Reliability assessment of aged SiR insulators under humidity and pollution conditions

被引:28
|
作者
Ahmadi-veshki, Mohammad Reza [1 ]
Mirzaie, Mohammad [1 ]
Sobhani, Reza [1 ]
机构
[1] Babol Noshirvani Univ Technol, Fac Elect & Comp Engn, Babol Sar, Iran
关键词
SiR insulators; Accelerated aging test; Pollution; Reliability; Risk estimation; Flashover probability; AC FLASHOVER VOLTAGE; COMPOSITE INSULATORS; LEAKAGE CURRENT; FOG; PORCELAIN; PERFORMANCE; RESPECT; STRINGS;
D O I
10.1016/j.ijepes.2019.105679
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the effect of different pollution and humidity variations on the reliability of aged Silicone Rubber (SiR) insulators are investigated. Firstly, four different types of 20 kV SiR insulators have been selected to evaluate the effect of different insulator profiles on Flashover Voltage (FOV). Then artificially accelerated aging tests with 1000 h duration have been conducted for the aging of insulators. Numerous FOV tests have been carried out on the aged SiR insulators under different humidity and pollutions. Next, the risk of insulators utilization under different ambient conditions have been calculated by using the experimental test's data. Finally, the reliability of insulators under different conditions have been calculated and a new mathematical model for the reliability in different humidity has been proposed. The effect of SiR insulator profiles on FOV has been studied and the results have been shown that lower FOV is related to insulators with thicker profiles as well.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] LONG-TERM TESTS OF HVDC INSULATORS UNDER NATURAL POLLUTION CONDITIONS AT THE BIG EDDY TEST CENTER
    LAMPE, W
    HOGLUND, T
    NELLIS, C
    RENNER, P
    STEARNS, R
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (01) : 248 - 259
  • [42] Assessment of Reliability Indicators of Space Vehicles under Conditions of Incomplete Data
    Lomakin, M. I.
    Sukhov, A. V.
    Dokukin, A. V.
    Niyazova, Yu. M.
    COSMIC RESEARCH, 2021, 59 (03) : 199 - 203
  • [43] Risk assessment of desert pollution on composite high voltage insulators
    El-Shahat, Mohammed
    Anis, Hussein
    JOURNAL OF ADVANCED RESEARCH, 2014, 5 (05) : 569 - 576
  • [44] Performance of hv insulators under environmental pollution in aried area
    Hossam-Eldin, AA
    Ali, MM
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS - ICSD '98, 1998, : 414 - 417
  • [45] Study on DC Pollution Flashover Performance of Various Types of Long String Insulators Under Low Atmospheric Pressure Conditions
    Zhang, Zhijin
    Jiang, Xinliang
    Chao, Yafeng
    Chen, Ling
    Sun, Caixin
    Hu, Jianlin
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) : 2132 - 2142
  • [46] Electrical Performance of Composite Insulators under Icing Conditions
    Yin, F.
    Jiang, X.
    Farzaneh, M.
    Hu, J.
    Liu, Y.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 815 - 818
  • [47] Performance of nonceramic insulators under tropical field conditions
    Fernando, MARM
    Gubanski, SM
    IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (01) : 355 - 360
  • [48] Evaluation methods of polymer insulators under contaminated conditions
    Matsuoka, R. (matsuoka@isc.chubu.ac.jp), 1600, IEEE Power Engineering Society, IEEE Japan (Institute of Electrical and Electronics Engineers Inc.):
  • [49] Electrical Performance of Composite Insulators under Icing Conditions
    Yin, Fanghui
    Jiang, Xingliang
    Farzaneh, Masoud
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (06) : 2584 - 2593
  • [50] Evaluation methods of polymer insulators under contaminated conditions
    Matsuoka, R
    Naito, K
    Irie, T
    Kondo, K
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 2197 - 2202