Relationship of Vocal cord paralysis to the coil diameter of vagus nerve stimulator leads

被引:12
|
作者
Robinson, Leslie C. [1 ]
Winston, Ken R. [1 ,2 ,3 ,4 ]
机构
[1] Univ Colorado, Sch Med, Dept Neurosurg, Aurora, CO USA
[2] Denver Hlth & Hosp, Denver, CO USA
[3] Univ Hosp, Aurora, CO USA
[4] Childrens Hosp Colorado, Aurora, CO USA
关键词
complications; epilepsy; vocal cord paralysis; vagus nerve injury; vagus nerve stimulator lead; EPILEPSY; SEIZURES; COMPLICATIONS; CHILDREN; SAFETY; TRIAL;
D O I
10.3171/2014.10.JNS14640
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECT This investigation was done to examine, following implantation of vagus nerve stimulators, the relationship of vocal cord paralysis to the inner diameter of the coils used to attach the stimulator lead to the nerve. METHODS All data in this investigation were collected, as mandated by the FDA, by the manufacturer of vagus nerve stimulators and were made available without restrictions for analysis by the authors. The data reflect all initial device implantations in the United States for the period from 1997 through 2012. RESULTS Vocal cord paralysis was reported in 193 of 51,882 implantations. In patients aged 18 years and older, the incidence of paralysis was 0.26% when the stimulator leads had coil diameters of 3 mm and 0.51% when the leads had 2-mm-diameter coils (p < 0.05). Across all age groups, the incidence of vocal cord paralysis increased with age at implantation for leads having 2-mm-diameter coils. CONCLUSIONS In patients aged 18 years,and older, vocal cord paralysis occurred at almost twice the rate with the implantation of vagus nerve stimulator leads having 2-mm-diameter coils than with leads having 3-mm-diameter coils. The incidence of vocal cord paralysis increases with patient age at implantation.
引用
收藏
页码:532 / 535
页数:4
相关论文
共 50 条
  • [41] Factors of postoperative recurrent laryngeal nerve paralysis and recovery of vocal cord movement in thyroid surgery
    Obata, Kazufumi
    Kurose, Makoto
    Kakiuchi, Akito
    Takano, Kenichi
    AURIS NASUS LARYNX, 2024, 51 (05) : 892 - 897
  • [42] Idiopathic Vocal Cord Paralysis in the Radiated Neck: A Harbinger for Malignant Peripheral Nerve Sheath Tumour
    Dziegielewski, Peter T.
    O'Hara, Carolyn
    Erickson, Bree
    Seikaly, Hadi
    Harris, Jeffrey R.
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2012, 41 (04): : 246 - 252
  • [43] INTRAOPERATIVE NERVE MONITORING (IONM) IMPROVES SIGNIFICANTLY VOCAL CORD PARALYSIS RATES IN BENIGN THYROIDECTOMY
    Staubitz, J. I.
    Watzka, F.
    Poplawski, A.
    Riss, P.
    Clerici, T.
    Bergenfelz, A.
    Musholt, T. J.
    BRITISH JOURNAL OF SURGERY, 2020, 107 : 5 - 5
  • [44] Intraoperative Nerve Monitoring and Vocal Cord Paralysis: Have Rates Really Risen after the Adoption of Intraoperative Nerve Monitoring?
    Chau Nguyen
    Wang, Marilene
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2015, 220 (05) : 972 - 973
  • [45] Evaluation of feasibility of 1.5 Tesla prostate MRI using body coil RF transmit in a patient with an implanted vagus nerve stimulator
    Favazza, Christopher P.
    Edmonson, Heidi A.
    Ma, Chi
    Shu, Yunhong
    Felmlee, Joel P.
    Watson, Robert E.
    Gorny, Krzysztof R.
    MEDICAL PHYSICS, 2017, 44 (11) : 5749 - 5754
  • [46] Vocal Cord Paralysis after Percutaneous Embolization of a Vagal Paraganglioma-The Role of Intraoperative Nerve Monitoring
    Panja, Shantanu
    Kovoor, Jerry M.
    Shenoy, Ashok M.
    Chavan, Purushottam
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (11) : 1770 - 1772
  • [47] 3 Tesla MRI of Patients With a Vagus Nerve Stimulator: Initial Experience Using a T/R Head Coil Under Controlled Conditions
    Gorny, Krzysztof R.
    Bernstein, Matt A.
    Watson, Robert E., Jr.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (02) : 475 - 481
  • [48] Recurrent laryngeal nerve paralysis in a lung cancer patient: A cause of contralateral vocal cord hypermetabolism on PET/CT
    Gorospe, Luis
    Arrieta, Paola
    Lucia Santos-Carreno, Astrid
    Martinez San Milian, Juan
    Barrios-Barreto, Deisy
    MEDICINA CLINICA, 2017, 149 (12): : 563 - 563
  • [49] The incidence of recurrent laryngeal nerve injury resulting in vocal cord paralysis following interventional congenital catheterisation procedures
    Shahrier, Aniqa Z.
    Chinchilli, Vernon M.
    Qureshi, Athar M.
    Prieto, Lourdes R.
    Levi, Daniel S.
    Boe, Brian A.
    Turner, Daniel R.
    Rubio, Agustin E.
    Trucco, Sara M.
    Devanagondi, Rajiv
    Law, Mark A.
    Bass, John L.
    Pihkala, Jaana, I
    Weber, Howard S.
    CARDIOLOGY IN THE YOUNG, 2022, 32 (12) : 1952 - 1956
  • [50] A comparative analysis of laryngeal nerve damage in patients with idiopathic vocal cord paralysis exhibiting different paralytic sides
    Liu, Xiao-Hong
    Yan, Jing
    Li, Na
    Zhang, Qing-Qing
    Xie, Meng
    Guo, Rui-Xin
    Du, Xiao-Ying
    Chen, Yang-Juan
    Kong, De-Min
    Yang, Min-Juan
    Ren, Xiao-Yong
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2024, 9 (01):