy Techniques in Left-Sided Breast Cancer Patients
    Waheed, Asmara
    Butt, Sumera
    Ishtiaq, Ali
    Mansha, Muhammad Atif
    Mehreen, Sana
    Raza, Mohsin
    Yousaf, Muhammad
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (06)
  • [8] Dosimetric Comparison to Organs at Risk Sparing Using Volumetric-Modulated Arc Therapy Versus Intensity-Modulated Radiotherapy in Postoperative Radiotherapy of Left-Sided Breast Cancer
    Qiao, L.
    Xie, J.
    Cheng, J.
    Liang, N.
    Deng, G.
    Zhang, J.
    Zhang, J.
    Luo, H.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3238 - 3238
  • [9] Comparison of volumetric modulated arc therapy and intensity-modulated radiotherapy for left-sided whole-breast irradiation using automated planning
    L. Redapi
    L. Rossi
    L. Marrazzo
    J. J. Penninkhof
    S. Pallotta
    B. Heijmen
    [J]. Strahlentherapie und Onkologie, 2022, 198 : 236 - 246
  • [10] Comparison of volumetric modulated arc therapy and intensity-modulated radiotherapy for left-sided whole-breast irradiation using automated planning
    Redapi, L.
    Rossi, L.
    Marrazzo, L.
    Penninkhof, J. J.
    Pallotta, S.
    Heijmen, B.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2022, 198 (03) : 236 - 246