The origin of sample memory in the Chalk River accelerator mass spectrometry sputter ion source

被引:3
|
作者
Koslowsky, VT
Andrews, HR
Davies, WG
Forster, JS
Imahori, Y
机构
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1996年 / 67卷 / 03期
关键词
D O I
10.1063/1.1146683
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The origin of memory effects in the Chalk River accelerator mass spectrometry sputter ion source has been studied by tracer and elastic-recoil-detection surface analysis techniques. For Cl-36 measurements, the results indicate that the memory arises from contamination of the region immediately surrounding the sample and that it can be mitigated by operating this portion of the ion source above 350 degrees C. This has reduced memory effects by a factor of 10 or more and has resulted in a similar improvement in background. (C) 1996 American Institute of Physics.
引用
收藏
页码:1416 / 1418
页数:3
相关论文
共 50 条
  • [1] Reduction of sample memory effects in the Chalk River AMS ion source
    Chalk River Lab, Chalk River, Canada
    Nucl Instrum Methods Phys Res Sect B, 1-4 (226-229):
  • [2] The reduction of sample memory effects in the Chalk River AMS ion source
    Koslowsky, VT
    Andrews, HR
    Davies, WG
    Imahori, Y
    Bolusmjak, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 123 (1-4): : 226 - 229
  • [3] ACCELERATOR MASS-SPECTROMETRY AT CHALK-RIVER
    ANDREWS, HR
    BALL, GC
    BROWN, RM
    BURN, N
    DAVIES, WG
    IMAHORI, Y
    MILTON, JCD
    WORKMAN, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 5 (02): : 134 - 138
  • [4] A NEW CS SPUTTER ION-SOURCE FOR ACCELERATOR MASS-SPECTROMETRY
    HOPFL, R
    BRETSCHNEIDER, T
    BUCHLER, A
    CHARASSE, Y
    ERNST, W
    FINCKH, E
    GOBLIRSCH, R
    GUMBMANN, F
    HALLER, M
    KARSCHNICK, R
    KRETSCHMER, W
    RAUSCHER, A
    SCHIELEIN, H
    SCHLEICHER, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (04): : 2469 - 2471
  • [5] A NEW DESIGN OF A CS SPUTTER ION-SOURCE FOR ACCELERATOR MASS-SPECTROMETRY
    NIKLAUS, TR
    BAUR, W
    BONANI, G
    SYNAL, HA
    WOLFLI, W
    SUTER, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (04): : 2485 - 2487
  • [6] Sputter Negative Ion Source at BINP Accelerator Mass Spectrometer
    Konstantinov, E.
    Goncharov, A.
    Konstantinov, S.
    Petrozhitsky, A.
    Parkhomchuk, V.
    Rastigeev, S.
    SIXTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2018), 2018, 2052
  • [7] A microbeam Cs ion source for accelerator mass spectrometry
    Sie, SH
    Niklaus, TR
    Suter, GF
    Bruhn, F
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (03): : 1353 - 1358
  • [8] The new Chalk River AMS ion source, sample changer and external sample magazine
    Koslowsky, VT
    Bray, N
    Imahori, Y
    Andrews, HR
    Davies, WG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 123 (1-4): : 203 - 207
  • [9] Coupling of a He-jet transfer system to a Cs sputter ion source for the acceleration of radioactive ions with the Chalk River MP Tandem accelerator
    Koslowsky, VT
    Andrews, HR
    Beeching, D
    Bray, N
    Davies, WG
    Hagberg, E
    Hardy, JC
    Imahori, Y
    Watson, MJ
    Savard, G
    Ellis, M
    Bolusmjak, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 126 (1-4): : 190 - 193
  • [10] Coupling of a He-jet transfer system to a Cs sputter ion source for the acceleration of radioactive ions with the Chalk River MP tandem accelerator
    Koslowsky, V.T.
    Andrews, H.R.
    Beeching, D.
    Bray, N.
    Davies, W.G.
    Hagberg, E.
    Hardy, J.C.
    Imahori, Y.
    Watson, M.J.
    Savard, G.
    Ellis, M.
    Bolusmjak, M.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1997, 126 (1-4): : 190 - 193