Biosensors based on acrylic microgels -: A comparative study of immobilized glucose oxidase and tyrosinase

被引:28
|
作者
Retama, JR
López, ASP
Pérez, JPH
Cabanillas, GF
López-Cabarcos, E
López-Ruiz, B
机构
[1] Univ Complutense, Fac Farm, Dept Quim Analit, E-28040 Madrid, Spain
[2] Univ Complutense, Fac Farm, Dept Quim Fis Farmaceut, E-28040 Madrid, Spain
[3] Univ Complutense, Fac Farm, Dept Estadist & Invest Operat, E-28040 Madrid, Spain
来源
BIOSENSORS & BIOELECTRONICS | 2005年 / 20卷 / 11期
关键词
amperometric biosensor; glucose oxidase; tyrosinase; experimental design;
D O I
10.1016/j.bios.2004.10.011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Acrylic microgels are proposed as enzyme immobilizing support in amperometric biosensors. Two enzymes, glucose oxidase and tyrosinase, were entrapped in this matrix and their behaviour is compared. The optimum cross-linking of the polymeric matrix required to retain the enzyme, and to allow the diffusion of the substrate is different for each enzyme, 3.2% for glucose oxidase and 4.5% for tyrosinase. The effect of pH and temperature on the biosensor responses has been studied by experimental design methodology and predictions have been compared with independently performed experimental measurements. A quadratic effect of the variables studied (pH and 7) on the biosensor response and the small or null interaction between them was confirmed. The pH results obtained with both methods are coincident revealing an reversible effect on the enzyme. However, the temperature optimum value obtained by experimental design was 10 degrees C lower as a result of an activity decay due to irreversible thermal denaturation of both enzymes. (c) 2004 Elsevier B.V All rights reserved.
引用
收藏
页码:2268 / 2275
页数:8
相关论文
共 50 条
  • [21] Frequency response of the glucose sensor based on immobilized glucose oxidase membrane
    Gondo, S
    Kim, C
    Morishita, M
    Kawakami, M
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1996, 57-8 : 877 - 884
  • [22] Immobilization of glucose oxidase on magnetite particles modified by grafting acrylic acid-acrylamide copolymer - Effect of pH on activity of immobilized glucose oxidase
    Shimomura, M
    Togashi, R
    Oshima, K
    Yamauchi, T
    Miyauchi, S
    KOBUNSHI RONBUNSHU, 2004, 61 (02) : 133 - 138
  • [23] An optical glucose biosensor based on glucose oxidase immobilized on a swim bladder membrane
    Zaide Zhou
    Lina Qiao
    Peng Zhang
    Dan Xiao
    Martin M. F. Choi
    Analytical and Bioanalytical Chemistry, 2005, 383 : 673 - 679
  • [24] DETERMINATION OF GLUCOSE IN ENZYMATIC ANALYZER BASED ON MINIREACTORS WITH IMMOBILIZED GLUCOSE-OXIDASE
    KOVALENKO, GA
    SOKOLOVSKII, VD
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1989, 44 (07): : 1082 - 1086
  • [25] AMPEROMETRIC GLUCOSE SENSORS BASED ON IMMOBILIZED GLUCOSE-OXIDASE POLYQUINONE SYSTEM
    KAKU, T
    KARAN, HI
    OKAMOTO, Y
    ANALYTICAL CHEMISTRY, 1994, 66 (08) : 1231 - 1235
  • [26] Glucose oxidase immobilized macro porous silicon based conductive glucose sensor
    Tanusree Sarkar
    Nandini Mukherjee
    Jayoti Das
    Applied Physics A, 2022, 128
  • [27] Enhanced adsorption of glucose oxidase by introducing artificial porosity into polypyrrole based glucose biosensors
    Ekanayake, E. M. I. Mala
    Preethichandra, D. M. G.
    Kaneto, K.
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 1348 - 1351
  • [28] Glucose microfluidic biosensors based on immobilizing glucose oxidase in poly(dimethylsiloxane) electrophoretic microchips
    Zhang, Qing
    Xu, Jing-Juan
    Chen, Hong-Yuan
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1135 (01) : 122 - 126
  • [29] Glucose oxidase immobilized macro porous silicon based conductive glucose sensor
    Sarkar, Tanusree
    Mukherjee, Nandini
    Das, Jayoti
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2022, 128 (04):
  • [30] Glucose sensors based on glucose oxidase immobilized in polypyrrole-polyacrylamide microparticles
    López-Cabarcos, E
    Rubio-Retama, J
    Mecerreyes, D
    López-Ruiz, B
    NSTI NANOTECH 2004, VOL 1, TECHNICAL PROCEEDINGS, 2004, : 236 - 238