CdZnTe (CZT) is a wide bandgap II-VI semiconductor developed for the spectroscopic detection of X-rays and gamma-rays at room temperature. The Swift Burst Alert Telescope is using an 5240 cm(2) array of 2 mm thick CZT detectors for the detection of 15-150 key X-rays from Gamma-ray Bursts. We report on the systematic tests of thicker ( >= 0.5 cm) CZT detectors with volumes between 2 cm(3) and 4 cm(3) which are potential detector choices for a number of future X-ray telescopes that operate in the 10 keV to a few MeV energy range. The detectors contacted in our laboratory achieve Full Width Half Maximum energy resolutions of 2.7 key (4.5%) at 59 keV, 3 keV (2.5%) at 122 key and 4 key (0.6%) at 662 keV. The 59 keV and 122 keV energy resolutions are among the world-best results for >= 0.5 cm thick CZT detectors. We use the data set to study trends of how the energy resolution depends on the detector thickness and on the pixel pitch. Unfortunately, we do not find clear trends, indicating that even for the extremely good energy resolutions reported here, the achievable energy resolutions are largely determined by the properties of individual crystals. Somewhat surprisingly, we achieve the reported results without applying a correction of the anode signals for the depth of the interaction. Measuring the interaction depths thus does not seem to be a pre-requisite for achieving sub-1% energy resolutions at 662 keV. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:769 / 777
页数:9
相关论文
共 50 条
  • [21] Optics for EUV, X-Ray, and Gamma-Ray Astronomy VI Introduction
    Pareschi, Giovanni
    O'Dell, Steven L.
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY VI, 2013, 8861
  • [22] A THICK ANGER CAMERA FOR GAMMA-RAY ASTRONOMY
    COOK, WR
    FINGER, M
    PRINCE, TA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) : 129 - 133
  • [23] Simulation studies of CZT detectors as gamma-ray calorimeter
    Jung, I.
    Krawczynski, H.
    Komarov, S.
    Sobotka, L.
    ASTROPARTICLE PHYSICS, 2006, 26 (02) : 119 - 128
  • [24] Air shower detectors in gamma-ray astronomy
    Sinnis, G.
    NEW JOURNAL OF PHYSICS, 2009, 11
  • [25] LARGE-AREA MULTI-CRYSTAL NAI(TI) DETECTORS FOR X-RAY AND GAMMA-RAY ASTRONOMY
    FISHMAN, GJ
    AUSTIN, RW
    NUCLEAR INSTRUMENTS & METHODS, 1977, 140 (01): : 193 - 196
  • [26] Crystal Defects and Charge Collection in CZT X-Ray and Gamma Detectors
    Marchini, L.
    Zappettini, A.
    Zha, M.
    Zambelli, N.
    Bolotnikov, A.
    Camarda, G.
    James, R. B.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3674 - 3677
  • [27] CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems
    Eisen, Y
    Shor, A
    Mardor, I
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 1191 - 1198
  • [28] Interconnect and bonding techniques for pixelated X-ray and gamma-ray detectors
    Schneider, A.
    Veale, M. C.
    Duarte, D. D.
    Bell, S. J.
    Wilson, M. D.
    Lipp, J. D.
    Seller, P.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [29] Effects of Chemomechanical Polishing on CdZnTe X-ray and Gamma-Ray Detectors
    Egarievwe, Stephen U.
    Hossain, Anwar
    Okwechime, Ifechukwude O.
    Gul, Rubi
    James, Ralph B.
    JOURNAL OF ELECTRONIC MATERIALS, 2015, 44 (09) : 3194 - 3201
  • [30] X-RAY AND GAMMA-RAY DETECTORS BASED ON MERCURY DIIODIDE CRYSTALS
    ZALETIN, VM
    KOCHEVANOV, VA
    NOZHKINA, IN
    TANSKAYA, NA
    FOMIN, VI
    SOVIET ATOMIC ENERGY, 1982, 52 (03): : 199 - 202