Deducing the Optimal Control Method for Electrochromic Triple Glazing through an Integrated Evaluation of Building Energy and Daylight Performance

被引:17
|
作者
Oh, Myunghwan [1 ]
Park, Jaesung [2 ]
Roh, Seungjun [3 ]
Lee, Chulsung [2 ]
机构
[1] Korea Conform Lab, Ctr Bldg Envelope Technol, 595-10 Pyengsin 1 Ro, Seosan 31900, Chungcheongnam, South Korea
[2] Korea Conform Lab, Ctr Bldg Envelope Technol, 73 Yangcheon 3 Gil, Cheongju 28115, Chungcheongbuk, South Korea
[3] Hanyang Univ, Sustainable Bldg Res Ctr, 55 Hanyangdaehak Ro, Ansan 15588, South Korea
关键词
electrochromic glazing; optimum control; optical properties; heating and cooling loads; lighting energy; office building; EnergyPlus; VISUAL COMFORT; WINDOW GLAZINGS;
D O I
10.3390/en11092205
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Electrochromic glass is anticipated as the next generation of solar control glass for construction because it can control the transmittance of the glass itself. This study analyzed building energy and light environment performance by applying electrochromic glass in triple glazing in order to verify both the solar control characteristics of electrochromic glass and its high insulation performance. This paper evaluates the performance of the electrochromic glass developed by our research team in Korea in five control conditions of varying temperatures and solar radiation levels. By analyzing the cooling and heating load, lighting energy, Daylight Glare Index (DGI), and interior illuminance when applying the selected conditions to office buildings, this paper discerns the optimal control conditions for electrochromic glass. To do so, the optical characteristic data of the electrochromic glass was analyzed via an experiment, and the creation of triple glazing for construction was conducted. The performance of electrochromic glass was evaluated by analyzing hourly and yearly data for cooling, heating load, and lighting energy during a typical day in summer and winter. From this analysis, the control condition with an outstanding performance from an energy perspective was identified. The performance of the light environment was assessed, and the EDPI overall evaluation index was used to find the electrochromic glass' optimum control conditions for integrating energy and light environment.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] An integrated simulation method for building energy performance assessment in urban environments
    Yang, Xiaoshan
    Zhao, Lihua
    Bruse, Michael
    Meng, Qinglin
    [J]. ENERGY AND BUILDINGS, 2012, 54 : 243 - 251
  • [22] Integrated building envelope performance evaluation method towards nearly zero energy buildings based on operation data
    Li, Hao
    Li, Yaohong
    Wang, Zhichao
    Shao, Shuangquan
    Deng, Gaofeng
    Xue, Huiyu
    Xu, Zhaowei
    Yang, Yingxia
    [J]. ENERGY AND BUILDINGS, 2022, 268
  • [23] Performance evaluation of an integrated solar water heater as an option for building energy conservation
    Dharuman, C
    Arakeri, JH
    Srinivasan, K
    [J]. ENERGY AND BUILDINGS, 2006, 38 (03) : 214 - 219
  • [24] Integrated Design and a Holistic Building Energy Performance Simulation Method for Staged Practices
    Tian, Zhen
    Lei, Yaping
    [J]. 2018 INTERNATIONAL CONFERENCE ON CIVIL, ARCHITECTURE AND DISASTER PREVENTION, 2019, 218
  • [25] An integrated building energy performance evaluation method: From parametric modeling to GA-NN based energy consumption prediction modeling
    Li, Xiang
    Liu, Sha
    Zhao, Lu
    Meng, Xianhai
    Fang, Yifan
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 45
  • [26] Experiment and simulation to determine the optimum orientation of building-integrated photovoltaic on tropical building façades considering annual daylight performance and energy yield
    Mangkuto, Rizki A.
    Tresna, Dhian Nur Aziz T.
    Hermawan, Ikhwan M.
    Pradipta, Justin
    Jamala, Nurul
    Paramita, Beta
    Atthaillah
    [J]. Energy and Built Environment, 2024, 5 (03): : 414 - 425
  • [27] Numerical evaluation of an optically switchable photovoltaic glazing system for passive daylighting control and energy-efficient building design
    Liu, Xiao
    Wu, Yupeng
    [J]. BUILDING AND ENVIRONMENT, 2022, 219
  • [28] Narrowing uncertainties in forecasting urban building energy demand through an optimal archetyping method
    Gholami, M.
    Torreggiani, D.
    Tassinari, P.
    Barbaresi, A.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2021, 148
  • [29] Performance evaluation of an active and energy regenerative suspension using optimal control
    Yin, Jun
    Chen, Xinbo
    Li, Jianqin
    Qian, Shaoming
    [J]. 2015 34TH CHINESE CONTROL CONFERENCE (CCC), 2015, : 8057 - 8060
  • [30] Evaluation of energy-efficient retrofits in glazing areas of building envelope and the impact of PCM application on energy performance: A case study in İstanbul and Diyarbakir
    Cengiz, Hasan Tunay
    Gedik, Guelay Zorer
    Korkmaz, Ezgi
    [J]. JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2024, 39 (04): : 2395 - 2408