The influence of BRDF calibration to CT industry NDT

被引:0
|
作者
Liu Zilong [1 ]
Liao Ningfang [1 ]
机构
[1] Beijing Inst Technol, Beijing 100081, Peoples R China
关键词
Computed Tomography; BRDF; traceability and calibration; optimized arithmetic model;
D O I
10.1117/12.868317
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Computed Tomography (CT) testing is an important non-destructive testing technology in industry inspection. So the important work of CT development is the value calibration and the precise result judgment. Bi-directional reflection distribution function(BRDF) as the common spatial characteristic parameter can be fit for the CT data structure in theory level and the CT data cube can be calibrated using BRDF in both spectral and spatial. Deferent processing calibrated images can be achieved by calibrating CT data in deferent dynamic range using corresponding BRDF absolute value. Thus the influence of BRDF calibration to CT data can be achieved from these serial calibration data and the optimized arithmetic model for this calibration is established. Furthermore, the uncertainty of this value traceability and calibration is analyzed and a corresponding example in CT industry NDT is given which illustrate that this calibration is useful in analysis of PT image because it provide more true image and reduce the probability of error judgment.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] NDT IN THE NUCLEAR INDUSTRY
    ROGERSON, A
    BRITISH JOURNAL OF NON-DESTRUCTIVE TESTING, 1992, 34 (03): : 117 - 122
  • [2] NDT in the turbine industry
    Broddegard, M.
    Insight: Non-Destructive Testing and Condition Monitoring, 1997, 39 (09): : 616 - 617
  • [3] NDT in the Power Industry
    Selby, Greg
    MATERIALS EVALUATION, 2010, 68 (07) : 763 - 763
  • [4] NDT in the turbine industry
    Broddegard, M
    INSIGHT, 1997, 39 (09) : 616 - 617
  • [5] Seeing the NDT Industry
    Moes, Nat
    MATERIALS EVALUATION, 2012, 70 (06) : 595 - 595
  • [6] NDT in the steel industry
    Knox, TJ
    INSIGHT, 1999, 41 (12) : 781 - 783
  • [7] Shaping the NDT Industry
    Bereson, Arnold Arny
    MATERIALS EVALUATION, 2018, 76 (08) : 1019 - 1020
  • [8] Instrument for retrieval of BRDF data for vicarious calibration
    Nandy, P
    Thome, K
    Biggar, S
    IGARSS '98 - 1998 INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, PROCEEDINGS VOLS 1-5: SENSING AND MANAGING THE ENVIRONMENT, 1998, : 562 - 564
  • [9] Improved MODIS BRDF radiometric calibration approach
    Yan, Li
    Wang, Ying
    Xu, Yaming
    Wuhan Daxue Xuebao (Xinxi Kexue Ban)/Geomatics and Information Science of Wuhan University, 2004, 29 (09):
  • [10] NDT in the Swedish aerospace industry
    Gryback, T
    Brander, L
    Wickstrom, P
    INSIGHT, 1997, 39 (03) : 164 - &