Feasibility study on applications of an Earth-air Heat Exchanger (EAHE) for preheating fresh air in severe cold regions

被引:49
|
作者
Li, Hui [1 ,2 ]
Ni, Long [1 ,2 ]
Liu, Guang [3 ]
Zhao, Zisang [4 ]
Yao, Yang [1 ,2 ]
机构
[1] Harbin Inst Technol, Sch Architecture, Harbin 150090, Heilongjiang, Peoples R China
[2] Heilongjiang Prov Key Lab Bldg Energy Efficiency, Harbin 150090, Heilongjiang, Peoples R China
[3] Heilongjiang 904 Geol Survey Inst Hydrogeol Engn, Harbin 150028, Heilongjiang, Peoples R China
[4] Heilongjiang Chenneng Investment & Consultant Co, Harbin 150086, Heilongjiang, Peoples R China
基金
国家重点研发计划;
关键词
Earth-air Heat Exchanger (EAHE); Heating capacity; Severe cold region; Heat recovery; CONDITIONED RESIDENTIAL BUILDINGS; COOLING SYSTEM; PERFORMANCE ANALYSIS; GEOTHERMAL-ENERGY; VENTILATION; POLLUTION; CHINA; POTENTIALS; CAPACITY; WINTER;
D O I
10.1016/j.renene.2018.09.012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Due to high power consumption and air pollution situation in China, insufficient indoor fresh air during heating season can be a noteworthy problem. Unlike previous researches, which mainly focused on cooling capacity of Earth-air Heat Exchanger (EAHE), feasibility of EAHE combined with Heat Recovery Unit (HRU) as an independent heat source to heat cold air in severe cold regions was firstly verified. U-shaped buried pipes were proposed to enhance heat transfer as well as save land-use. Thorough measurements of air and soil parameters and power consumption were conducted under several operation modes, performance indexes like heating capacity, heat transfer efficiency and COP were analyzed. Results showed average temperature rise of 14.0 degrees C provided by EAHE and further 12.1 degrees C promotion brought by HRU helped outdoor air reach to an acceptable level without auxiliary heating equipment. Heating capacity of EAHE increased with decreasing inlet temperature, when inlet temperature changed from -0.4 to 24.4 degrees C, heating capacity increased from 709 W (19.7 W/m) to 7718 W (214.4 W/m). Performance of HRU rarely reacted to climatic conditions because of the stable outlet temperature of EAHE. Maximum comprehensive COP was 16.3, which indicated the high efficiency of system. Results showed EAHE can be expanded to severe cold regions and achieve good efficiency. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1268 / 1284
页数:17
相关论文
共 50 条
  • [31] Parametric Study and Energy Performance of an Earth-Air Heat Exchanger for a Poultry House in Morocco
    Laknizi, Azzeddine
    Mahdaoui, Mustapha
    Anoune, Kamal
    Bakhouya, Mohamed
    Ben Abdellah, Abdelatif
    Oussous, Hamza
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2018, 8 (04): : 2047 - 2056
  • [32] A review on the experimental and analytical analysis of earth to air heat exchanger (EAHE) systems in Turkey
    Ozgener, Leyla
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (09): : 4483 - 4490
  • [33] Influence of coating soil types on the energy of earth-air heat exchanger
    Cuny, Mathias
    Lin, Jian
    Siroux, Monica
    Magnenet, Vincent
    Fond, Christophe
    ENERGY AND BUILDINGS, 2018, 158 : 1000 - 1012
  • [34] EARTH-AIR AND EARTH-WATER HEAT EXCHANGER DESIGN FOR VENTILATION SYSTEMS IN BUILDINGS
    De Paepe, Michel
    T'Joen, Christophe
    Janssens, Arnold
    Steeman, Marijke
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 4: HEAT TRANSFER MEASUREMENT TECHNIQUES, HEAT TRANSFER EQUIPMENT, THERMOELECTRICS, 2010, : 453 - 462
  • [35] Analytical investigation on the optimal tube length of Earth-to-Air Heat Exchanger (EAHE)
    Alikhani, Ali
    Maerefat, Mehdi
    Sobhani, Seyed Mohammad Jafar
    GEOTHERMICS, 2025, 127
  • [36] Feasibility Study on the Application of Earth-Air Heat Exchangers in Archaeological Site Exhibition Facilities
    Fan, Liwen
    Zhang, Ruohan
    Xie, Huarong
    Xia, Changchang
    Li, Yonghui
    Hokoi, Shuichi
    MULTIPHYSICS AND MULTISCALE BUILDING PHYSICS, IBPC 2024, VOL 3, 2025, 554 : 179 - 184
  • [37] Influence of different types of pipes on the heat exchange performance of an earth-air heat exchanger
    Xiao, Jinxin
    Li, Jianming
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 55
  • [38] Experimental study on the characteristics of radiation floor cooling system based on an earth-air heat exchanger
    Yang, Jiaming
    Song, Wei
    Zhang, Houan
    Wang, Jing
    Dong, Jiankai
    ENERGY AND BUILDINGS, 2023, 296
  • [39] A review on modelling, experimental analysis and parametric effects of earth-air heat exchanger
    Ahmad, Saif Nawaz
    Prakash, Om
    MODELING EARTH SYSTEMS AND ENVIRONMENT, 2022, 8 (02) : 1535 - 1551
  • [40] Evaluation of Earth-air Heat Exchanger for Cooling and Heating a Poultry House: Case Study in Morocco
    Laknizi, Azzeddine
    ElMaakoul, Anas
    Ben Abdellah, Abdellatif
    Bouya, Mouhsine
    Dhimdi, Said
    Said, Saadeddine
    PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15), 2015, : 435 - 439