At in-service inspections in German nuclear power plants radiographic testing (RT) methods had been applied at a larger scale after. cracks had been detected at the media. affected inner surface of austenitic welds. The defect indications which follow the heat affected zone are difficult to evaluate in radiographs due to their. low er contrast and the presence of undercut and large density differences which occur as a result of mismatches and excess penetration. For the interpretation of crack-like indications an evaluation procedure has been developed which applies digital image processing with a scanning system of sufficiant high spatial resolution (35 mu m pixel width) and a grey-scale resolution of 12 bit (4096 grey levels). The procedure evaluates the half width, the maximum contrast of the RT indication and its length above a defined contrast threshold. This threshold takes into account the optical density, the signal-to-noise ratio and the wall thickness. By comparison with results from metallography of weld specimens for a large number of radiographic crack indications (true and false calls) criteria for a quantitative indication evaluation were definded.
引用
收藏
页码:805 / 808
页数:4
相关论文
共 50 条
  • [31] A digital image processing technique for quantification of surface hot-shortness cracks
    Garza, LG
    Van Tyne, CJ
    JOURNAL OF TESTING AND EVALUATION, 2006, 34 (01) : 1 - 4
  • [32] IMAGE-PROCESSING FOR FILM RADIOGRAPHS
    ENGELBART, RW
    MATERIALS EVALUATION, 1986, 44 (11) : 1293 - 1293
  • [33] Digital image processing for detection of wooden foreign bodies in plain radiographs of chicken thighs
    Hoffmeister, MJW
    Reese, GJ
    TenEyck, CRP
    Smeeks, FC
    PROCEEDINGS OF THE 1996 FIFTEENTH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1996, : 153 - 156
  • [34] Image Processing Pipeline to Improve the Detection of Vertical Root Fractures in Digital Periapical Radiographs
    Soares, Lucas E.
    Lima, Kaique L.
    Silva, Lorena R.
    Yamamoto-Silva, Fernanda P.
    Vieira, Marcelo A. C.
    XXVI BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2018, VOL. 2, 2019, 70 (02): : 253 - 258
  • [35] The challenge of applying digital image processing software on intraoral radiographs for osteoporosis risk assessment
    Gullberg, Joanna
    Al-Okshi, Ayman
    Asan, Dalia Homar
    Zainea, Anita
    Sundh, Daniel
    Lorentzon, Mattias
    Lindh, Christina
    DENTOMAXILLOFACIAL RADIOLOGY, 2022, 51 (01)
  • [36] ROC ANALYSIS FOR POST-PROCESSING OF IMAGE DATA OF DIGITAL LUMINESCENCE RADIOGRAPHS OF THE THORAX
    MULLER, RD
    HIRCHE, H
    VOSS, M
    BUDDENBROCK, B
    JOHN, V
    GOCKE, P
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 162 (02): : 163 - 169
  • [37] Image processing of medical radiographs for single image display
    Freedman, M
    Artz, DS
    Mun, SK
    SIXTH INTERNATIONAL CONFERENCE ON IMAGE PROCESSING AND ITS APPLICATIONS, VOL 1, 1997, (443): : 12 - 16
  • [38] The effects of gray scale image processing on digital mammography interpretation performance
    Cole, EB
    Pisano, ED
    Zeng, DL
    Muller, K
    Aylward, SR
    Park, S
    Kuzmiak, C
    Koomen, M
    Pavic, D
    Walsh, R
    Baker, J
    Gimenez, EI
    Freimanis, R
    ACADEMIC RADIOLOGY, 2005, 12 (05) : 585 - 595
  • [39] INTERPRETATION OF INTERFEROMETRIC FRINGE PATTERNS USING DIGITAL IMAGE-PROCESSING
    OSTEN, W
    SAEDLER, J
    ROTTENKOLBER, H
    TECHNISCHES MESSEN, 1987, 54 (7-8): : 285 - 290
  • [40] Interpretation of Interferometric Fringe Patterns using Digital Image Processing.
    Osten, W.
    Saedler, J.
    Rottenkolber, H.
    TM. Technisches Messen, 1987, 54 (7-8) : 285 - 290