Influence of atomic force microscope cantilever tilt and induced torque on force measurements

被引:42
|
作者
Edwards, Scott A. [1 ]
Ducker, William A. [2 ]
Sader, John E. [1 ]
机构
[1] Univ Melbourne, Dept Math & Stat, Melbourne, Vic 3010, Australia
[2] Univ Melbourne, Dept Chem & Biomol Engn, Melbourne, Vic 3010, Australia
关键词
D O I
10.1063/1.2885734
中图分类号
O59 [应用物理学];
学科分类号
摘要
Quantitative force measurements performed using the atomic force microscope (AFM) inherently rely on calibration of the AFM cantilever spring constant to convert the measured deflection into a force. Here, we examine the effect of cantilever tilt and induced torque on the effective normal spring constant resulting from variable placement of the tip probe, as is frequently encountered in practice. Explicit general formulas are presented that account for these combined effects for both sharp tips and spherical probes. In contrast to previous studies, we find that induced tip torque can act to either enhance or reduce the effective normal spring constant of the cantilever. The implications of this study to practical force measurements are discussed. c 2008 American Institute of Physics.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Influence of atomic force microscope cantilever tilt and induced torque on force measurements
    Edwards, Scott A.
    Ducker, William A.
    Sader, John E.
    Journal of Applied Physics, 2008, 103 (06):
  • [2] Comment on "Influence of atomic force microscope cantilever tilt and induced torque on force measurements" [J. Appl. Phys. 103, 064513 (2008)]
    Wang, Fei
    JOURNAL OF APPLIED PHYSICS, 2009, 106 (09)
  • [3] Experimental confirmation of the atomic force microscope cantilever stiffness tilt correction
    Gates, Richard S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (12):
  • [4] SHAPE OF THE CANTILEVER DEFLECTION FOR THE ATOMIC-FORCE MICROSCOPE IN FORCE CURVE MEASUREMENTS
    SASAKI, M
    HANE, K
    OKUMA, S
    BESSHO, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (06): : 1930 - 1934
  • [5] Reconstructing the distributed force on an atomic force microscope cantilever
    Wagner, Ryan
    Killgore, Jason
    NANOTECHNOLOGY, 2017, 28 (10)
  • [6] Tilt of atomic force microscope cantilevers: Effect on friction measurements
    Wang, Fei
    Zhao, Xuezeng
    PROGRESSES IN FRACTURE AND STRENGTH OF MATERIALS AND STRUCTURES, 1-4, 2007, 353-358 : 742 - 745
  • [7] Lorentz force actuation of a heated atomic force microscope cantilever
    Lee, Byeonghee
    Prater, Craig B.
    King, Andwilliam P.
    NANOTECHNOLOGY, 2012, 23 (05)
  • [8] Lateral force microscope calibration using a modified atomic force microscope cantilever
    Reitsma, M. G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (10):
  • [9] Biomolecular force measurements and the atomic force microscope
    Allison, DP
    Hinterdorfer, P
    Han, WH
    CURRENT OPINION IN BIOTECHNOLOGY, 2002, 13 (01) : 47 - 51
  • [10] SCANNED-CANTILEVER ATOMIC FORCE MICROSCOPE
    BASELT, DR
    BALDESCHWIELER, JD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (04): : 908 - 911