Data-driven Improved Sampling in PET

被引:0
|
作者
Galve, P. [1 ]
Lopez-Montes, A. [1 ]
Udias, J. M. [1 ]
Moore, S. C. [2 ,3 ]
Herraiz, J. L. [1 ]
机构
[1] Univ Complutense Madrid, Fac Ciencias Fis, Grp Fis Nucl & Uparcos, CEI Moncloa, Madrid 28040, Spain
[2] Brigham & Womens Hosp, Div Nucl Med, 75 Francis St, Boston, MA 02115 USA
[3] Harvard Med Sch, Boston, MA USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Positron Emission Tomography (PET) scanners are usually designed with the goal to obtain the best compromise between sensitivity, resolution, field-of-view size, and cost. Therefore, it is difficult to improve the resolution of a PET scanner with hardware modifications, without affecting some of the other important parameters. Iterative image reconstruction methods such as the ordered subsets expectation maximization (OSEM) algorithm are able to obtain some resolution recovery by using a realistic system response matrix that includes all the relevant physical effects. Nevertheless, this resolution recovery is often limited by reduced sampling in the projection space, determined by the geometry of the detector. The goal of this work is to improve the resolution beyond the detector size limit by increasing the sampling with data-driven interpolated data. A maximum-likelihood estimation of the counts in each virtual sub-line-of-response (subLOR) is obtained after a complete image reconstruction, conserving the statistics of the initial data set. The new estimation is used for the next complete reconstruction. The method typically requires two or three of these full reconstructions (superiterations). We have evaluated it with simulations and real acquisitions for the Argus and Super Argus preclinical PET scanners manufactured by SMI, considering different types of increased sampling. Quantitative measurements of recovery and resolution evolution against noise per iteration for the standard OSEM and successive superiterations show promising results. The procedure is able to reduce significantly the impact of depth-of-interaction in large crystals, and to improve the spatial resolution. The proposed method is quite general and it can be applied to other scanners and configurations.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Decomposition and Adaptive Sampling for Data-Driven Inverse Linear Optimization
    Gupta, Rishabh
    Zhang, Qi
    INFORMS JOURNAL ON COMPUTING, 2022, 34 (05) : 2720 - 2735
  • [32] A data-driven approach to sampling matrix selection for compressive sensing
    Farnell, Elin
    Kvinge, Henry
    Dixon, John P.
    Dupuis, Julia R.
    Kirby, Michael J.
    Peterson, Chris
    Schundler, Elizabeth C.
    Smith, Christian W.
    COMPUTATIONAL IMAGING V, 2020, 11396
  • [33] A Data-Driven Adaptive Sampling Method Based on Edge Computing
    Lou, Ping
    Shi, Liang
    Zhang, Xiaomei
    Xiao, Zheng
    Yan, Junwei
    SENSORS, 2020, 20 (08)
  • [34] Accelerating Liquid Simulation With an Improved Data-Driven Method
    Gao, Yang
    Zhang, Quancheng
    Li, Shuai
    Hao, Aimin
    Qin, Hong
    COMPUTER GRAPHICS FORUM, 2020, 39 (06) : 180 - 191
  • [35] Managing Uncertainty Information for Improved Data-Driven Modelling
    Rendall, Ricardo
    Reis, Marco S.
    Chin, Swee-Teng
    Chiang, Leo
    26TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING (ESCAPE), PT B, 2016, 38B : 1575 - 1580
  • [36] Data-driven method for an improved linearised AVO inversion
    Niu, Liping
    Geng, Jianhua
    Wu, Xinming
    Zhao, Luanxiao
    Zhang, Hong
    JOURNAL OF GEOPHYSICS AND ENGINEERING, 2021, 18 (01) : 1 - 22
  • [37] Data-driven optimal binning for respiratory motion management in PET
    Kesner, Adam L.
    Meier, Joseph G.
    Burckhardt, Darrell D.
    Schwartz, Jazmin
    Lynch, David A.
    MEDICAL PHYSICS, 2018, 45 (01) : 277 - 286
  • [38] Dual Respiratory and Cardiac Data-driven Gating in PET Imaging
    Qi, Wenyuan
    Yang, Li
    Tsai, Yu-Jung
    Qi, Jinyi
    Asma, Evren
    Kolthammer, Jeffrey
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [39] Clinical Evaluation of Data-driven Motion Correction for PET Imaging
    Uribe, C. F.
    Rousseau, E.
    Lacroix-Poisson, F.
    Alden, T.
    Wollenweber, S.
    Benard, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S360 - S361
  • [40] Real-time data-driven motion correction in PET
    Adam Kesner
    C. Ross Schmidtlein
    Claudia Kuntner
    EJNMMI Physics, 6