The measurement of the presampled MTF of a high spatial resolution neutron imaging system

被引:23
|
作者
Cao, Raymond Lei. [1 ]
Biegalski, Steven R. [1 ]
机构
[1] Univ Texas Austin, Nucl Engn Teaching Lab, Austin, TX 78712 USA
关键词
spatial resolution; presampled MTF; edge method; MCP neutron detector; neutron imaging;
D O I
10.1016/j.nima.2007.08.213
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high spatial resolution neutron imaging device was developed at the Mark II TRIGA reactor at The University of Texas at Austin. As the modulation transfer function (MTF) is recognized as a well-established parameter for evaluation of imaging system resolution, the aliasing associated with digital sampling adds complexity to its measurement. Aliasing is especially problematic when using a high spatial resolution micro-channel plate (MCP) neutron detector that has a pixel grid size similar to that of a CCD array. To compensate for the aliasing an angulated edge method was used to evaluate the neutron imaging facility, overcoming aliasing by obtaining an oversampled edge spread function (ESF). Baseline correction was applied to the ESF to remove the noticeable trends and the LSF was multiplied by Hann window to obtain a smoothed version of presampled MTF. The computing procedure is confirmed by visual inspection of a testing phantom; in addition, it is confirmed by comparison to the MTF measurement of a scintillation screen with a known MTF curve. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:621 / 628
页数:8
相关论文
共 50 条
  • [31] High spatial resolution IoT based air PM measurement system
    Ebru İçöz
    Fasih M. Malik
    Kutay İçöz
    Environmental and Ecological Statistics, 2021, 28 : 779 - 792
  • [32] High spatial resolution IoT based air PM measurement system
    Icoz, Ebru
    Malik, Fasih M.
    Icoz, Kutay
    ENVIRONMENTAL AND ECOLOGICAL STATISTICS, 2021, 28 (04) : 779 - 792
  • [33] Measurement of Water Content in Polymer Electrolyte Membranes using High Resolution Neutron Imaging
    Spernjak, Dusan
    Mukherjee, Partha P.
    Mukundan, Rangachary
    Davey, John
    Hussey, Daniel S.
    Jacobson, David L.
    Borup, Rodney L.
    POLYMER ELECTROLYTE FUEL CELLS 10, PTS 1 AND 2, 2010, 33 (01): : 1451 - +
  • [34] Research on Spatial Noise of High Resolution Thermal Infrared Imaging System
    Ji Hongzhen
    Li Chunlai
    Chen Xiaowen
    Jin Jian
    Yuan Liyin
    Lv Gang
    Wang Jianyu
    MULTISPECTRAL, HYPERSPECTRAL, AND ULTRASPECTRAL REMOTE SENSING TECHNOLOGY, TECHNIQUES AND APPLICATIONS V, 2014, 9263
  • [35] Criterion of spatial resolution of imaging system
    Borovytsky, Volodymyr N.
    Tuzhanskyi, Stanislav Ye.
    Kotyra, Andrzej
    Yerkeldessova, Gulzada
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2019, 2019, 11176
  • [36] Photoplethysmographic imaging of high spatial resolution
    Kamshilin, Alexei A.
    Miridonov, Serguei
    Teplov, Victor
    Saarenheimo, Riku
    Nippolainen, Ervin
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (04): : 996 - 1006
  • [37] Angular resolution of a neutron scatter imaging system
    Zhang Mei
    Zhang Xian-Peng
    Li Kui-Nian
    Sheng Liang
    Yuan Yuan
    Song Chao-Hui
    Li Yang
    ACTA PHYSICA SINICA, 2015, 64 (04)
  • [38] Effect of MTF on Depth Resolution in Imaging Three-dimensional Ladar System
    Jiang, Yanbing
    PROCEEDINGS OF 2012 INTERNATIONAL CONFERENCE ON IMAGE ANALYSIS AND SIGNAL PROCESSING, 2012, : 404 - 407
  • [39] A sensitive high resolution neutron imaging detector
    Cheng, YT
    Mildner, DFR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 454 (2-3): : 452 - 459
  • [40] Unlocking high spatial resolution in neutron imaging through an add-on fibre optics taper
    Morgano, M.
    Trtik, P.
    Meyer, M.
    Lehmann, E. H.
    Hovind, J.
    Strobl, M.
    OPTICS EXPRESS, 2018, 26 (02): : 1809 - 1816