Capabilities of laser ablation inductively coupled plasma time-of-flight mass spectrometry

被引:43
|
作者
Burger, Marcel [1 ]
Schwarz, Gunnar [1 ]
Gundlach-Graham, Alexander [1 ]
Kaser, Debora [1 ]
Hattendorf, Bodo [1 ]
Guenther, Detlef [1 ]
机构
[1] ETH, Lab Inorgan Chem, Vladimir Prelog Weg 1, CH-8093 Zurich, Switzerland
关键词
ICP-MS; HIGH-RESOLUTION; LA-ICPMS; ELEMENTAL FRACTIONATION; GEOLOGICAL SAMPLES; HIGH-SPEED; CYTOMETRY; DESIGN; SIGNAL; TOFMS;
D O I
10.1039/c7ja00236j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we characterize an inductively coupled plasma time-of-flight mass spectrometry (ICP-TOFMS) instrument (icpTOF, TOFWERK AG, Thun, Switzerland) in combination with laser-ablation sample introduction. Three sample introduction approaches for LA-based ICP-TOFMS analysis are described: (1) steady-state LA with a conventional high-dispersion LA cell, (2) single-pulse analysis with large spot sizes (44 mu m diameter) using a low-dispersion LA cell, and (3) pulse-resolved, high-speed, high-resolution (5 mu m spot sizes) elemental imaging with the same low-dispersion LA cell. These sample-introduction schemes span the range of approaches most interesting for users of LA-ICP-TOFMS, from routine bulk quantification, to low-sample-consumption trace-element analysis, to demanding elemental imaging applications. From steady-state signal intensities, element concentrations in NIST SRM 612 and USGS BCR-2G were quantified within the uncertainty range of the preferred values when NIST SRM 610 was used as the external reference material. Relative deviations were less than 10% in most cases. When using a 44 mu m diameter spot and a laser repetition rate of 10 Hz, limits of detection (LODs) were in the single digit ng g(-1) range for the most sensitive isotopes. Isotope-ratio precision was in the sub per mill regime and governed by counting statistics. Similar accuracies were also achieved in low-dispersion LA-ICP-TOFMS experiments, when NIST SRM 612 and USGS BCR-2G element concentrations were quantified using signal intensities from single 44 mu m diameter laser pulses. LODs were in the tens of ng g(-1) range for most sensitive isotopes resulting in absolute LODs in the tens of attograms. Capabilities of the icpTOF for elemental imaging are demonstrated with pulse-resolved multielemental imaging of a multi-phase geological thin section. With the low-dispersion LA cell and a spot diameter of 5 mu m, aerosol plumes were confined to less than 10 ms, which allowed elemental imaging at a laser repetition rate of 100 Hz with minimized pulse-to-pulse mixing and an adjacent-pixel dynamic range of greater than 10(2). Quantitative results for elements of major, minor and trace concentrations were in agreement with bulk composition of individual regions, which had been determined via petrographic microscopy and high-dispersion laser ablation inductively coupled plasma quadrupole mass spectrometry (LA-ICPQMS). LODs were in the single digit mu g g(-1) range for most sensitive isotopes.
引用
收藏
页码:1946 / 1959
页数:14
相关论文
共 50 条
  • [41] Axial inductively coupled plasma time-of-flight mass spectrometry using direct liquid sample introduction
    Westphal, Craig S.
    McLean, John A.
    Acon, Billy W.
    Allen, Lloyd A.
    Montaser, Akbar
    1600, Royal Society of Chemistry (17):
  • [42] Optimization of a laser ablation-inductively coupled plasma “time of flight” mass spectrometry system for short transient signal acquisition
    Davide Bleiner
    Kathrin Hametner
    D. Günther
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 37 - 44
  • [43] Optimization of a laser ablation-inductively coupled plasma "time of flight" mass spectrometry system for short transient signal acquisition
    Bleiner, D
    Hametner, K
    Günther, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (01): : 37 - 44
  • [44] Preliminary investigation of electrothermal vaporization sample introduction for inductively coupled plasma time-of-flight mass spectrometry
    Mahoney, PP
    Ray, SJ
    Li, GQ
    Hieftje, GM
    ANALYTICAL CHEMISTRY, 1999, 71 (07) : 1378 - 1383
  • [45] Analysis of Inorganic Nanoparticles by Single-particle Inductively Coupled Plasma Time-of-Flight Mass Spectrometry
    Hendriks, Lyndsey
    Gundlach-Graham, Alexander
    Guenther, Detlef
    CHIMIA, 2018, 72 (04) : 221 - 226
  • [46] Axial inductively coupled plasma time-of-flight mass spectrometry using direct liquid sample introduction
    Westphal, CS
    McLean, JA
    Acon, BW
    Allen, LA
    Montaser, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (07) : 669 - 675
  • [47] Imaging mass spectrometry in biological tissues by laser ablation inductively coupled plasma mass spectrometry
    Becker, J. S.
    Su, J.
    Zoriya, M. V.
    Dobrowolska, J.
    Matusch, A.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2007, 13 (01) : 1 - 6
  • [48] Capabilities of femtosecond laser ablation inductively coupled plasma mass spectrometry for depth profiling of thin metal coatings
    Pisonero, J.
    Koch, J.
    Waelle, M.
    Hartung, W.
    Spencer, N. D.
    Guenther, D.
    ANALYTICAL CHEMISTRY, 2007, 79 (06) : 2325 - 2333
  • [49] Soft ablation technique for laser ablation-inductively coupled plasma mass spectrometry
    Tokyo Inst of Technology, Tokyo, Japan
    J Anal At Spectrom, 11 (1337-1342):
  • [50] Laser ablation ion-storage time-of-flight mass spectrometry
    R.E. Russo
    G.L. Klunder
    P. Grant
    B.D. Andresen
    Applied Physics A, 1999, 69 : S895 - S897