Quantitative Analysis of Magnesium in Soil by Laser-Induced Breakdown Spectroscopy Coupled with Nonlinear Multivariate Calibration

被引:23
|
作者
Yongcheng, J. [1 ,2 ]
Wen, S. [1 ]
Baohua, Z. [3 ]
Dong, L. [3 ]
机构
[1] Anhui Univ, Sch Elect Engn & Automat, Hefei 230601, Anhui, Peoples R China
[2] Hefei Univ Technol, Sch Mech & Automot Engn, Hefei 230009, Anhui, Peoples R China
[3] Anhui Univ, Sch Elect & Informat Engn, Hefei 230601, Anhui, Peoples R China
关键词
laser-induced breakdown spectroscopy; soil; magnesium; nonlinear multivariate calibration; RARE-EARTH-ELEMENTS; SAMPLES; LIBS; QUANTIFICATION; DIAGNOSIS; METALS;
D O I
10.1007/s10812-017-0537-9
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Laser-induced breakdown spectroscopy (LIBS) coupled with the nonlinear multivariate regression method was applied to analyze magnesium (Mg) contents in soil. The plasma was generated using a 100 mJ Nd:YAG pulsed laser, and the spectra were acquired using a multi-channel spectrometer integrated with a CCD detector. The line at 383.8 nm was selected as the analysis line for Mg. The calibration model between the intensity of characteristic line and the concentration of Mg was constructed. The traditional calibration curve showed that the concentration of Mg was not only related to the line intensity of itself, but also to other elements in soil. The intensity of characteristic lines for Mg (Mg I 383.8 nm), manganese (Mn) (Mn I 403.1 nm), and iron (Fe) (Fe I 407.2 nm) were used as input data for nonlinear multivariate calculation. According to the results of nonlinear regression, the ternary nonlinear regression was the most appropriate of the studied models. A good agreement was observed between the actual concentration provided by inductively coupled plasma mass spectrometry (ICP-MS) and the predicted value obtained using the nonlinear multivariate regression model. The correlation coefficient between predicted concentration and the measured value was 0.987, while the root mean square error of calibration (RMSEC) and root mean square error of prediction (RMSEP) were reduced to 0.017% and 0.014%, respectively. The ratio of the standard deviation of the validation to the RMSEP increased to 8.79, and the relative error was below 1.21% for nine validation samples. This indicated that the multivariate model can obtain better predicted accuracy than the calibration curve. These results also suggest that the LIBS technique is a powerful tool for analyzing the micro-nutrient elements in soil by selecting calibration and validation samples with similar matrix composition.
引用
收藏
页码:731 / 737
页数:7
相关论文
共 50 条
  • [31] Novel Multivariate Analysis for Soil Carbon Measurements Using Laser-Induced Breakdown Spectroscopy
    Martin, Madhavi Z.
    Labbe, Nicole
    Andre, Nicolas
    Wullschleger, Stan D.
    Harris, Ronny D.
    Ebinger, Michael H.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2010, 74 (01) : 87 - 93
  • [32] Heuristic Methods of Calibration-Free Laser-Induced Breakdown Spectroscopy in Quantitative Analysis
    Zhang, Haibin
    Pan, Congyuan
    Wu, Gang
    PROCEEDINGS OF THE 36TH CHINESE CONTROL CONFERENCE (CCC 2017), 2017, : 5365 - 5371
  • [33] Quantitative analysis of ceramics by laser-induced breakdown spectroscopy
    Kuzuya, M
    Murakami, M
    Maruyama, N
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (05) : 957 - 965
  • [34] Rapid quantitative analysis of magnesium stearate in tablets using laser-induced breakdown spectroscopy
    St-Onge, L
    Archambault, JF
    Kwong, E
    Sabsabi, M
    Vadas, EB
    JOURNAL OF PHARMACY AND PHARMACEUTICAL SCIENCES, 2005, 8 (02): : 272 - 288
  • [35] Compositional analysis of soil using calibration-free laser-induced breakdown spectroscopy
    Israr, Muhammad Aamir
    Abbas, Qamar
    Haq, Sami-ul
    Nadeem, Ali
    SPECTROSCOPY LETTERS, 2022, 55 (05) : 350 - 361
  • [36] A novel strategy for quantitative analysis of soil pH via laser-induced breakdown spectroscopy coupled with random forest
    赵明静
    闫春华
    冯耀州
    薛佳
    汤宏胜
    张天龙
    李华
    Plasma Science and Technology, 2020, 22 (07) : 27 - 33
  • [37] A novel strategy for quantitative analysis of soil pH via laser-induced breakdown spectroscopy coupled with random forest
    赵明静
    闫春华
    冯耀州
    薛佳
    汤宏胜
    张天龙
    李华
    Plasma Science and Technology, 2020, (07) : 27 - 33
  • [38] A novel strategy for quantitative analysis of soil pH via laser-induced breakdown spectroscopy coupled with random forest
    ZHAO, Mingjing
    YAN, Chunhua
    FENG, Yaozhou
    XUE, Jia
    TANG, Hongsheng
    ZHANG, Tianlong
    LI, Hua
    PLASMA SCIENCE & TECHNOLOGY, 2020, 22 (07)
  • [39] Laser-Induced Breakdown Spectroscopy of Steel: A Comparison of Univariate and Multivariate Calibration Methods
    Stipe, Christopher B.
    Hensley, Brian D.
    Boersema, Jeffrey L.
    Buckley, Steven G.
    APPLIED SPECTROSCOPY, 2010, 64 (02) : 154 - 160
  • [40] One-point calibration for calibration-free laser-induced breakdown spectroscopy quantitative analysis
    Cavalcanti, G. H.
    Teixeira, D. V.
    Legnaioli, S.
    Lorenzetti, G.
    Pardini, L.
    Palleschi, V.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 87 : 51 - 56