Apparent accommodation and depth of field in pseudophakia

被引:54
|
作者
Elder, MJ
Murphy, C
Sanderson, GF
机构
[1] Ophthalmology Department, Christchurch Hospital, Christchurch
来源
关键词
D O I
10.1016/S0886-3350(96)80020-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess depth of field in phakic and pseudophakic eyes to explain good distance and uncorrected near visual acuity in pseudophakic eyes. Setting: Department of Ophthalmology, University of Otago Medical School, Dunedin, New Zealand. Methods: Depth of field was measured in pseudophakic (n = 10) and phakic (n = 10) eyes for both near and distant targets. Test conditions included cycloplegia and a constant pupillary aperture using a soft contact lens with a central artificial pupil diameter of 2.5 mm. Results: There was no statistically significant difference between phakic and pseudophakic eyes for any test. Depth of field for near visual acuity was +/-0.85 diopters (D), but amplitude of legibility was +/- 1.94 D. Depth of field for distance visual acuity was between 0.25 and 0.50 D in 85% of eyes. Conclusion: In the absence of astigmatism and disease, a pseudophakic eye with -0.75 D of myopia can expect to achieve 20/30 uncorrected distance acuity and read N5 unaided if the pupil is approximately 2.5 mm.
引用
收藏
页码:615 / 619
页数:5
相关论文
共 50 条
  • [31] Apparent depth of picture in mirror
    Higashiyama, A.
    Shimono, K.
    PERCEPTION, 2010, 39 : 73 - 73
  • [32] APPARENT DEPTH AND THE VIRTUAL CAUSTIC
    BAEZ, AV
    AMERICAN JOURNAL OF PHYSICS, 1946, 14 (01) : 45 - 47
  • [33] SUBJECTIVE CONTOURS AND APPARENT DEPTH
    COREN, S
    PSYCHOLOGICAL REVIEW, 1972, 79 (04) : 359 - &
  • [34] APPARENT MOTION IN GEOMETRIC DEPTH
    WIENKE, RE
    STEEDMAN, WC
    HUMAN FACTORS, 1965, 7 (03) : 215 - 218
  • [35] Effect of Pseudophakia on Central Visual Field in Patients With Retinitis Pigmentosa
    Jingami, Y.
    Otani, A.
    Nakagawa, S.
    Kojima, H.
    Kurimoto, M.
    Ogino, K.
    Yoshimura, N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [36] APPARENT IMAGE QUALITY OF MAGNIFIERS DEPENDS ON AMPLITUDE OF ACCOMMODATION
    KATZ, M
    ZIKOS, G
    OPTOMETRY AND VISION SCIENCE, 1994, 71 (03) : 226 - 234
  • [37] Apparent accommodation after cataract extraction in pediatric patients
    January, B
    Drack, AV
    Williams, K
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 3510 - 3510
  • [38] THE APPARENT IMAGE QUALITY OF MAGNIFIERS DEPENDS ON AMPLITUDE OF ACCOMMODATION
    KATZ, M
    ZIKOS, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 791 - 791
  • [39] Apparent accommodation and corneal wavefront aberration in pseudophakic eyes
    Oshika, T
    Mimura, T
    Tanaka, S
    Amano, S
    Fukuyama, M
    Yoshitomi, F
    Maeda, N
    Fujikado, T
    Hirohara, Y
    Mihashi, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (09) : 2882 - 2886
  • [40] APPARENT SIZE, APPARENT DEPTH AND MULLER-LYER ILLUSION
    STACEY, B
    PIKE, R
    PERCEPTION & PSYCHOPHYSICS, 1970, 7 (02): : 125 - &