Experience of operating a solar parabolic trough direct steam generation power plant with superheating

被引:14
|
作者
Willwerth, Lisa [1 ]
Feldhoff, Jan Fabian [2 ,6 ]
Krueger, Dirk [1 ]
Keller, Lothar [3 ]
Eickhoff, Martin [3 ]
Krueger, Joachim [4 ]
Pandian, Yuvaraj [4 ]
Tiedemann, Joerg [5 ]
Succo, Manuel [5 ]
Khenissi, Abdallah [2 ,7 ]
机构
[1] German Aerosp Ctr, D-51147 Cologne, Germany
[2] German Aerosp Ctr, Wankelstr 5, D-70563 Stuttgart, Germany
[3] German Aerosp Ctr, Plataforma Solar Almeria, Ctra Senes S-N,Km 4, Tabernas 04200, Spain
[4] Solarlite CSP Technol GmbH, D-17179 Duckwitz, Germany
[5] Tiede & Niemann Ingn Gesell mbH, Harburger Schlossstr 6-12, D-21079 Hamburg, Germany
[6] SWU Stadtwerke Ulm Neu Ulm GmbH, Karlstr 1-3, D-89073 Ulm, Germany
[7] BP 71 Poste Hessi Jerbi, Zarzis 4174, Tunisia
关键词
CSP; Concentrated solar power; DSG; Direct steam generation; Evaporator control; Superheater control; LINE FOCUS SYSTEMS;
D O I
10.1016/j.solener.2018.06.089
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
TSE1 is the first solar thermal power plant operating in Southeast Asia. It was planned by Solarlite GmbH with support of Tiede- & Niemann GmbH, both German based. It is the first power plant with direct steam generation (DSG) concept and superheating in parabolic troughs. The solar field has a nominal power of 19 MWth driving a 5 MWel turbine by superheated steam at 30 bar and 330 degrees C. During 2010/2011 Solarlite built the solar field, while the later owner and operator Thai Solar Energy (TSE) from Bangkok built the power block, in Kanchanaburi, Thailand. TSE1 is being operated by TSE since January 2012 (Kruger et al., 2012). This publication is based on a study within the KanDis project, funded by the German Federal Ministry for Economic Affairs and Energy, in which an extensive database of records of almost 500 sensors installed in the power plant (solar field and power block) has been investigated. The data have been provided by Solarlite with a time resolution of about 1 min. Within the KanDis project, a stable operation could be demonstrated (Khenissi et al., 2015; Kruger et al., 2016). Even under the fluctuating irradiance conditions in the rainy season of Thailand, the turbine could be operated well and generate electricity. Evaluation of the operation data has helped to learn more about DSG behaviour. The TSE1 layout and the implemented control strategies were evaluated and strategies for improvement of TSE1 are suggested within this paper. From the experiences with the TSE1 power plant, conclusions could be drawn to improve the layout and control of future DSG plants.
引用
收藏
页码:310 / 319
页数:10
相关论文
共 50 条
  • [31] Assessing parabolic trough collectors and linear Fresnel reflectors direct steam generation solar power plants in Northwest México
    Gonzalez-Mora, Eduardo
    Duran-Garcia, Ma. Dolores
    RENEWABLE ENERGY, 2024, 228
  • [32] Direct steam generation in parabolic trough solar power plants: Numerical investigation of the transients and the control of a once-through system
    Lippke, F
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (01): : 9 - 14
  • [33] Solar-assisted steam power plant retrofitted with regenerative system using Parabolic Trough Solar Collectors
    Alotaibi, Sorour
    Alotaibi, Fahad
    Ibrahim, Osama M.
    ENERGY REPORTS, 2020, 6 (124-133) : 124 - 133
  • [34] Performance analysis of an Integrated Solar Combined Cycle using Direct Steam Generation in parabolic trough collectors
    Montes, M. J.
    Rovira, A.
    Munoz, M.
    Martinez-Val, J. M.
    APPLIED ENERGY, 2011, 88 (09) : 3228 - 3238
  • [35] Thermal transfer performance and flow instability analysis of direct steam generation for parabolic trough solar collectors
    Liu, Shuaishuai
    Yang, Bin
    Yu, Xiaohui
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2025, 208
  • [36] Thermo-hydraulic analysis and numerical simulation of a parabolic trough solar collector for direct steam generation
    Hachicha, Ahmed Amine
    Rodriguez, Ivette
    Ghenai, Chaouki
    APPLIED ENERGY, 2018, 214 : 152 - 165
  • [37] Nonlinear distributed parameter model and dynamic characteristics of parabolic trough direct steam generation solar collectors
    College of Energy and Environment, Southeast University, Nanjing 210096, Jiangsu Province, China
    不详
    Guo, S. (guosu81@126.com), 1779, Chinese Society for Electrical Engineering (34):
  • [38] Alternative Approach for Thermo-Hydraulic Modeling of Direct Steam Generation in Parabolic Trough Solar Collectors
    Gonzalez-Mora, Eduardo
    Duran-Garcia, M. Dolores
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2024, 16 (05)
  • [39] Flow field optimization for the solar parabolic trough receivers in direct steam generation systems by the variational principle
    Liu, Yun
    Chen, Qun
    Hu, Kang
    Hao, Jun-Hong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 102 : 1073 - 1081
  • [40] Transient characteristics of a parabolic trough direct-steam generation process
    Li, Lu
    Sun, Jie
    Li, Yinshi
    He, Ya-Ling
    Xu, Haojie
    RENEWABLE ENERGY, 2019, 135 : 800 - 810