RP-HPLC analysis of phenolic compounds and flavonoids in beverages and plant extracts using a CoulArray detector

被引:102
|
作者
Jandera, P
Skeríková, V
Rehová, L
Hájek, T
Baldriánová, L
Skopová, G
Kellner, V
Horna, A
机构
[1] Univ Pardubice, Fac Chem Technol, Dept Analyt Chem, CZ-53210 Pardubice, Czech Republic
[2] Acad Sci Czech Republ, Inst Macromol Chem, CZ-16206 Prague, Czech Republic
[3] Res Inst Brewing & Malting Plc, CZ-12044 Prague, Czech Republic
[4] T Bata Univ, Fac Technol, Dept Food Engn & Chem, CZ-76212 Zlin, Czech Republic
关键词
phenolic compounds; flavonoids; natural antioxidants; coulometric detection; beer; wine; tea; yacon;
D O I
10.1002/jssc.200500003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Methods were developed for the analysis of natural antioxidants including phenolic compounds and flavonoids in beverages and plant extracts using gradient HPLC with multi-channel electrochemical coulometric detection. Suitability of various reversed-phase columns for this purpose was compared; pH and mobile phase gradients were optimized with respect to the separation selectivity and sensitivity of detection. Because of different target compounds in various sample types, the overlapping resolution maps and the normalized resolution product approaches described earlier were used to select optimum columns and gradients to suit the analysis of the individual sample types. The methods were applied to the analysis of phenolic compounds and flavonoids in beer, wine, tea, and yacon extracts. 32 phenolic compounds were identified and determined, including derivatives of benzoic and cinnamic acids, flavones, and a few related glycosides. Eight-channel CoulArray detection offers high selectivity and sensitivity with limits of detection in the low mu g L-1 range, at least an order of magnitude lower than single-channel coulometric detection using the Coulochem detector. No special sample pretreatment is necessary and, because of the compatibility of the CoulArray detector with gradient elution, phenolic antioxidants of different polarities can be determined in a single run. In addition to the retention times, the ratios of the areas of the pre-dominant and post-dominant peaks to the area of the dominant peak can be used for improved identification of natural antioxidants.
引用
收藏
页码:1005 / 1022
页数:18
相关论文
共 50 条
  • [41] Simultaneous estimation of phenolic acids in sea buckthorn (Hippophae rhamnoides) using RP-HPLC with DAD
    Arimboor, Ranjith
    Kumar, K. Sarin
    Arumughan, C.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (01) : 31 - 38
  • [42] Dereplication of terpenes and phenolic compounds from Inga edulis extracts using HPLC-SPE-TT, RP-HPLC-PDA and NMR spectroscopy
    Lima, Nerilson M.
    Andrade, Teresinha J. A. S.
    Silva, Dulce Helena S.
    NATURAL PRODUCT RESEARCH, 2022, 36 (01) : 488 - 492
  • [43] Simultaneous Determination of Three Phenolic Compounds in the Fruit of Toona sinensis(A.Juss.) Roem.by RP-HPLC
    LI Song-lin1
    2.The Key Laboratory for Information System of Mountainous Area and Protection of Ecological Environment of Guizhou Province
    Medicinal Plant, 2011, (05) : 37 - 39
  • [44] Optimization of levofloxacin analysis by RP-HPLC using multivariate calibration technique
    Arayne, M. Saeed
    Sultana, Najma
    Siddiqui, Farhan Armed
    PAKISTAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2007, 20 (02) : 100 - 106
  • [45] Characterisation of phenolic compounds in Algerian honeys by RP-HPLC coupled to electrospray time-of-flight mass spectrometry
    Ouchemoukh, Salim
    Amessis-Ouchemoukh, Nadia
    Gomez-Romero, Maria
    Aboud, Farid
    Giuseppe, Alonzo
    Fernandez-Gutierrez, Alberto
    Segura-Carretero, Antonio
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2017, 85 : 460 - 469
  • [46] Corona Charged Aerosol Detector in studying retention and β-cyclodextrin complex stability using RP-HPLC
    Dajic, Nevena
    Otasevic, Biljana
    Malenovic, Andelija
    Zecevic, Mira
    Holzgrabe, Ulrike
    Protic, Ana
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 193
  • [47] A SIMPLE METHOD FOR CONCENTRATING VOLATILE FLAVOR COMPOUNDS IN AQUEOUS SYSTEMS USING RP-HPLC
    AISHIMA, T
    OZAWA, Y
    CHROMATOGRAPHIA, 1989, 28 (7-8) : 405 - 411
  • [48] Analysis of Polysorbate 80 and its Related Compounds by RP-HPLC with ELSD and MS Detection
    Zhang, R.
    Wang, Y.
    Tan, L.
    Zhang, H. Y.
    Yang, M.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2012, 50 (07) : 598 - 607
  • [49] Elaboration and validation of methods for quantitative analysis of phenolic compounds and flavonoids in the extracts of higher fungi
    Protsenko, M. A.
    Kostina, N. E.
    RUSSIAN JOURNAL OF BIOORGANIC CHEMISTRY, 2016, 42 (07) : 756 - 763
  • [50] Elaboration and validation of methods for quantitative analysis of phenolic compounds and flavonoids in the extracts of higher fungi
    M. A. Protsenko
    N. E. Kostina
    Russian Journal of Bioorganic Chemistry, 2016, 42 : 756 - 763