Detection of Onset, Systolic Peak and Dicrotic Notch in Arterial Blood Pressure Pulses

被引:17
|
作者
Singh, Omkar [1 ]
Sunkaria, Ramesh Kumar [1 ]
机构
[1] Dr BR Ambedkar Natl Inst Technol Jalandhar, Dept Elect & Commun Engn, Jalandhar, India
来源
MEASUREMENT & CONTROL | 2017年 / 50卷 / 7-8期
关键词
ALGORITHM;
D O I
10.1177/0020294017729958
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, we proposed an effective method for detecting fiducial points in arterial blood pressure pulses. An arterial blood pressure pulse normally consists of onset, systolic peak and dicrotic notch. Detection of fiducial points in blood pressure pulses is a critical task and has many potential applications. The proposed method employs empirical wavelet transform for locating the systolic peak and onset of blood pressure pulse. The proposed method first estimates the fundamental frequency of blood pressure pulse using empirical wavelet transform and utilizes the combination of the blood pressure pulse and the estimated frequency for locating onset and systolic peak. For dicrotic notch detection, it utilizes the first-order difference of blood pressure pulse. The algorithm was validated on various open-source databases and was tested on a data set containing 12,230 beats. Two benchmark parameters such as sensitivity and positive predictivity were used for the performance evaluation. The comparison results for accuracy of the detection of systolic peak, onset and dicrotic notch are reported. The proposed method attained a sensitivity and positive predictivity of 99.95% and 99.97%, respectively, for systolic peaks. For onsets, it attained a sensitivity and predictivity of 99.88% and 99.92%, respectively. For dicrotic notches, a sensitivity and positive predictivity of 98.98% and 98.81% were achieved, respectively.
引用
收藏
页码:170 / 176
页数:7
相关论文
共 50 条
  • [1] Detection of Dicrotic Notch in Arterial Pressure Signals
    S.A.A.P. Hoeksel
    J.R.C. Jansen
    J.A. Blom
    J.J. Schreuder
    [J]. Journal of Clinical Monitoring, 1997, 13 : 309 - 316
  • [2] Detection of dicrotic notch in arterial pressure signals
    Hoeksel, SAAP
    Jansen, JRC
    Blom, JA
    Schreuder, JJ
    [J]. JOURNAL OF CLINICAL MONITORING, 1997, 13 (05) : 309 - 316
  • [3] Atypical dicrotic notch in arterial blood pressure waveform morphology
    Hsieh, Shao-Wei
    Hung, Kuo-Chuan
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2016, 35 : 238 - 239
  • [4] Accurate end systole detection in dicrotic notch-less arterial pressure waveforms
    Joel Balmer
    Rachel Smith
    Christopher G. Pretty
    Thomas Desaive
    Geoff M. Shaw
    J. Geoffrey Chase
    [J]. Journal of Clinical Monitoring and Computing, 2021, 35 : 79 - 88
  • [5] Accurate end systole detection in dicrotic notch-less arterial pressure waveforms
    Balmer, Joel
    Smith, Rachel
    Pretty, Christopher G.
    Desaive, Thomas
    Shaw, Geoff M.
    Chase, J. Geoffrey
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (01) : 79 - 88
  • [6] Onset Detection in Arterial Blood Pressure pulses using Empirical Wavelet Transform
    Singh, Omkar
    Sunkaria, Ramesh Kumar
    [J]. 2015 2ND INTERNATIONAL CONFERENCE ON COMPUTING FOR SUSTAINABLE GLOBAL DEVELOPMENT (INDIACOM), 2015, : 1612 - 1615
  • [7] Controversy over the dicrotic notch and wave in the blood pressure record
    Geddes, LA
    Roeder, R
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2002, 21 (05): : 167 - 169
  • [8] Dicrotic Notch Identification: a Generalizable Hybrid Approach under Arterial Blood Pressure (ABP) Curve Deformations
    Saffarpour, Mahya
    Basu, Debraj
    Radaei, Fatemeh
    Vali, Kourosh
    Adams, Jason Y.
    Chuah, Chen-Nee
    Ghiasi, Soheil
    [J]. 2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 4424 - 4427
  • [9] A Novel Parameter from PPG Dicrotic Notch for Estimation of Systolic Blood Pressure Using Pulse Transit Time
    Gu, W. B.
    Poon, C. C. Y.
    Zhang, Y. T.
    [J]. 2008 5TH INTERNATIONAL SUMMER SCHOOL AND SYMPOSIUM ON MEDICAL DEVICES AND BIOSENSORS, 2008, : 292 - 294
  • [10] An algorithm to detect dicrotic notch in arterial blood pressure and photoplethysmography waveforms using the iterative envelope mean method
    Pal, Ravi
    Rudas, Akos
    Kim, Sungsoo
    Chiang, Jeffrey N.
    Barney, Anna
    Cannesson, Maxime
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 254