Feasibility study of a dosimeter for in vivo measurements of the absolute dose delivered in high dose rate brachytherapy

被引:2
|
作者
Carrara, M. [1 ]
Gambarini, G. [2 ,3 ]
Borroni, M. [1 ]
Tomatis, S. [1 ]
Cerrotta, A. [4 ]
Fallai, C. [4 ]
Olmi, P. [4 ]
Zonca, G. [1 ]
机构
[1] Fdn IRCCS Ist Nazl Tumori, Med Phys Unit, I-20133 Milan, Italy
[2] Univ Milan, Dipartimento Fis, I-20133 Milan, Italy
[3] Ist Nazl Fis Nucl, Sez Milano, I-20133 Milan, Italy
[4] Fdn IRCCS Ist Nazl Tumori, Radiotherapy Unit, I-20133 Milan, Italy
关键词
GEL-LAYER DOSIMETRY; PERSPECTIVES;
D O I
10.1393/ncb/i2010-10878-2
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Radiation doses delivered to the patient during high dose rate brachytherapy treatments are susceptible to many inaccuracies and may not accurately match the planned doses. In vivo dosimetry is a reliable solution to compare planned and delivered dose distributions, representing therefore a valid tool to increment treatment accuracy. In this study, dosimetric catheters were developed in laboratory and optimized to be used for in vivo measurements of high close rate brachytherapy treatments. Measurements were performed in different irradiation configurations with ad hoc developed phantoms. Preliminary measurements of dose distributions achieved with a 6MV linear accelerator showed a high linear response of the dosimetric catheters with the delivered dose. Moreover, measurements performed with the brachytherapy high dose rate remote afterloading device provided with an Ir-192 radioactive source showed high accordance between planned dose and dose measured with the dosimetric catheters at 1 mm 3 spatial resolution. Results show that dosimetric catheters are valid candidates for performing in-vivo linear dosimetry in HDR brachytherapy, representing an innovative tool that could help to significantly increase safety and accuracy in the brachytherapy treatments delivery. Eventually, these improvements might conduce to the best achievable therapeutic results, that is higher survival and recovery rates of the patients.
引用
收藏
页码:667 / 673
页数:7
相关论文
共 50 条
  • [1] A Novel Continuous Dosimeter for In-Vivo Absolute Dose Measurements in High Dose Rate Brachytherapy
    Carrara, M.
    Gambarini, G.
    Gambini, I.
    Tomatis, S.
    Fallai, C.
    Olmi, P.
    Zonca, G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S577 - S578
  • [2] A plastic scintillation dosimeter for high dose rate brachytherapy
    Lambert, J.
    McKenzie, D. R.
    Law, S.
    Elsey, J.
    Suchowerska, N.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (21): : 5505 - 5516
  • [3] A plastic scintillation dosimeter for high dose rate brachytherapy
    Lambert, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S32 - S32
  • [4] SCINTILLATING FIBER DOSIMETER FOR IN VIVO DOSE MEASUREMENTS IN HDR BRACHYTHERAPY.
    Therriault-Proulx, F.
    Villeneuve, M.
    Martin, A. G.
    Gingras, L.
    Beddar, S.
    Beaulieu, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 91 : S14 - S14
  • [5] IN VIVO TLD DOSE MEASUREMENTS IN CATHETER-BASED HIGH-DOSE-RATE BRACHYTHERAPY
    Adliene, Diana
    Jakstas, Karolis
    Urbonavicius, Benas Gabrielis
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 477 - 481
  • [6] Sigmoid dose delivered by high-dose-rate brachytherapy versus low-dose-rate brachytherapy for cervical cancer
    Holloway, C. L.
    O'Farrell, D. A.
    Cormack, R. A.
    Viswanathan, A. N.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S165 - S165
  • [7] "In vivo" Dose Measurements in High-Dose-Rate Brachytherapy Treatments for Cervical Cancer: A Project Proposal
    Reynoso Mejia, C. A.
    Buenfil Burgosa, A. E.
    Ruiz Trejo, C.
    Mota Garcia, A.
    Trejo Duran, E.
    Rodriguez Ponce, M.
    Gamboa de Buen, I.
    [J]. ELEVENTH MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2010, 1310 : 134 - +
  • [8] In vivo measurements for high dose rate brachytherapy with optically stimulated luminescent dosimeters
    Sharma, Renu
    Jursinic, Paul A.
    [J]. MEDICAL PHYSICS, 2013, 40 (07)
  • [9] HIGH DOSE RATE BRACHYTHERAPY: IN VIVO DOSIMETRY OF RADIATION DOSE TO THE RECTUM
    Ullen, A.
    Gorzov, P.
    Nilsson, J.
    Holmberg, C.
    Lundell, M.
    Kalkner, K. M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S379 - S379
  • [10] Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy
    Rosales, Haydee M. Linares
    Duguay-Drouin, Patricia
    Archambault, Louis
    Beddar, Sam
    Beaulieu, Luc
    [J]. MEDICAL PHYSICS, 2019, 46 (05) : 2412 - 2421