Power Quality Factor Improvement using Shunt Active Power Line Conditioner

被引:0
|
作者
Nagarjuna, Maravathu [1 ]
Panda, P. C. [1 ]
Sandeep, Azmera [1 ]
机构
[1] Natl Inst Technol, Dept Elect Engn, Rourkela 769008, India
关键词
Shunt active power line conditioner; p-q theory; Power quality factor; Hysteresis band current controller; Nonlinear load;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper describes an improvement method of power quality using shunt active power line conditioner ( APLC) for a three phase supply system feeding three phase unbalanced non-linear load. A control algorithm is presented for an APLC to compensate harmonics and unbalance factor. Sensing load currents, dc bus voltages compute reference currents of APLC. APLC driving signals are produced with the reference signals via a hysteresis band current controller. MATLAB/simulink power system toolbox is used to simulate the proposed system. The proposed method restricts both THD and unbalance factor of input currents and a power quality factor is designated which integrally reflects the two quality aspects ( i.e., harmonic and unbalance factor) before and after compensation. Power quality factor improvement with the proposed shunt APLC has been verified by the simulation results.
引用
收藏
页码:411 / 415
页数:5
相关论文
共 50 条
  • [21] Fuzzy logic controlled shunt active power filter for power quality improvement
    Jain, SK
    Agrawal, P
    Gupta, HO
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2002, 149 (05): : 317 - 328
  • [22] Fuzzy based unified power quality conditioner for power quality improvement
    Suja, K.R.
    Jacob Raglend, I.
    Proceedings of IEEE International Conference on Circuit, Power and Computing Technologies, ICCPCT 2013, 2013, : 49 - 52
  • [23] Fuzzy Based Unified Power Quality Conditioner for Power Quality Improvement
    Suja, K. R.
    Raglend, I. Jacob
    PROCEEDINGS OF 2013 INTERNATIONAL CONFERENCE ON CIRCUITS, POWER AND COMPUTING TECHNOLOGIES (ICCPCT 2013), 2013, : 49 - 52
  • [24] PEORMANCE ANALYSIS OF UNIFIED POWER QUALITY CONDITIONER FOR POWER QUALITY IMPROVEMENT
    Saravanan, R.
    Manoharan, P. S.
    ADVANCEMENTS IN AUTOMATION AND CONTROL TECHNOLOGIES, 2014, 573 : 690 - +
  • [25] The working area of the Unified Power Quality Conditioner for Power Quality Improvement
    Fabijanski, Piotr
    PRZEGLAD ELEKTROTECHNICZNY, 2019, 95 (02): : 51 - 54
  • [26] An Unified Power Quality Conditioner for Load Sharing and Power Quality Improvement
    Kwan, Kian Hoong
    Tan, Kuan Tak
    So, Ping Lam
    2012 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2012, : 963 - 967
  • [27] The unified power quality conditioner: The integration of series- and shunt-active filters
    Fujita, H
    Akagi, H
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 1998, 13 (02) : 315 - 322
  • [28] Performance Evaluation of a Three Phase Shunt Active Power Filter For Power Quality Improvement
    Farooq, Anha
    Bhat, Abdul Hamid
    2015 INTERNATIONAL CONFERENCE ON RECENT DEVELOPMENTS IN CONTROL, AUTOMATION AND POWER ENGINEERING (RDCAPE), 2015, : 214 - 219
  • [29] Active power line conditioner with battery charge
    Yamnenko, Yu S.
    Tereshchenko, T.O.
    Mykolayets, D.A.
    Technical Electrodynamics, 2015, 2015 (05): : 16 - 20
  • [30] Power Quality Improvement Based on Shunt Active Power Filter Connected to a Photovoltaic Array
    Belaidi, Rachid
    Fathi, Mohamed
    Larafi, Mohamed Mghezzi
    Kaci, Gunia Mohand
    Belaidi, Rachid