Feasibility study on applications of an Earth-air Heat Exchanger (EAHE) for preheating fresh air in severe cold regions

被引:49
|
作者
Li, Hui [1 ,2 ]
Ni, Long [1 ,2 ]
Liu, Guang [3 ]
Zhao, Zisang [4 ]
Yao, Yang [1 ,2 ]
机构
[1] Harbin Inst Technol, Sch Architecture, Harbin 150090, Heilongjiang, Peoples R China
[2] Heilongjiang Prov Key Lab Bldg Energy Efficiency, Harbin 150090, Heilongjiang, Peoples R China
[3] Heilongjiang 904 Geol Survey Inst Hydrogeol Engn, Harbin 150028, Heilongjiang, Peoples R China
[4] Heilongjiang Chenneng Investment & Consultant Co, Harbin 150086, Heilongjiang, Peoples R China
基金
国家重点研发计划;
关键词
Earth-air Heat Exchanger (EAHE); Heating capacity; Severe cold region; Heat recovery; CONDITIONED RESIDENTIAL BUILDINGS; COOLING SYSTEM; PERFORMANCE ANALYSIS; GEOTHERMAL-ENERGY; VENTILATION; POLLUTION; CHINA; POTENTIALS; CAPACITY; WINTER;
D O I
10.1016/j.renene.2018.09.012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Due to high power consumption and air pollution situation in China, insufficient indoor fresh air during heating season can be a noteworthy problem. Unlike previous researches, which mainly focused on cooling capacity of Earth-air Heat Exchanger (EAHE), feasibility of EAHE combined with Heat Recovery Unit (HRU) as an independent heat source to heat cold air in severe cold regions was firstly verified. U-shaped buried pipes were proposed to enhance heat transfer as well as save land-use. Thorough measurements of air and soil parameters and power consumption were conducted under several operation modes, performance indexes like heating capacity, heat transfer efficiency and COP were analyzed. Results showed average temperature rise of 14.0 degrees C provided by EAHE and further 12.1 degrees C promotion brought by HRU helped outdoor air reach to an acceptable level without auxiliary heating equipment. Heating capacity of EAHE increased with decreasing inlet temperature, when inlet temperature changed from -0.4 to 24.4 degrees C, heating capacity increased from 709 W (19.7 W/m) to 7718 W (214.4 W/m). Performance of HRU rarely reacted to climatic conditions because of the stable outlet temperature of EAHE. Maximum comprehensive COP was 16.3, which indicated the high efficiency of system. Results showed EAHE can be expanded to severe cold regions and achieve good efficiency. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1268 / 1284
页数:17
相关论文
共 50 条
  • [1] Feasibility analysis of Earth-Air Heat Exchanger (EAHE) in a sports and culture center in Tianjin, China
    Cao, Shuanghua
    Li, Fan
    Li, Xin
    Yang, Bing
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 26
  • [2] An experimental study on the use of Earth-Air Heat Exchangers (EAHE)
    Vaz, Joaquim
    Sattler, Miguel A.
    Brum, Ruth da S.
    dos Santos, Elizaldo D.
    Isoldi, Liercio A.
    ENERGY AND BUILDINGS, 2014, 72 : 122 - 131
  • [3] Experimental and analytical studies of earth-air heat exchanger (EAHE) systems in India: A review
    Bisoniya, Trilok Singh
    Kumar, Anil
    Baredar, Prashant
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 19 : 238 - 246
  • [4] Advances in standalone and hybrid earth-air heat exchanger (EAHE) systems for buildings: A review
    Soares, N.
    Rosa, N.
    Monteiro, H.
    Costa, J. J.
    ENERGY AND BUILDINGS, 2021, 253
  • [5] Simulation of dynamic interactions of the earth-air heat exchanger with soil and atmosphere for preheating of ventilation air
    Gan, Guohui
    APPLIED ENERGY, 2015, 158 : 118 - 132
  • [6] Annual performance experiments of an earth-air heat exchanger fresh air-handling unit in severe cold regions: Operation, economic and greenhouse gas emission analyses
    Li, Hui
    Ni, Long
    Yao, Yang
    Sun, Cheng
    RENEWABLE ENERGY, 2020, 146 : 25 - 37
  • [7] Working parameters affecting earth-air heat exchanger (EAHE) system performance for passive cooling: A review
    Darius, D.
    Misaran, M. S.
    Rahman, Md. M.
    Ismail, M. A.
    Amaludin, A.
    INTERNATIONAL CONFERENCE ON MATERIALS TECHNOLOGY AND ENERGY (ICMTE), 2017, 217
  • [8] Design of earth-air heat exchanger system
    Bisoniya, Trilok Singh
    GEOTHERMAL ENERGY, 2015, 3
  • [9] Thermal potential improvement of an earth-air heat exchanger (EAHE) by employing backfilling for deep underground emergency ventilation
    Gao, Xiangkui
    Xiao, Yimin
    Gao, Penghui
    ENERGY, 2022, 250
  • [10] SOIL HEAT-EXCHANGER FOR PREHEATING OF FRESH AIR
    PANZHAUSER, E