Dynamic thermal performance analysis for fin-concrete ceiling in main control rooms of passive nuclear power plants

被引:5
|
作者
Huang, Yixiang [1 ]
Su, Xing [1 ]
Wu, Xiaoyan [1 ,2 ]
Ye, Wei [1 ,3 ]
Zhang, Xu [1 ]
机构
[1] Tongji Univ, Sch Mech Engn, Shanghai 200092, Peoples R China
[2] Jiaxing Univ, Coll Civil Engn & Architecture, Jiaxing 314001, Peoples R China
[3] Tongji Univ, Minist Educ, Key Lab Performance Evolut & Control Engn Struct, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Dynamic thermal performance; Passive cooling; Finned concrete; Thermal network model; COOLING SYSTEM; HEAT-PIPE; SIMULATION; INLEAKAGE; DESIGN; EXCHANGER;
D O I
10.1016/j.csite.2021.101402
中图分类号
O414.1 [热力学];
学科分类号
摘要
The main control rooms of passive nuclear plants must maintain a habitable environment once station-blackout accidents occur. In this condition, the heavy fin-concrete ceiling on the room will remove heat from kind of heat sources and protect from overheating environment. However, the dynamic thermal process of finned concrete ceiling has not been studied in various passive cooling measures. In this study, an efficient parametric resistance-capacitance thermal network model is established to describe dynamic thermal responses of heavy fin-concrete layer, and validated by dynamic temperature change data of a hot-box experiment for 24 h. Series indicators were deduced by analytic solutions. Based on the validated model and indicators, factor analysis was conducted to obtain details of effect of finned-plate geometric parameters and heat source intensity. The results show that initial 2-h thermal process can be divided into two stage, "transient stage" and "quasi-stable stage". The transient-stage thermal process is determined by source flux and finned coefficient of finned plate. The quasi-stable thermal process depends on thermal mass of the finned plate and heat source flux. Furthermore, there exists a linear relationship between air temperature and heat source flux. Finned plate layout can be design according to the factor assessment results.
引用
收藏
页数:16
相关论文
共 32 条
  • [11] Design and analysis of new prestressed concrete containment and its passive cooling system for nuclear power plants
    Tan, Xiao-Shi
    Li, Xiao-Wei
    Li, Xiao-Tian
    He, Shu-Yan
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2014, 48 (02): : 271 - 276
  • [12] APPLICATION OF MONITORING, DIAGNOSIS, AND PROGNOSIS IN THERMAL PERFORMANCE ANALYSIS FOR NUCLEAR POWER PLANTS
    Kim, Hyeonmin
    Na, Man Gyun
    Heo, Gyunyoung
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2014, 46 (06) : 737 - 752
  • [13] Performance Analysis of Water Heat Pipe for Application of the Passive Cooling System in Nuclear Power Plants
    Park, Ye Yeong
    Bang, In Cheol
    NUCLEAR TECHNOLOGY, 2024,
  • [14] EXPERIMENTAL ANALYSIS OF DYNAMIC OPERATIONS OF THE MAIN STEAM RELIEF ISOLATION VALVE USED IN NUCLEAR POWER PLANTS
    Zhou, Weihao
    Zong, Chaoyong
    Li, Qingye
    Jiang, Songzhi
    Liu, Yanliang
    Song, Xueguan
    PROCEEDINGS OF ASME 2023 PRESSURE VESSELS & PIPING CONFERENCE, PVP2023, VOL 6, 2023,
  • [15] Dynamic Modeling and Analysis of the Main Steam Relief Isolation Valve (MSRIV) Used in Nuclear Power Plants
    Zong, Chaoyong
    Li, Qingye
    Peng, Yue
    Yang, Guanghong
    Zhou, Weihao
    Xiao, Jian
    Song, Xueguan
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2024, 60 (20): : 339 - 350
  • [16] PERFORMANCE ANALYSIS OF EDUCTOR USED FOR MAIN CONTROL ROOM VENTILATING IN NUCLEAR POWER PLANT
    Yu, Xin
    Lin, Yuqing
    Zhang, Yan
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 2, 2017,
  • [17] Research on Stability Analysis and Guaranteed Performance Control of Networked Control System in Nuclear Power Plants
    Tao, Mo
    Wang, Chenyang
    Ke, Zhiwu
    Guo, Xiaojie
    Zheng, Wei
    Zhou, Hongkuan
    Chai, Wenting
    Feng, Yi
    Sun, Quqin
    PROCEEDINGS OF 2022 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2022), 2022, : 1393 - 1397
  • [18] A Fuzzy CREAM Method for Human Reliability Analysis in Digital Main Control Room of Nuclear Power Plants
    Yao, Kai
    Yan, Shengyuan
    Tran, Cong Chi
    NUCLEAR TECHNOLOGY, 2022, 208 (04) : 761 - 774
  • [19] Failure Analysis and Reliability Improvement of Control System of Main Steam Isolation Valve in Nuclear Power Plants
    Li X.
    Hedongli Gongcheng/Nuclear Power Engineering, 2021, 42 (01): : 138 - 142
  • [20] MARKOV/CCMT DYNAMIC RELIABILITY ANALYSIS OF THE MAIN AND STARTUP FEEDWATER CONTROL SYSTEM IN NUCLEAR POWER PLANT
    Li, Wentao
    Gu, Danying
    Zhang, Henan
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 1, 2017,