Removal of Urea, β2-Microglobulin, and Indoxyl Sulfate Assessed by Absorbance and Fluorescence in the Spent Dialysate During Hemodialysis

被引:10
|
作者
Lauri, Kai [1 ,2 ]
Arund, Jurgen [1 ]
Holmar, Jana [1 ,3 ]
Tanner, Risto [1 ]
Kalle, Sigrid [1 ]
Luman, Merike [1 ,4 ]
Fridolin, Ivo [1 ]
机构
[1] Tallinn Univ Technol, Dept Hlth Technol, Ehitajate Rd 5, EST-19086 Tallinn, Estonia
[2] SYNLAB Eesti Ou, Tallinn, Estonia
[3] RWTH Aachen Univ Hosp, Inst Mol Cardiovasc Res IMCAR, Aachen, Germany
[4] North Estonian Med Ctr, Ctr Nephrol, Tallinn, Estonia
关键词
dialysis; dialysis adequacy; uremic toxins; uremic retention solutes; optical monitoring; ultraviolet absorbance; fluorescence; GLYCATION END-PRODUCTS; ULTRAVIOLET-ABSORBENCY; UV-ABSORBENCY; UREMIC TOXINS; URIC-ACID; ONLINE; SOLUTES; SERUM; HEMODIAFILTRATION; QUANTIFICATION;
D O I
10.1097/MAT.0000000000001058
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, simultaneous removal assessment of marker molecules from three uremic toxin groups was performed during different hemodialysis treatment modalities using optical characteristics of spent dialysate. Results from optical measurements were compared with the results from chemical laboratory. Ten chronic dialysis patients, mean age 59 +/- 15 years, were included in the study during 40 hemodialysis sessions. Low-flux hemodialysis (HD), high-flux hemodialysis (HF), and postdilutional online hemodiafiltration (HDF) with different settings were used. The reduction ratio (RR) and total removed solute (TRS) of three uremic solutes were determined: small molecular weight urea, middle molecular beta 2-microglobulin (B2M), and protein-bound indoxyl sulfate (IS). Concentrations of these solutes in the spent dialysate were measured by laboratory (lab) and optical (opt) methods, in the serum by laboratory methods, and calculated RR values in percentage were compared accordingly. Total removed solute was obtained from the total dialysate collection (TDC) using lab and opt methods. The highest RR values were found for urea and B2M, and the lowest for IS. The difference between RR of lab and opt results estimated as mean accuracy (BIAS) was <= 8.1% for all three solutes. Good correspondence between TRS lab vs. opt was achieved, resulting in strong linear correlation values R from 0.727 for urea to 0.971 for IS. Accuracy for TRS values as BIAS +/- standard error (SE), comparing lab vs. opt, showed no statistical difference for any of the observed uremic solutes (P > 0.05). The accuracy of the optical method was not influenced by the dialysis modality (HD, HF, and HDF).
引用
收藏
页码:698 / 705
页数:8
相关论文
共 34 条
  • [1] The Removal of β2-Microglobulin in Spent Dialysate Cannot Be Monitored by Spectrophotometric Analysis
    Donadio, Carlo
    Calia, Dario
    Ghimenti, Silvia
    Onor, Massimo
    Colombini, Elisa
    Fuoco, Roger
    Di Francesco, Fabio
    [J]. BLOOD PURIFICATION, 2015, 40 (02) : 109 - 112
  • [2] Kinetics of urea and β2-microglobulin during and after short hemodialysis treatments
    Leypoldt, JK
    Cheung, AK
    Deeter, RB
    Goldfarb-Rumyantzev, A
    Greene, T
    Depner, TA
    Kusek, J
    [J]. KIDNEY INTERNATIONAL, 2004, 66 (04) : 1669 - 1676
  • [3] Fluorescence of Beta-2-microglobulin in the Spent Dialysate
    Kalle, S.
    Kressa, H.
    Tanner, R.
    Holmar, J.
    Fridolin, I.
    [J]. 16TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING, 2015, 48 : 59 - 62
  • [4] β2-microglobulin removal by hemodialysis with polymethylmethacrylate membranes
    Campistol, JM
    Torregrosa, JV
    Ponz, E
    Fenollosa, B
    [J]. POLYMETHYLMETHACRYLATE A FLEXIBLE MEMBRANE FOR A TAILORED DIALYSIS, 1999, 125 : 76 - 85
  • [5] Online measurement of urea concentration in spent dialysate during hemodialysis
    Olesberg, JT
    Arnold, MA
    Flanigan, MJ
    [J]. CLINICAL CHEMISTRY, 2004, 50 (01) : 175 - 181
  • [6] Online measurement of urea concentration in spent dialysate during hemodialysis
    Olesberg, JT
    Armitage, B
    Arnold, MA
    Flanigan, MJ
    [J]. OPTICAL DIAGNOSTICS AND SENSING OF BIOLOGICAL FLUIDS AND GLUCOSE AND CHOLESTEROL MONITORING II, 2002, 4624 : 95 - 105
  • [7] INTERRELATIONSHIP BETWEEN PROTEIN BOUND UREMIC TOXIN INDOXYL SULFATE CONCENTRATION IN BLOOD AND SPENT DIALYSATE DURING HEMODIALYSIS TREATMENT
    Paats, Joosep
    Adoberg, Annika
    Arund, Jurgen
    Fridolin, Ivo
    Lauri, Kai
    Leis, Liisi
    Pilt, Kristjan
    Tanner, Risto
    Luman, Merike
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2021, 36
  • [8] Ultrapure dialysate reduces plasma levels of β2-microglobulin and pentosidine in hemodialysis patients
    Furuya, R
    Kumagai, H
    Takahashi, M
    Sano, K
    Hishida, A
    [J]. BLOOD PURIFICATION, 2005, 23 (04) : 311 - 316
  • [9] Estimating total urea removal and protein catabolic rate by monitoring UV absorbance in spent dialysate
    Uhlin, F
    Fridolin, I
    Lindberg, LG
    Magnusson, M
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2005, 20 (11) : 2458 - 2464
  • [10] Iron induced modifications of beta 2-microglobulin affect its removal during hemodialysis
    Sela, S
    Michelis, R
    Kristal, B
    [J]. FREE RADICAL BIOLOGY AND MEDICINE, 2003, 35 : S135 - S135