New factor to improve reliability of the clinical history method for intraocular lens power calculation after refractive surgery

被引:36
|
作者
Rosa, Nicola [1 ,2 ]
De Bernardo, Maddalena [2 ]
Borrelli, Maria [1 ]
Lanza, Michele [1 ,2 ]
机构
[1] Univ Naples 2, Ctr Grandi Apparecchiature, I-80100 Naples, Italy
[2] Univ Naples 2, Eye Dept, I-80100 Naples, Italy
来源
关键词
IN-SITU-KERATOMILEUSIS; REQUIRING CATARACT-SURGERY; CORNEAL POWER; PHOTOREFRACTIVE KERATECTOMY; ORBSCAN-II; EYES; FORMULA; MYOPIA; LASIK; KERATOMETRY;
D O I
10.1016/j.jcrs.2010.07.017
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine whether the refractive error in an eye developing cataract after refractive surgery represents actual regression or is cataract related and whether the method to gather this information would allow the use of history-related formulas in intraocular lens (IOL) power calculation after refractive surgery. SETTING: Second University of Naples, Naples, Italy. DESIGN: Case series. METHODS: The refractive effects, axial length (AL), and mean keratotomy (K) values were evaluated in eyes before and 6 months after photorefractive keratectomy for myopia or for myopic or mixed astigmatism. RESULTS: The study evaluated 257 eyes of 166 patients (93 women). Before surgery, there was a high correlation between refractive error and the product of AL and K (AL x K) (r(2) = 0.8213). In patients with refractive results close to emmetropia, the mean AL x K was 1005.91 +/- 25.88 (SD), meaning that in the range of 954 and 1058, there was a 95% possibility that the patients were almost fully corrected. The following regression formula was obtained to calculate the amount of refractive error independent of cataract onset: Refractive error = -0.0157 x (AL x K) + 16.437. CONCLUSIONS: The regression formula determined whether the refraction depended on the onset of cataract and estimated the amount of undercorrection or overcorrection that occurred after refractive surgery, leading to improved estimation of the power of the IOL to be implanted. It may allow the use of history-related formulas in IOL power calculation for eyes that have had corneal refractive surgery.
引用
收藏
页码:2123 / 2128
页数:6
相关论文
共 50 条
  • [11] Updated practical intraocular lens power calculation after refractive surgery
    Jonna, Gowtham
    Channa, Prabjot
    CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (04) : 275 - 280
  • [12] Intraocular lens power calculation after previous laser refractive surgery
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04): : 759 - 765
  • [13] A new centralperipheral corneal curvature method for intraocular lens power calculation after excimer laser refractive surgery
    Saiki, Megumi
    Negishi, Kazuno
    Kato, Naoko
    Arai, Hiroyuki
    Toda, Ikuko
    Torii, Hidemasa
    Dogru, Murat
    Tsubota, Kazuo
    ACTA OPHTHALMOLOGICA, 2013, 91 (02) : e133 - e139
  • [14] Intraocular lens power calculation after corneal refractive surgery: Double-K method
    Aramberri, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11): : 2063 - 2068
  • [15] Intraocular lens power calculation after corneal refractive surgery remains challenging
    Sun, R
    Gimbel, H
    Penno, EEA
    OPHTHALMOLOGY, 2000, 107 (02) : 226 - 227
  • [16] Accuracy of Formulas for Intraocular Lens Power Calculation After Myopic Refractive Surgery
    Lanza, Michele
    Ruggiero, Adriano
    Ha, Jason
    Simonelli, Francesca
    Kane, Jack X.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (07) : 443 - 449
  • [17] Intraocular lens power calculation following laser refractive surgery
    Hodge, Christopher
    McAlinden, Colm
    Lawless, Michael
    Chan, Colin
    Sutton, Gerard
    Martin, Aifric
    EYE AND VISION, 2015, 2
  • [18] Intraocular lens power calculation following laser refractive surgery
    Christopher Hodge
    Colm McAlinden
    Michael Lawless
    Colin Chan
    Gerard Sutton
    Aifric Martin
    Eye and Vision, 2
  • [19] Measuring corneal power for intraocular lens power calculation after refractive surgery - Comparison of methods
    Kim, JH
    Lee, DH
    Joo, CK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (11): : 1932 - 1938
  • [20] Prediction accuracy of intraocular lens power calculation methods after laser refractive surgery
    Yubo Wu
    Songyu Liu
    Rongfeng Liao
    BMC Ophthalmology, 17