Nonproportional scintillation response of NaI:Tl to low energy x-ray photons and electrons

被引:46
|
作者
Khodyuk, I. V. [1 ,2 ]
Rodnyi, P. A. [2 ]
Dorenbos, P. [1 ]
机构
[1] Delft Univ Technol, Fac Sci Appl, NL-2629 JB Delft, Netherlands
[2] St Petersburg State Polytech Univ, St Petersburg 195251, Russia
关键词
solid scintillation detectors; X-ray detection; NON-PROPORTIONALITY; LIGHT YIELD; INORGANIC SCINTILLATORS; RESOLUTION; NAI(TL); CRYSTALS;
D O I
10.1063/1.3431009
中图分类号
O59 [应用物理学];
学科分类号
摘要
Nonproportional response of the scintillation yield of NaI:Tl was measured using highly monochromatic synchrotron irradiation ranging from 9-100 keV. Special attention is paid to the x-ray escape peaks. They provide us additional information about photon response in the range 0.9-12 keV. A rapid variation in the photon response curve is observed near the iodine K-electron binding energy. A dense sampling of data is performed around this energy and that data are used to apply a method, which we call K-dip spectroscopy. This method allows us to derive the electron response curve of NaI:Tl down to energies as low as 30 eV. A comparison of our data with data of others employing different methods is made. Advantages, limitations, and peculiarities of presented techniques and methods are discussed. (C) 2010 American Institute of Physics. [doi:10.1063/1.3431009]
引用
收藏
页数:8
相关论文
共 50 条
  • [1] FABRICATION OF THIN NAI(TL) SCINTILLATION LAYERS FOR LOW ENERGY X-RAY DETECTION
    BAUER, RW
    WEINGART, RC
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1967, 55 (01): : 55 - &
  • [2] INVESTIGATION OF THE RESPONSE OF NAI(TL) SCINTILLATION DETECTORS USING AN X-RAY MONOCHROMATOR
    SHERBINI, SS
    SHAHABI, I
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1979, 164 (03): : 457 - 461
  • [3] SCINTILLATION EFFICIENCY OF A NAI(TL) CRYSTAL FOR LOW-ENERGY ELECTRONS
    TOJO, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 241 (01): : 177 - 180
  • [4] Calibration of NaI (Tl) Scintillation Survey Meter Using Industrial X-ray Equipment
    Suzuki, Katsunao
    Negishi, Toru
    Kato, Yoh
    Kono, Yasuhisa
    Sekimoto, Michiharu
    [J]. SENSORS AND MATERIALS, 2023, 35 (08) : 2961 - 2970
  • [5] SCINTILLATION SPECTROMETERS FOR MEASURING THE TOTAL ENERGY OF X-RAY PHOTONS
    FOOTE, RS
    KOCH, HW
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1954, 25 (08): : 746 - 758
  • [6] SCINTILLATION COUNTING OF LOW-ENERGY PHOTONS AND ITS USE IN X-RAY DIFFRACTION
    BRENTANO, JCM
    LADANY, I
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1954, 25 (10): : 1028 - 1029
  • [7] SCINTILLATION SPECTROMETER FOR MEASURING TOTAL ENERGY OF X-RAY PHOTONS
    CLELAND, MR
    KOCH, HW
    [J]. PHYSICAL REVIEW, 1952, 86 (04): : 588 - 588
  • [8] Response of NaI(Tl) to X-rays and electrons
    Wayne, LR
    Heindl, WA
    Hink, PL
    Rothschild, RE
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 411 (2-3): : 351 - 364
  • [9] X-RAY LUMINESCENCE OF NAI(TL) PHOSPHOR
    SHAMOVSKII, LM
    DUNINA, AA
    [J]. OPTICS AND SPECTROSCOPY-USSR, 1965, 18 (04): : 411 - +
  • [10] NONLINEAR RESPONSE OF NAI(TL) TO PHOTONS
    ENGELKEMEIR, D
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1956, 27 (08): : 589 - 591