Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: Feasibility and comparison with transesophageal echocardiography

被引:0
|
作者
Hijazi, ZM
Wang, Z
Cao, QL
Koenig, P
Waight, D
Lang, R
机构
[1] Univ Chicago, Childrens Hosp, Pediat Cardiol Sect, Chicago, IL 60637 USA
[2] Univ Chicago Hosp, Dept Med, Cardiol Sect, Chicago, IL 60637 USA
关键词
intracardiac echocardiography; device closure; transcatheter closure;
D O I
10.1002/1522-726X(200102)52:2<194::AID-CCD1046>3.0.CO;2-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transesophageal echocardiography (TEE) has been employed successfully for guiding transcatheter device closure of secundum atrial septal defect (ASD) and patent foramen ovate (PFO). However, the use of TEE for device closure requires general anesthesia. Intracardiac echocardiography (ICE) can provide similar anatomical views that might replace the use of TEE for device closure. Eleven patients (eight female/three male) with secundum ASD and PFO associated with strokes underwent attempts at transcatheter closure of their defects under sequential TEE and ICE guidance (six patients) and under ICE alone (five patients). The ages of the patients ranged from 6.6 to 74.7 yr, and their weights ranged from 23 to 124.5 kg. The sizes of the defects, as measured by TEE (six patients), ranged from 3 to 27 mm and, as measured by ICE (11 patients), from 3 to 27 mm. The balloon-stretched diameter of the ASD, as measured by TEE (six patients), ranged from 16 to 38 mm and, as measured by ICE (11 patients), from 16 to 35 mm. Both techniques correlated well for the measured two-dimensional diameter and for the balloon-stretched diameter (r = 0.97 and 0.98, respectively). Both TEE and ICE provided similar views of the defects and the various stages of device deployment. Owing to the proximity of the left atrium to the esophagus, however, the images obtained by ICE were more helpful and informative than those obtained by TEE. All patients experienced successful device placement (six patients under both TEE and ICE; five patients under ICE guidance alone); complete closure of the defects was effected in nine patients, whereas two patients had small residual shunts. There were no complications. We conclude that ICE provides unique images of the atrial communications and measurements similar to those obtained by TEE. ICE potentially could replace TEE as a guiding imaging tool for ASD and PFO device closure, thus eliminating the need for general anesthesia. Cathet Cardiovasc Intervent 2001;52:194-199. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 50 条
  • [41] Percutaneous Atrial Septal Defect Or Patent Foramen Ovale Closure Guided By Intracardiac Ultrasound Comparison With Transesophageal Ultrasound Findings Before The Procedure
    Vavuranakis, Manolis
    Kavouras, Charalambos
    Vlaseros, Ioannis
    Vaina, Sophia
    Papaioannou, Theodoros
    Sanidas, Elias
    Stefanadis, Christodoulos
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 28D - 28D
  • [42] Intracardiac echocardiographr during percutaneous closure of atrial septal defect and patent foramen ovale
    Brochet, E
    Habib, G
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2005, 98 : 25 - 28
  • [43] Intracardiac Echocardiogram: Feasibility, Efficacy, and Safety for Guidance of Transcatheter Multiple Atrial Septal Defects Closure
    Seol, Jae-hee
    Kim, Ah-young
    Jung, Se-yong
    Choi, Jae-young
    Park, Yeon-jae
    Jung, Jo-won
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (09)
  • [44] Pitfalls in Echocardiographic Diagnosis of Patent Foramen Ovale by Transesophageal Echocardiography
    Naqvi, Tasneem Z.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (03) : 348 - 348
  • [45] Echocardiographic Assessment of Percutaneous Patent Foramen Ovale and Atrial Septal Defect Closure Complications
    Yared, Kibar
    Baggish, Aaron L.
    Solis, Jorge
    Durst, Ronen
    Passeri, Jonathan J.
    Palacios, Igor F.
    Picard, Michael H.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2009, 2 (02) : 141 - 149
  • [46] Eight-French Intracardiac Echocardiography - Safe and Effective Guidance for Transcatheter Closure in Atrial Septal Defects
    Kim, Nam Kyun
    Park, Su-Jin
    Shin, Jae Il
    Choi, Jae Young
    CIRCULATION JOURNAL, 2012, 76 (09) : 2119 - 2123
  • [47] Transcatheter closure of atrial septal defect and patent foramen ovale with ''Sideris buttoned device''
    Hellmuller, B
    Kaufmann, U
    Aeschbacher, B
    Fluri, M
    Meier, B
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1996, 126 (26) : 1143 - 1150
  • [48] Recent development of transcatheter closure of atrial septal defect and patent foramen ovale with occluders
    Tang, Baiyu
    Su, Feng
    Sun, Xiangke
    Wu, Qin
    Xing, Quansheng
    Li, Suming
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (01) : 433 - 443
  • [49] Cardiac magnetic resonance imaging and transesophageal echocardiography in patients with transcatheter closure of patent foramen ovale
    Nusser, T.
    Hoeher, M.
    Merkle, N.
    Grebe, O. C.
    Spiess, J.
    Kochs, M.
    Hombach, V.
    Woehrle, J.
    EUROPEAN HEART JOURNAL, 2006, 27 : 418 - 418
  • [50] Transcatheter patent foramen ovale closure is efficacious in patients with coexisting atrial septal aneurysm
    Jesurum, JT
    Gray, WA
    Spencer, MP
    Diehl, L
    Krabill, KA
    Olsen, JV
    Smith, C
    Reisman, M
    STROKE, 2004, 35 (01) : 257 - 257