Air Quality in Puerto Rico in the Aftermath of Hurricane Maria: A Case Study on the Use of Lower Cost Air Quality Monitors

被引:48
|
作者
Subramanian, R. [1 ]
Ellis, Aja [1 ,5 ]
Torres-Delgado, Elvis [2 ]
Tanzer, Rebecca [1 ]
Malkings, Carl [1 ]
Rivera, Felipe [3 ]
Morales, Maite [2 ]
Baumgardner, Darrel [4 ]
Presto, Albert [1 ]
Mayol-Bracero, Olga L. [2 ]
机构
[1] Carnegie Mellon Univ, Ctr Atmospher Particle Studies, Pittsburgh, PA 15213 USA
[2] Univ Puerto Rico Rio Piedras, Dept Environm Sci, San Juan, PR 00925 USA
[3] Univ Puerto Rico Rio Piedras, Dept Chem, San Juan, PR 00925 USA
[4] Droplet Measurement Technol, Longmont, CO 80503 USA
[5] Ohio State Univ, Byrd Polar & Climate Res Ctr, Columbus, OH 43210 USA
来源
ACS EARTH AND SPACE CHEMISTRY | 2018年 / 2卷 / 11期
关键词
sulfur dioxide; carbon monoxide; Hurricane Maria; low-cost sensors; air quality; backup generators; AMBIENT SULFUR-DIOXIDE; PARTICULATE MATTER; SENSOR PERFORMANCE; CARBON PARTICLES; BLACK CARBON; DIESEL; CALIBRATION; MORTALITY; POLLUTION; MARKERS;
D O I
10.1021/acsearthspacechem.8b00079
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the aftermath of Hurricane Maria, the electricity grid in Puerto Rico was devastated, with over 90% of the island without electricity; as of December 2017, about 50% of the island lacked electricity and power outages were common elsewhere. Backup generators were widely used, sometimes as the main source of electricity. The hurricane also damaged the island's existing air monitoring network and the University of Puerto Rico's observing facilities. We deployed four lower cost air quality monitors [real-time affordable multi-pollutant (RAMP) monitors] and a black carbon (BC) monitor in the San Juan Metro Area in November 2017. The first month of data collected with the RAMPs showed high sulfur dioxide (SO2) and carbon monoxide (CO) concentrations of varying magnitudes each night. SO2 and CO are strongly correlated (r(2) > 0.9) at two sites similar to 5 km apart (University of Puerto Rico-Rio Piedras and an industrial area, Puerto Nuevo), suggesting a single source type. BC measured at the UPR site is also well-correlated with CO and SO2. While the RAMPs are not certified as a federal equivalent method, the RAMP SO2 data suggest that the United States Environmental Protection Agency (U.S. EPA)'s daily 1 h threshold for SO2 (75 ppb) was exceeded on almost 80% of the first 30 days of deployment (November-December 2017). The widespread reliance on generators for regular electric supply in the aftermath of Hurricane Maria appears to have increased air pollution in San Juan.
引用
收藏
页码:1179 / 1186
页数:15
相关论文
共 50 条
  • [21] How standardizing 'low-cost' air quality monitors will help measure pollution
    Brown, Richard J. C.
    Martin, Nicholas A.
    NATURE REVIEWS PHYSICS, 2023, 5 (03) : 139 - 140
  • [22] Using Low-Cost PM Monitors to Detect Local Changes of Air Quality
    Rogulski, Mariusz
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2018, 27 (04): : 1699 - 1705
  • [23] How standardizing ‘low-cost’ air quality monitors will help measure pollution
    Richard J. C. Brown
    Nicholas A. Martin
    Nature Reviews Physics, 2023, 5 : 139 - 140
  • [24] Domestic energy use and air quality; a case study of the city of Belfast
    Lo, SNG
    Norton, B
    Mannis, A
    APPLIED ENERGY, 2001, 68 (01) : 1 - 18
  • [25] PV-Battery Systems for Critical Loads During Emergencies A Case Study from Puerto Rico After Hurricane Maria
    Keerthisinghe, Chanaka
    Ahumada-Paras, Mareldi
    Pozzo, Lilo D.
    Kirschen, Daniel S.
    Pontes, Hugo
    Tatum, Wesley K.
    Matos, Marvi A.
    IEEE POWER & ENERGY MAGAZINE, 2019, 17 (01): : 82 - 92
  • [26] Ambient air quality at Visakhapatnam - A case study
    Mudri, S.S.
    Rao, D.V.
    Rama Rao, K.G.
    Indian Journal of Environmental Health, 1986, 28 (04) : 284 - 295
  • [27] Fuzzy Description of Air Quality: A Case Study
    Yadav, Jyoti Y.
    Kharat, Vilas
    Deshpande, Ashok
    ROUGH SETS AND KNOWLEDGE TECHNOLOGY, 2011, 6954 : 420 - +
  • [28] Air quality in street canyons: a case study
    Patania, F.
    Gagliano, A.
    Nocera, F.
    Galesi, A.
    AIR POLLUTION XVII, 2009, 123 : 3 - +
  • [29] Optimal Field Calibration of Multiple IoT Low Cost Air Quality Monitors: Setup and Results
    Esposito, E.
    D'Elia, G.
    Ferlito, S.
    Del Giudice, A.
    Fattoruso, G.
    D'Auria, P.
    De Vito, S.
    Di Francia, G.
    COMPUTATIONAL SCIENCE AND ITS APPLICATIONS - ICCSA 2020, PT V, 2020, 12253 : 700 - 708
  • [30] Low-cost PM monitors as an opportunity to increase the spatiotemporal resolution of measurements of air quality
    Rogulski, Mariusz
    INTERNATIONAL SCIENTIFIC CONFERENCE - ENVIRONMENTAL AND CLIMATE TECHNOLOGIES (CONECT 2017), 2017, 128 : 437 - 444