Dual-rotator mueller matrix polarimeter for high-accuracy and high-precision measurements of glucose concentration

被引:3
|
作者
Cai, Zhi-Yu [1 ]
Lo, Yu-Lung [1 ]
Chang, Ching-Min [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Mech Engn, Tainan 701401, Taiwan
来源
OPTIK | 2021年 / 245卷
关键词
Mueller matrix polarimeter; Dual-rotator design; Error analysis; Synchronization;
D O I
10.1016/j.ijleo.2021.167662
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A Mueller matrix polarimeter incorporating two rotating retarders is proposed for determining the glucose concentration in aqueous solutions. In the proposed system, the accuracy and precision of the Mueller matrix measurements are enhanced through an effective compensation of both the systematic errors in the polarimeter and the environmental errors. Moreover, the synchronization of the two retarders is effectively controlled through the use of a simple discontinuous rotation strategy. The validity of the proposed compensation method is demonstrated numerically and experimentally using an air sample for illustration purposes. It is shown that the maximum error and maximum standard deviation of the measured Mueller matrix elements are +/- 0.0102 and +/- 0.0008, respectively. In addition, the response time is just 1 min. In experimental trials performed in the transmission mode using aqueous glucose samples, the maximum standard deviation of the optical rotation angle is found to be just 0.0388 degrees with a path length of 40 mm. Moreover, the extracted rotation angle varies linearly (R-2 = 0.9176) with the glucose concentration over the concentration range of 100-500 mg/dL. Hence, the feasibility of the calibrated Mueller matrix polarimeter for glucose determination applications is confirmed.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] A high-accuracy measurement method of glucose concentration in interstitial fluid based on microdialysis
    Li, Dachao
    Xu, Qingmei
    Liu, Yu
    Wang, Ridong
    Xu, Kexin
    Yu, Haixia
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (11)
  • [22] High-accuracy, high-resolution downwash flow field measurements of an unmanned helicopter for precision agriculture
    Tang, Qing
    Zhang, Ruirui
    Chen, Liping
    Xu, Gang
    Deng, Wei
    Ding, Chenchen
    Xu, Min
    Yi, Tongchuan
    Wen, Yao
    Li, Longlong
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2020, 173
  • [23] High-accuracy multi-step eigenvalue calibration method for Mueller matrix polarization imaging system
    Li, Jianhui
    Li, Yanqiu
    Zhou, Guodong
    Wang, Jiazhi
    Zheng, Meng
    Liu, Ke
    Liu, Lihui
    AOPC 2020: OPTICAL SENSING AND IMAGING TECHNOLOGY, 2020, 11567
  • [24] High-accuracy temperature measurements call for PRTDs and precision delta-sigma ADCs
    Mirza, Sohail
    Shtargot, Joseph
    EDN, 2011, 56 (16) : 41 - 46
  • [25] HIGH-PRECISION SIMS MEASUREMENTS OF DOPANT CONCENTRATION IN III-V-SEMICONDUCTORS
    MILLER, JN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 218 (1-3): : 547 - 550
  • [26] Features of Capacitive Displacement Sensing That Provide High-Accuracy Measurements with Reduced Manufacturing Precision
    Peng, Kai
    Yu, Zhicheng
    Liu, Xiaokang
    Chen, Ziran
    Pu, Hongji
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (09) : 7377 - 7386
  • [27] Isotope dilution with matrix element removal:: A key for high-precision, high-accuracy trace analysis of geological samples using inductively coupled plasma-mass spectrometry
    Pin, C
    Le Fèvre, B
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2002, 26 (02): : 135 - 148
  • [28] Volumetric, electric, and magnetic properties of thioxanthen-9-one in aprotic solvents as revealed by high-precision densitometry, high-accuracy refractometry and magnetic susceptibility measurements and by DFT calculations
    Alvarado, YJ
    Caldera-Luzardo, J
    De La Cruz, C
    Ferrer-Amado, G
    Michelena, E
    Silva, P
    JOURNAL OF SOLUTION CHEMISTRY, 2006, 35 (01) : 29 - 49
  • [29] Volumetric, Electric, and Magnetic Properties of Thioxanthen-9-one in Aprotic Solvents as Revealed by High-Precision Densitometry, High-Accuracy Refractometry and Magnetic Susceptibility Measurements and by DFT Calculations
    Ysaías J. Alvarado
    José Caldera-Luzardo
    Carlos De La Cruz
    Gladys Ferrer-Amado
    Elba Michelena
    Pedro Silva
    Journal of Solution Chemistry, 2006, 35 : 29 - 49
  • [30] High-precision Temperature Measurement in the EtherCAT-Terminal-System Reproducible Measurements with certified Accuracy
    不详
    ATP EDITION, 2009, (09): : 52 - 52