The measurement of the presampled MTF of a high spatial resolution neutron imaging system

被引:23
|
作者
Cao, Raymond Lei. [1 ]
Biegalski, Steven R. [1 ]
机构
[1] Univ Texas Austin, Nucl Engn Teaching Lab, Austin, TX 78712 USA
关键词
spatial resolution; presampled MTF; edge method; MCP neutron detector; neutron imaging;
D O I
10.1016/j.nima.2007.08.213
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high spatial resolution neutron imaging device was developed at the Mark II TRIGA reactor at The University of Texas at Austin. As the modulation transfer function (MTF) is recognized as a well-established parameter for evaluation of imaging system resolution, the aliasing associated with digital sampling adds complexity to its measurement. Aliasing is especially problematic when using a high spatial resolution micro-channel plate (MCP) neutron detector that has a pixel grid size similar to that of a CCD array. To compensate for the aliasing an angulated edge method was used to evaluate the neutron imaging facility, overcoming aliasing by obtaining an oversampled edge spread function (ESF). Baseline correction was applied to the ESF to remove the noticeable trends and the LSF was multiplied by Hann window to obtain a smoothed version of presampled MTF. The computing procedure is confirmed by visual inspection of a testing phantom; in addition, it is confirmed by comparison to the MTF measurement of a scintillation screen with a known MTF curve. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:621 / 628
页数:8
相关论文
共 50 条
  • [1] MTF Measurement of EBCCD Imaging System by Using Super Resolution Technique
    左昉
    高岳
    高稚允
    苏美开
    周立伟
    Journal of Beijing Institute of Technology, 2003, (02) : 125 - 128
  • [2] MTF measurement of EBCCD imaging system by using super resolution technique
    Dept. of Optical Eng., Sch. of Info. Sci. and Technol., Beijing Inst. of Technol., Beijing 100081, China
    Journal of Beijing Institute of Technology (English Edition), 2003, 12 (02): : 125 - 128
  • [3] Spatial resolution limit study of a CCD camera and scintillator based neutron imaging system according to MTF determination and analysis
    Kharfi, F.
    Denden, O.
    Bourenane, A.
    Bitam, T.
    Ali, A.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (01) : 162 - 166
  • [4] High-spatial-resolution measurement of magnetization distribution using polarized neutron imaging
    Sasada, S.
    Hiroi, K.
    Osanai, K.
    Shinohara, T.
    Watanabe, K.
    Uritani, A.
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2021, 60 (12)
  • [5] A high spatial resolution sensor for thermal neutron Imaging
    Shestakova, Irina
    Ovechkina, Elena
    Gaysinskiy, Valeriy
    Antal, John J.
    Bobek, Leo
    Nagarkar, Vivek
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1797 - 1800
  • [6] A High Spatial Resolution Sensor For Thermal Neutron Imaging
    Shestakova, Irina
    Ovechkina, Elena
    Gaysinskiy, Valeriy
    Antal, John J.
    Bobek, Leo
    Nagarkar, Vivek V.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 189 - 192
  • [7] Adaptation of Spatial Resolution for High Resolution Imaging System
    Eckardt, Andreas
    Williges, Christian
    Reulke, Ralf
    OPTICS AND PHOTONICS FOR INFORMATION PROCESSING XI, 2017, 10395
  • [8] An approach for MTF measurement of discrete imaging system
    Zuo, F
    Gao, ZY
    Su, MK
    Liu, GG
    ELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY III, 2002, 4925 : 668 - 673
  • [9] LiF crystals as high spatial resolution neutron imaging detectors
    Matsubayashi, M.
    Faenov, A.
    Pikuz, T.
    Fukuda, Y.
    Kato, Y.
    Yasuda, R.
    Iikura, H.
    Nojima, T.
    Sakai, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 651 (01): : 90 - 94
  • [10] A High Spatial Resolution Neutron Imaging System Using the Micro-Channel Plate Detector
    Cao, L.
    Biegalski, S. R.
    O'Kelly, D. S.
    NEUTRON RADIOGRAPHY, 2008, : 525 - 535