Measurement of water absorption in human cornea with differential absorption optical coherence tomography

被引:0
|
作者
Pircher, M [1 ]
Götzinger, E [1 ]
Leitgeb, R [1 ]
Fercher, AF [1 ]
Hitzenberger, CK [1 ]
机构
[1] Univ Vienna, Dept Med Phys, Vienna, Austria
关键词
optical coherence tomography; differential absorption; cornea; water concentration;
D O I
10.1117/12.478967
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
OCT has emerged in recent years to a powerful technique to measure tissue properties. Recently, OCT has been enhanced by methods providing spectroscopic information. Since water is a major constituent of most tissues, the measurement of its concentration in tissue is important for tissue diagnostics. We present measurements of water absorption in human cornea in vitro with a differential absorption optical coherence tomography technique. This technique uses two OCT images recorded simultaneously with two different light sources, one centered within (1488nm) and one centered outside (1312nm) of a water absorption band. To study influences of scattering on. the absorption images and on the calculated differential absorption coefficient, the cornea was measured and imaged under three different conditions: At first, the cornea was imaged in a hydrated condition, immediately after removal from the aqueous nutrient solution. Then it was dehydrated and imaged a second time, finally it was rehydrated, however, the water was replaced by Deuterium oxide, which shows negligible absorption in the used wavelength region, but otherwise has similar optical properties as water. The cornea containing H2O is well distinguishable from the cornea containing D2O With our method. For quantitative determination of absorption, we performed a linear regression analysis of logarithmic backscattered intensity versus imaging depth in the cornea for each wavelength. The difference of the slopes corresponds to the difference in the absorption coefficient. If the difference in the water absorption cross section is known, the water concentration in tissue can be calculated. The results are in good agreement with those expected theoretically.
引用
收藏
页码:290 / 294
页数:5
相关论文
共 50 条
  • [31] DIFFERENTIAL OPTICAL-ABSORPTION SPECTROMETER FOR MEASUREMENT OF TROPOSPHERIC POLLUTANTS
    EVANGELISTI, F
    BARONCELLI, A
    BONASONI, P
    GIOVANELLI, G
    RAVEGNANI, F
    APPLIED OPTICS, 1995, 34 (15): : 2737 - 2744
  • [32] Three dimensional polarization sensitive optical coherence tomography of normal and pathologic human cornea
    Götzinger, E
    Pircher, M
    Sticker, M
    Dejaco-Ruhsmann, I
    Kaminski, S
    Findl, O
    Skorpik, C
    Fercher, AF
    Hitzenberger, CK
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES, 2003, 5140 : 120 - 124
  • [33] Light absorption of (oxy-)hemoglobin assessed by spectroscopic optical coherence tomography
    Faber, DJ
    Mik, EG
    Aalders, MCG
    van Leeuwen, TG
    OPTICS LETTERS, 2003, 28 (16) : 1436 - 1438
  • [34] Measurement of the refractive index of human teeth by optical coherence tomography
    Meng, Zhuo
    Yao, X. Steve
    Yao, Hui
    Liang, Yan
    Liu, Tiegen
    Li, Yanni
    Wang, Guanhua
    Lan, Shoufeng
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (03)
  • [35] Polarimetric analysis of the human cornea measured by polarization-sensitive optical coherence tomography
    Fanjul-Velez, Felix
    Pircher, Michael
    Baumann, Bernhard
    Goetzinger, Erich
    Hitzenberger, Christoph K.
    Arce-Diego, Jose Luis
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (05)
  • [36] Optical coherence tomography analysis of hydrofluoric acid decontamination of human cornea by mannitol solution
    Nose, Ricardo M.
    Daga, Fabio B.
    Nose, Walton
    Kasahara, Niro
    BURNS, 2017, 43 (02) : 424 - 428
  • [37] Optical coherence tomography analysis of hydrofluoric acid decontamination of human cornea by mannitol solution
    Nose, Ricardo
    Daga, Fabio
    Forseto, Adriana
    Victor, Gustavo
    Sousa, Sidney
    Nose, Walton
    Kasahara, Niro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [38] Automatic measurement of central cornea thickness of eye anterior segment optical coherence tomography image
    Sun, Y.-K. (syk@mail.tsinghua.edu.cn), 1600, Press of Shanghai Scientific and Technical Publishers (30):
  • [39] Spectral optical coherence tomography - A novel technique for cornea imaging
    Kaluzny, Bartlomiej J.
    Kaluzny, Jakub J.
    Szkulmowska, Anna
    Gorczynska, Iwona
    Szkulmowski, Maciej
    Bajraszewski, Tomasz
    Wojtkowski, Maciej
    Targowski, Piotr
    CORNEA, 2006, 25 (08) : 960 - 965
  • [40] Optical Coherence Tomography (OCT) in Laser Bonding of Incisions in the Cornea
    Porat, Yishai
    Gabay, Ilan
    Varssano, David
    Barequet, Irina
    Neudorfer, Meira
    Rosner, Mordechai
    Katzir, Abraham
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XV, 2015, 9317