The use of intraoperative three-dimensional imaging (ISO-C-3D) in fixation of intraarticular fractures

被引:109
|
作者
Atesok, K.
Finkelstein, J.
Khoury, A.
Peyser, A.
Weil, Y.
Liebergall, M.
Mosheiff, R.
机构
[1] Hadassah Univ Hosp, Dept Orthopaed, IL-91120 Jerusalem, Israel
[2] Sunnybrook Hlth Sci Ctr, Dept Orthopaed, Toronto, ON M4N 3M5, Canada
关键词
intraarticular fractures; reduction and implant position; intraoperative CT;
D O I
10.1016/j.injury.2007.06.014
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The purpose of this study was to analyse the applicability and advantages of the intraoperative use of a mobile isocentric C-arm with three-dimensional imaging (Siremobil ISO-C-3D) in fixation of intraarticular fractures. Methods: After the fixation was judged to be satisfactory relying on the images provided by routine fluoroscopy, intraoperative CT visualisation with ISO-C-3D was performed to evaluate the fracture reduction and implant position. Intraoperative revision was performed based on the additional information ISO-C-D provided beyond routine fluoroscopy. ISO-C-3D was used on a series of 72 closed-intraarticular fractures in 70 patients. Fracture distribution was: calcaneus (25), tibial plateau (17), tibia[ plafond (12), acetabulum (11), distat radius (3), ankle Weber-C (3) and femoral head (1). The primary outcome measure was revision rate after final ISO-C-3D data acquisition and prior to wound closure. Secondary objectives were to measure the additional time required for ISO-C-3D use and to determine the rate of further re-do surgeries. Results: Eight out of 72 (11%) fracture fixations were judged by the surgeon to require intraoperative revision following ISO-C-3D imaging. Prior to leaving the operating room, the surgeon was satisfied with fracture alignment in all the procedures. The mean additional operative time using ISO-C-3D was 7.5 min (8.2% of the mean total operative time). No patient required re-do surgery. Conclusion: : Intraoperative three-dimensional visuatisation of intraarticutar fractures enables the surgeon to identify inadvertent malreductions or implant malpositions which may be overlooked by routine C-arm fluoroscopy and hence may eliminate the need for re-do procedures. ISO-C-3D adds Little operative time and may preclude the need for pre-operative and post-operative CT-scans in selected cases. (c) 2007 Elsevier Ltd. Alt rights reserved.
引用
收藏
页码:1163 / 1169
页数:7
相关论文
共 50 条
  • [31] Intraoperative three-dimensional transesophageal echocardiographic imaging of aortic atherosclerosis
    Lazottt, L. W.
    Ciceri, D. P.
    Culp, W. C., Jr.
    ATHEROSCLEROSIS SUPPLEMENTS, 2007, 8 (01) : 138 - 138
  • [32] The Use of Three-Dimensional Printing for Complex Scaphoid Fractures
    Jew, Nicholas
    Lipman, Joseph D.
    Carlson, Michelle G.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (02): : 165.e1 - 165.e6
  • [33] POSTPLANNING OF A THREE-DIMENSIONAL DOSE DISTRIBUTION FOR INTRAOPERATIVE ELECTRON RADIATION THERAPY (IOERT) USING INTRAOPERATIVE C-ARM BASED 3D-IMAGING : A PHANTOM STUDY
    Roeder, F.
    Schramm, O.
    Schwahofer, A.
    Timke, C.
    Habl, G.
    Tanner, M.
    Huber, P.
    Debus, J.
    Krempien, R.
    Hensley, F.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S246 - S247
  • [34] Intraoperative imaging of the shoulder: A comparison of two- and three-dimensional imaging techniques
    Suero, Eduardo M.
    Hawi, Nael
    Citak, Musa
    Decker, Sebastian
    Brandes, Julia
    Meller, Rupert
    Krettek, Christian
    Stuebig, Timo
    TECHNOLOGY AND HEALTH CARE, 2015, 23 (02) : 171 - 177
  • [35] Three-dimensional (3D) Reconstruction of Range Gated Imaging
    Chua, Sing Yee
    Chew, Kuew Wai
    Guo, Ningqun
    Wang, Xin
    2018 IEEE 7TH INTERNATIONAL CONFERENCE ON PHOTONICS (ICP), 2018,
  • [36] Three-dimensional (3D) ultrasound imaging of carotid web
    Binyang Gao
    Yan Luo
    Chenyun Zhou
    Mei Zhang
    Xiaorong Wen
    Acta Neurologica Belgica, 2023, 123 : 1159 - 1160
  • [37] Three-dimensional (3D) ultrasound imaging of carotid web
    Gao, Binyang
    Luo, Yan
    Zhou, Chenyun
    Zhang, Mei
    Wen, Xiaorong
    ACTA NEUROLOGICA BELGICA, 2023, 123 (03) : 1159 - 1160
  • [38] THREE-DIMENSIONAL CT RECONSTRUCTION IN THE IMAGING OF ACETABULAR AND PELVIC FRACTURES
    Venter, A.
    Cioara, F.
    Straciuc, O.
    Pirte, A.
    OSTEOPOROSIS INTERNATIONAL, 2017, 28 : S548 - S548
  • [39] Intraoperative 3-dimensional imaging of scaphoid fracture reduction and fixation
    Luria, S.
    Safran, O.
    Zinger, G.
    Mosheiff, R.
    Liebergall, M.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (03) : 353 - 357
  • [40] Three-dimensional finite element analysis: Anatomical splint fixation for Colles fractures
    Huang, Fei
    Tan, Rui
    Wang, Meng-Wei
    Hu, Liu-Chao
    Wang, Zhi
    Sun, Shi-Dong
    Huang, Jie-Wen
    Luo, Yi-Wen
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2024, 27 (03)