Air Conditioning Heat Pump System Design of Xi'an Third Sewage Treatment Plant

被引:0
|
作者
Ju, Ji-Sheng [1 ]
Wu, Rong-Hua [1 ]
Yu, Hao [1 ]
机构
[1] Qingdao Univ, Dept Mech Engn, Qingdao, Shandong, Peoples R China
关键词
Sewage-source heat pump; Heat exchanger; Air processing methods; Machine room;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Our country is energetically advocate saving energy and reducing consumption, Application of sewage-source heat pump system than the electric heating boiler save more than two-thirds of electricity, Which save more than 1/2 of coal resources than the traditional coal-fired boiler. As a result of the sewage-source heat pump heat source temperature is relatively stable throughout the year, the refrigeration and heating coefficient is about 40% higher than the traditional air source heat pump. The operating cost is only 50% similar to 60% of ordinary central air conditioning[ 1-2]. The purpose of this article is the third sewage heat pump air conditioning system design for xi 'an to meet the requirements of cooling and heating. Design is from the most basic load calculation, selection of heat pump, water pump selection, the design of heat exchanger, the determination of air distribution, air treatment mode selection, selection of fan coil units at the end of the room design, water system design, drawing design. All the calculation of the selection according to the size of the heating and cooling construction drawings accurate calculation, and is optimized according to different situations.
引用
收藏
页码:534 / 539
页数:6
相关论文
共 50 条
  • [41] Experimental research on seawater source heat pump (SSHP) air-conditioning system
    Shi, Zhigang
    Hu, Songtao
    Wang, Gang
    Li, Angui
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 509 - +
  • [43] Study on Application of Ground-source Heat Pump Air Conditioning System in Hohhot
    He, Lingli
    Yang, Shufeng
    Bai, Yefei
    ADVANCED RESEARCH ON MATERIAL ENGINEERING, CHEMISTRY AND BIOINFORMATICS, PTS 1 AND 2 (MECB 2011), 2011, 282-283 : 379 - +
  • [44] Refrigerant control strategies for residential air-conditioning and heat-pump system
    Su, Shun-Yu
    Zhang, Chun-Zhi
    Chen, Jian
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL.): : 91 - 95
  • [45] Fuel-cell ejector heat pump integrated system for annual air conditioning
    Lazzarin, Renato
    Noro, Marco
    Zamboni, Lorenzo
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2006, 1 (01) : 79 - 91
  • [46] Performance evaluation of a variable frequency heat pump air conditioning system for electric bus
    Peng, Qinghong
    Du, Qungui
    International Journal of Fluid Machinery and Systems, 2015, 8 (01) : 13 - 22
  • [47] Saving energy in the heat-pump air conditioning system driven by gas engine
    Xu, Zhenjun
    Yang, Zhao
    ENERGY AND BUILDINGS, 2009, 41 (02) : 206 - 211
  • [49] Innovative heating - Air conditioning system with electric heat pump in residential and services sectors
    Zanolin, S
    ENERGY EFFICIENCY IN HOUSEHOLD APPLIANCES AND LIGHTING, 2001, : 168 - 176
  • [50] Refrigerant Control Strategies for Residential Air-Conditioning and Heat-Pump System
    SU ShunyuZHANG ChunzhiCHEN JianCollege of Urban ConstructionWuhan University of Science and TechnologyWuhanHubei China
    湖南大学学报(自然科学版), 2009, 36(S1) (自然科学版) : 91 - 95