An algorithm to detect dicrotic notch in arterial blood pressure and photoplethysmography waveforms using the iterative envelope mean method

被引:0
|
作者
Pal, Ravi [1 ]
Rudas, Akos [2 ]
Kim, Sungsoo [1 ]
Chiang, Jeffrey N. [2 ]
Barney, Anna [3 ]
Cannesson, Maxime [1 ]
机构
[1] Univ Calif Los Angeles, Dept Anesthesiol & Perioperat Med, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Computat Med, Los Angeles, CA USA
[3] Univ Southampton, Inst Sound & Vibrat Res ISVR, Southampton SO17 1BJ, England
基金
美国国家卫生研究院;
关键词
Arterial blood pressure (ABP) waveforms; Photoplethysmography (PPG) waveforms; Dicrotic notch (DN); Systolic phase duration (SPD); Iterative envelope mean (IEM) method; PULSE-WAVE; SOUNDS; ENHANCEMENT; SIGNAL; LUNG; AGE;
D O I
10.1016/j.cmpb.2024.108283
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Detection of the dicrotic notch (DN) within a cardiac cycle is essential for assessment of cardiac output, calculation of pulse wave velocity, estimation of left ventricular ejection time, and supporting feature-based machine learning models for noninvasive blood pressure estimation, and hypotension, or hypertension prediction. In this study, we present a new algorithm based on the iterative envelope mean (IEM) method to detect automatically the DN in arterial blood pressure (ABP) and photoplethysmography (PPG) waveforms. Methods: The algorithm was evaluated on both ABP and PPG waveforms from a large perioperative dataset (MLORD dataset) comprising 17,327 patients. The analysis involved a total of 1,171,288 cardiac cycles for ABP waveforms and 3,424,975 cardiac cycles for PPG waveforms. To evaluate the algorithm's performance, the systolic phase duration (SPD) was employed, which represents the duration from the onset of the systolic phase to the DN in the cardiac cycle. Correlation plots and regression analysis were used to compare the algorithm against marked DN detection, while box plots and Bland-Altman plots were used to compare its performance with both marked DN detection and an established DN detection technique (second derivative). The marking of the DN temporal location was carried out by an experienced researcher using the help of the 'find_peaks' function from the scipy Python package, serving as a reference for the evaluation. The marking was visually validated by both an engineer and an anesthesiologist. The robustness of the algorithm was evaluated as the DN was made less visually distinct across signal-to-noise ratios (SNRs) ranging from -30 dB to -5 dB in both ABP and PPG waveforms. Results: The correlation between SPD estimated by the algorithm and that marked by the researcher is strong for both ABP (R-2(87,343) =0.99, p<.001) and PPG (R-2(86,764) =0.98, p<.001) waveforms. The algorithm had a lower mean error of DN detection (s): 0.0047 (0.0029) for ABP waveforms and 0.0046 (0.0029) for PPG waveforms, compared to 0.0693 (0.0770) for ABP and 0.0968 (0.0909) for PPG waveforms for the established 2nd derivative method. The algorithm has high rate of detectability of DN detection for SNR of >= -9 dB for ABP waveforms and >= -12 dB for PPG waveforms indicating robust performance in detecting the DN when it is less visibly distinct. Conclusion: Our proposed IEM- based algorithm can detect DN in both ABP and PPG waveforms with low computational cost, even in cases where it is not distinctly defined within a cardiac cycle of the waveform ('DN-less signals'). The algorithm can potentially serve as a valuable, fast, and reliable tool for extracting features from ABP and PPG waveforms. It can be especially beneficial in medical applications where DN-based features, such as SPD, diastolic phase duration, and DN amplitude, play a significant role.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Real-time estimation of mean arterial blood pressure based on photoplethysmography dicrotic notch and perfusion index. A pilot study
    Joachim, Jona
    Coutrot, Maxime
    Millasseau, Sandrine
    Mateo, Joaquim
    Mebazaa, Alexandre
    Gayat, Etienne
    Vallee, Fabrice
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (02) : 395 - 404
  • [2] Real-time estimation of mean arterial blood pressure based on photoplethysmography dicrotic notch and perfusion index. A pilot study
    Jona Joachim
    Maxime Coutrot
    Sandrine Millasseau
    Joaquim Matéo
    Alexandre Mebazaa
    Etienne Gayat
    Fabrice Vallée
    [J]. Journal of Clinical Monitoring and Computing, 2021, 35 : 395 - 404
  • [3] Atypical dicrotic notch in arterial blood pressure waveform morphology
    Hsieh, Shao-Wei
    Hung, Kuo-Chuan
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2016, 35 : 238 - 239
  • [4] Accurate end systole detection in dicrotic notch-less arterial pressure waveforms
    Joel Balmer
    Rachel Smith
    Christopher G. Pretty
    Thomas Desaive
    Geoff M. Shaw
    J. Geoffrey Chase
    [J]. Journal of Clinical Monitoring and Computing, 2021, 35 : 79 - 88
  • [5] Accurate end systole detection in dicrotic notch-less arterial pressure waveforms
    Balmer, Joel
    Smith, Rachel
    Pretty, Christopher G.
    Desaive, Thomas
    Shaw, Geoff M.
    Chase, J. Geoffrey
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (01) : 79 - 88
  • [6] Detection of Onset, Systolic Peak and Dicrotic Notch in Arterial Blood Pressure Pulses
    Singh, Omkar
    Sunkaria, Ramesh Kumar
    [J]. MEASUREMENT & CONTROL, 2017, 50 (7-8): : 170 - 176
  • [7] A Fiber Bragg Grating Sensor-based Wearable System to Detect the Pre-dicrotic and Dicrotic Notch in the Arterial Pulse Pressure Waveform
    Jha, Chandan Kumar
    Sinha, Oindrila
    Chakraborty, Arup Lal
    [J]. 2019 IEEE 16TH INDIA COUNCIL INTERNATIONAL CONFERENCE (IEEE INDICON 2019), 2019,
  • [8] Arterial blood pressure feature estimation using photoplethysmography
    Zadi, Armin Soltan
    Alex, Raichel
    Zhang, Rong
    Watenpaugh, Donald E.
    Behbehani, Khosrow
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 102 : 104 - 111
  • [9] Dicrotic Notch Identification: a Generalizable Hybrid Approach under Arterial Blood Pressure (ABP) Curve Deformations
    Saffarpour, Mahya
    Basu, Debraj
    Radaei, Fatemeh
    Vali, Kourosh
    Adams, Jason Y.
    Chuah, Chen-Nee
    Ghiasi, Soheil
    [J]. 2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 4424 - 4427
  • [10] Reconstruction of arterial blood pressure waveforms based on squeeze-and-excitation network models using electrocardiography and photoplethysmography signals
    Zhang, Gengjia
    Choi, Daegil
    Jung, Jaehyo
    [J]. KNOWLEDGE-BASED SYSTEMS, 2024, 295