Monitoring and Dispersion Modeling of Polybrominated Diphenyl Ethers (PBDEs) in the Ambient Air of Two Municipal Solid Waste Incinerators and a Coal-fired Power Plant

被引:14
|
作者
Tu, Li-Kai [3 ,4 ]
Wu, Yee-Lin [3 ,4 ]
Wang, Lin-Chi [1 ,2 ]
Chang-Chien, Guo-Ping [1 ,2 ]
机构
[1] Cheng Shiu Univ, Dept Chem & Mat Engn, Kaohsiung 833, Taiwan
[2] Cheng Shiu Univ, Super Micro Mass Res & Technol Ctr, Kaohsiung 833, Taiwan
[3] Natl Cheng Kung Univ, Dept Environm Engn, Tainan 70101, Taiwan
[4] Natl Cheng Kung Univ, Sustainable Environm Res Ctr, Tainan 70101, Taiwan
关键词
Polybrominated diphenyl ethers (PBDEs); Municipal solid waste incinerators; Coal-fired power plant; Stack flue gases; Dispersion; BROMINATED FLAME RETARDANTS; DIBENZO-P-DIOXINS; CENTRAL TAIWAN; HUMAN EXPOSURE; HUMAN-MILK; EMISSIONS; IDENTIFICATION; PERSPECTIVE; CONSUMPTION; COMBUSTION;
D O I
10.4209/aaqr.2011.09.0152
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The concentration of polybrominated diphenyl ethers (PBDEs) in the ambient air of two municipal solid waste incinerators (MSWIs) and one coal-fired power plant (TPP) were determined. Along with the sites mentioned above, eight ambient air samples were collected. Cluster analysis was carried out to determine the relationship of PBDE characteristics between each site. Finally, PBDE dispersion modeling in the atmosphere was applied by using ISCST3 (Industrial Source Complex Short Term 3) to assess the impact of the above two municipal solid waste incinerators and one coal-fired power plant on the ambient air. The total-PBDE concentrations in the ambient air were between 24.9 and 139 pg/Nm(3), averaging 59.8 pg/Nm(3) (n = 16). The BDE-209, BDE-47 and BDE-207 were the most predominant three among all 30 PBDE congeners, which contributed more than 58%, 9%, and 4% of total-PBDE mass to the ambient air, respectively. The results of cluster analysis indicated that no direct correlations existed among the emission sources (MSWI-A, MSWI-B, TPP) and the receptors (sampling sites). From the results of dispersion modeling, the annual total PBDE concentration in ambient air contributed by the MSWI-A, MSWI-B, TPP together were found to be 0.0259% +/- 0.0208%. Hence, the results of both cluster analysis and dispersion modeling showed that MWSI-A, MSWI-B, and TPP were definitely not the major contributors of PBDEs to the ambient air environment. The ashes collected from the air pollution control devices of both the MSWIs and the TPP are probably a more important environmental issue and therefore should be paid more attention to.
引用
收藏
页码:113 / 122
页数:10
相关论文
共 41 条
  • [1] Distribution of Polybrominated Dibenzo-p-dioxins and Dibenzofurans and Polybrominated Diphenyl Ethers in a Coal-fired Power Plant and Two Municipal Solid Waste Incinerators
    Tu, Li-Kai
    Wu, Yee-Lin
    Wang, Lin-Chi
    Chang-Chien, Guo-Ping
    AEROSOL AND AIR QUALITY RESEARCH, 2011, 11 (05) : 596 - 615
  • [2] The Emission and Distribution of PCDD/Fs in Municipal Solid Waste Incinerators and Coal-fired Power Plant
    Lin, Wen-Yinn
    Wu, Yee-Lin
    Tu, Li-Kai
    Wang, Lin-Chi
    Lu, Xin
    AEROSOL AND AIR QUALITY RESEARCH, 2010, 10 (06) : 519 - 532
  • [3] Distribution of polybrominated diphenyl ethers (PBDEs) and polybrominated dibenzo-p-dioxins and dibenzofurans (PBDD/Fs) in municipal solid waste incinerators
    Wang, Lin-Chi
    Hsi, Hsing-Cheng
    Wang, Ya-Fen
    Lin, Sheng-Lun
    Chang-Chien, Guo-Ping
    ENVIRONMENTAL POLLUTION, 2010, 158 (05) : 1595 - 1602
  • [4] Polybrominated diphenyl ethers (PBDES) at a solid waste incineration plant I: Atmospheric concentrations
    Agrell, C
    ter Schure, AFH
    Sveder, J
    Bokenstrand, A
    Larsson, P
    Zegers, BN
    ATMOSPHERIC ENVIRONMENT, 2004, 38 (30) : 5139 - 5148
  • [5] Polybrominated diphenyl ethers (PBDEs) in ambient air samples at the electronic waste (e-waste) reclamation site
    Ghimire, Ajit
    dela Cruz, Albert Leo N.
    Wong, Roberto
    Cormier, Stephania
    Navasumrit, Panida
    Lomnicki, Slawomir M.
    WASTE DISPOSAL & SUSTAINABLE ENERGY, 2019, 1 (01) : 79 - 89
  • [6] Polybrominated diphenyl ethers (PBDEs) in ambient air samples at the electronic waste (e-waste) reclamation site
    Ajit Ghimire
    Albert Leo N. dela Cruz
    Roberto Wong
    Panida Navasumrit
    Stephania Cormier
    Slawomir M. Lomnicki
    Waste Disposal & Sustainable Energy, 2019, 1 : 79 - 89
  • [7] Size distribution and leaching characteristics of poly brominated diphenyl ethers (PBDEs) in the bottom ashes of municipal solid waste incinerators
    Lin, Yi-ming
    Zhou, Shao-qi
    Lee, Wen-Jhy
    Wang, Lin-Chi
    Chang-Chien, Guo-Ping
    Lin, Wei-Chih
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2014, 21 (06) : 4614 - 4623
  • [8] Size distribution and leaching characteristics of poly brominated diphenyl ethers (PBDEs) in the bottom ashes of municipal solid waste incinerators
    Yi-ming Lin
    Shao-qi Zhou
    Wen-Jhy Lee
    Lin-Chi Wang
    Guo-Ping Chang-Chien
    Wei-Chih Lin
    Environmental Science and Pollution Research, 2014, 21 : 4614 - 4623
  • [9] Modeling Radionuclides Dispersion and Deposition Downwind of a Coal-Fired Power Plant
    Dinis, M. L.
    Fiuza, A.
    Gois, J.
    Carvalho, J. M. S.
    Castro, A. C. M.
    URANIUM, ENVIRONMENT AND PUBLIC HEALTH, 2014, 8 : 59 - 63
  • [10] TEM study of fine particles from coal-fired power plant ambient air
    Pian, Wei
    Cheng, Wenjing
    Niu, Hongya
    Fan, Jingsen
    WORLD JOURNAL OF ENGINEERING, 2016, 13 (04) : 311 - 316