Recursive independent component analysis (ICA)-decomposition of ictal EEG to select the best ictal component for EEG source imaging

被引:15
|
作者
Habib, Mohammad Ashfak [1 ,2 ,3 ]
Ibrahim, Fatimah [1 ,2 ]
Mohktar, Mas S. [1 ,2 ]
Kamaruzzaman, Shahrul Bahyah [2 ,4 ]
Lim, Kheng Seang [2 ,4 ]
机构
[1] Univ Malaya, Fac Engn, Dept Biomed Engn, Kuala Lumpur 50603, Malaysia
[2] Univ Malaya, Fac Engn, Ctr Innovat Med Engn, Kuala Lumpur 50603, Malaysia
[3] Chittagong Univ Engn & Technol, Dept Comp Sci & Engn, Chittagong 4349, Bangladesh
[4] Univ Malaya, Fac Med, Dept Med, Kuala Lumpur 50603, Malaysia
关键词
Focal epilepsy; Epileptogenic zone; Ictal EEG; Source localization; Surgical; Independent component analysis; SOURCE LOCALIZATION; PRESURGICAL EVALUATION; EPILEPTIC DISCHARGES; LOBE EPILEPSY; SCALP; ARTIFACTS; DYNAMICS; DECOMPOSITION; REDUCTION; RHYTHMS;
D O I
10.1016/j.clinph.2019.11.058
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: This study aimed to present a new ictal component selection technique, named as recursive ICA-decomposition for ictal component selection (RIDICS), for potential application in epileptogenic zone localization. Methods: The proposed technique decomposes ictal EEG recursively, eliminates a few unwanted components in every recursive cycle, and finally selects the most significant ictal component. Back-projected EEG, regenerated from that component, was used for source estimation. Fifty sets of simulated EEGs and 24 seizures in 8 patients were analyzed. Dipole sources of simulated-EEGs were compared with a known dipole location whereas epileptogenic zones of the seizures were compared with their corresponding sites of successful surgery. The RIDICS technique was compared with a conventional technique. Results: The RIDICS technique estimated the dipole sources at an average distance of 12.86 mm from the original dipole location, shorter than the distances obtained using the conventional technique. Epileptogenic zones of the patients, determined by the RIDICS technique, were highly concordant with the sites of surgery with a concordance rate of 83.33%. Conclusions: Results show that the RIDICS technique can be a promising quantitative technique for ictal component selection. Significance: Properly selected ictal component gives good approximation of epileptogenic zone, which eventually leads to successful epilepsy surgery. (C) 2019 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:642 / 654
页数:13
相关论文
共 50 条
  • [21] EEG Source Imaging With Spatio-Temporal Tomographic Nonnegative Independent Component Analysis
    Valdes-Sosa, Pedro A.
    Vega-Hernandez, Mayrim
    Miguel Sanchez-Bornot, Jose
    Martinez-Montes, Eduardo
    Antonieta Bobes, Maria
    HUMAN BRAIN MAPPING, 2009, 30 (06) : 1898 - 1910
  • [22] Independent component analysis reveals dynamic ictal BOLD responses in EEG-fMRI data from focal epilepsy patients
    LeVan, Pierre
    Tyvaert, Louise
    Moeller, Friederike
    Gotman, Jean
    NEUROIMAGE, 2010, 49 (01) : 366 - 378
  • [23] Independent component analysis of EEG signals
    Sun, LS
    Liu, Y
    Beadle, PJ
    PROCEEDINGS OF 2005 IEEE INTERNATIONAL WORKSHOP ON VLSI DESIGN AND VIDEO TECHNOLOGY, 2005, : 219 - 222
  • [24] Real-Time Adaptive EEG Source Separation Using Online Recursive Independent Component Analysis
    Hsu, Sheng-Hsiou
    Mullen, Tim R.
    Jung, Tzyy-Ping
    Cauwenberghs, Gert
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2016, 24 (03) : 309 - 319
  • [25] Imaging human EEG dynamics using independent component analysis
    Onton, Julie
    Westerfield, Marissa
    Townsend, Jeanne
    Makeig, Scott
    NEUROSCIENCE AND BIOBEHAVIORAL REVIEWS, 2006, 30 (06): : 808 - 822
  • [26] Movement-related EEG decomposition using independent component analysis
    Ruckay, Lukas
    Stastny, Jakub
    Sovka, Pavel
    2006 INTERNATIONAL CONFERENCE ON APPLIED ELECTRONICS, 2006, : 149 - 152
  • [27] Automated ictal EEG source imaging: A retrospective, blinded clinical validation study
    Baroumand, Amir G.
    Arbune, Anca A.
    Strobbe, Gregor
    Keereman, Vincent
    Pinborg, Lars H.
    Fabricius, Martin
    Rubboli, Guido
    Madsen, Camilla Gobel
    Jespersen, Bo
    Brennum, Jannick
    Henriksen, Otto Molby
    van Mierlo, Pieter
    Beniczky, Sandor
    CLINICAL NEUROPHYSIOLOGY, 2022, 141 : 119 - 125
  • [28] Automated ictal EEG source imaging: a retrospective, blinded clinical validation study
    Baroumand, Amir Ghasemi
    Arbune, Anca
    Strobbe, Gregor
    Keereman, Vincent
    van Mierlo, Pieter
    Beniczky, Sandor
    EPILEPSIA, 2021, 62 : 126 - 127
  • [29] Significance of Independent Component Analysis (ICA) for Epileptic Seizure Detection Using EEG Signals
    Harpale, Varsha K.
    Bairagi, Vinayak K.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON DATA ENGINEERING AND COMMUNICATION TECHNOLOGY, ICDECT 2016, VOL 2, 2017, 469 : 829 - 838
  • [30] Online Recursive Independent Component Analysis for Real-time Source Separation of High-density EEG
    Hsu, Sheng-Hsiou
    Mullen, Tim
    Jung, Tzyy-Ping
    Cauwenberghs, Gert
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3845 - 3848