Evaluation of a variable dose acquisition methodology for breast tomosynthesis - art. no. 691319

被引:4
|
作者
Das, Mini [1 ]
Gifford, Howard [1 ]
O'Connor, Michael [1 ]
Glick, Stephen [1 ]
机构
[1] Univ Massachusetts, Dept Radiol, Worcester, MA 01606 USA
关键词
tomosythesis; variable dose; micro-calcifications; LROC;
D O I
10.1117/12.773106
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study is to evaluate the recently proposed variable dose (VD) acquisition scheme that has been hypothesized to overcome the limitations of microcalcification detection in breast tomosynthesis. In this acquisition methodology, approximately half of the total dose is used for one central projection. This central projection view is similar to a conventional mammograrn and used to detect microcalcifications. The other half of the total dose is split among the rest of the projection views. These variable dose projection data are then reconstructed and the 3D slices are used for detection of masses. This novel acquisition methodology can potentially overcome the current limitations with microcalcification detection in breast tomosynthesis (BT) and may result in faster and more accurate detection of both microcalcifications and masses. Having access to both a conventional mammogram (i.e., the central projection) and tomosynthesis slices would also act as a bridge for radiologists who are used to viewing single projection images. In the current study, a comparison of microcalcification detection accuracy obtained using VD and conventional BT was conducted. A realistic computer simulation was used to model the realistic noise and blur encountered in BT systems. The simulation used a compressed breast phantom, modeled using CT images of compressed mastectomy specimens. Localization receiver operating characteristic (LROC) analysis was performed for detecting microcalcifications of size ranging from 147 microns to 178 microns. The results suggested higher microcalcification detection and localization accuracy using the VD technique. The complete study will also consist of evaluating detection of masses for the two strategies.
引用
收藏
页码:91319 / 91319
页数:8
相关论文
共 50 条
  • [1] Evaluation of a variable dose acquisition technique for microcalcification and mass detection in digital breast tomosynthesis
    Das, Mini
    Gifford, Howard C.
    O'Connor, J. Michael
    Glick, Stephen J.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 1976 - 1984
  • [2] Optimizing breast-tomosynthesis acquisition parameters with scanning model observers - art. no. 69170S
    Gifford, H. C.
    Didier, C. S.
    Das, Mini
    Glick, S. J.
    [J]. MEDICAL IMAGING 2008: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2008, 6917 : S9170 - S9170
  • [3] Classification of breast masses and normal tissues in digital tomosynthesis mammography - art. no. 691508
    Wei, Jun
    Chan, Heang-Ping
    Zhang, Yiheng
    Sahiner, Berkman
    Zhou, Chuan
    Ge, Jun
    Wu, Yi-Ta
    Hadjiiski, Lubomir M.
    [J]. MEDICAL IMAGING 2008: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2008, 6915 : 91508 - 91508
  • [4] Optimal spectra for indirect detector breast tomosynthesis - art. no. 61421L
    Glick, Stephen J.
    Gong, Xing
    [J]. Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : L1421 - L1421
  • [5] Optimizing filtered backprojection reconstruction for a breast tomosynthesis prototype device - art. no. 61420F
    Mertelmeier, Thomas
    Orman, Jasmina
    Haerer, Wolfgang
    Dudam, Mithun K.
    [J]. Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : F1420 - F1420
  • [6] Evaluation of the state of the art in digital breast tomosynthesis
    Pacifici, Stefano
    [J]. IMAGEN DIAGNOSTICA, 2014, 5 (02): : 64 - 67
  • [7] PATIENT DOSE EVALUATION IN DIGITAL BREAST TOMOSYNTHESIS
    Kisielewicz, K.
    Rawojc, K.
    Dziubinska, A.
    Mazur, L.
    Kieltyka, B.
    Najberg-Pierzchala, D.
    Gadek, M.
    Luczynska, E.
    Wos, Z.
    Heinze, S.
    Dziecichowicz, A.
    [J]. ACTA PHYSICA POLONICA B, 2020, 51 (01): : 345 - 349
  • [8] Colony image acquisition and segmentation - art. no. 672246
    Wang, W. X.
    [J]. ADVANCED OPTICAL MANUFACTURING TECHNOLOGIES, PTS 1 AND 2, 2007, 6722 : 72246 - 72246
  • [9] Automated ship image acquisition - art. no. 696319
    Hammond, T. R.
    [J]. UNATTENDED GROUND, SEA, AND AIR SENSOR TECHNOLOGIES AND APPLICATIONS X, 2008, 6963 : 96319 - 96319
  • [10] Tomosynthesis reconstruction using the simultaneous algebraic reconstruction technique (SART) on breast phantom data - art. no. 614249
    Zhang, Yiheng
    Chan, Heang-Ping
    Sahiner, Berkman
    Wei, Jun
    Goodsitt, Mitchell M.
    Hadjiiski, Lubomir M.
    Ge, Jun
    Zhou, Chuan
    [J]. Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : 14249 - 14249