A flow-injection continuous filtration approach for the automatic determination of monoclonal antibodies

被引:2
|
作者
FernandezRomero, JM [1 ]
deCastro, MDL [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
flow injection; continuous filtration; heterogeneous immunoassay; fluorimetry; immunoglobulin;
D O I
10.1016/0003-2670(96)00232-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An unsegmented continuous manifold for development of a heterogeneous immunoassay has been developed in which a microfilter located prior to the detector retains the precipitate formed in the immunochemical reaction. The system used to check the performance of the dynamic approach is monoclonal mouse immunoglobulin G (IgG) as analyte and its corresponding antimouse immunoglobulin G labelled with peroxidase. The derivatizing reaction used to monitor the immunoreaction is based on the oxidation of 4-hydroxyphenylacetic acid with hydrogen peroxide in the presence of the peroxidase bound to the antimouse IgG, which was monitored fluorimetrically (lambda(ex)=315 nm and lambda(em)=425 nm). The method for the determination of monoclonal mouse -IgG shows a linear range between 1 and 200 ng ml(-1) (r(2)=0.9997, n=10) with an RSD less than or equal to 3% at 10 and 100 ng ml(-1) (n=33). The 3 sigma detection limit is 0.1 ng ml(-1). The approach should be generally applicable for the determination of monoclonal antibodies.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 50 条
  • [21] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF PHARMACEUTICALS
    GONZALEZ, F
    TARIN, P
    MASPOCH, S
    BLANCO, M
    ARCHIV DER PHARMAZIE, 1988, 321 (10) : 725 - 728
  • [22] Flow-injection chemiluminescence determination of catecholamines
    Huang, JC
    Zhang, CX
    Zhang, ZJ
    CHINESE CHEMICAL LETTERS, 1998, 9 (09) : 843 - 845
  • [23] DETERMINATION OF CLONAZEPAM BY FLOW-INJECTION ANALYSIS
    LATORRE, C
    BLANCO, MH
    ABAD, EL
    VICENTE, J
    HERNANDEZ, L
    ANALYST, 1988, 113 (02) : 317 - 319
  • [24] SPECTROPHOTOMETRIC DETERMINATION OF PH BY FLOW-INJECTION
    PIA, SH
    WALTMAN, DP
    HILLMAN, DC
    STREET, KW
    ANALYTICA CHIMICA ACTA, 1990, 231 (01) : 21 - 26
  • [25] FLOW-INJECTION SPECTROFLUORIMETRIC DETERMINATION OF PARACETAMOL
    CALATAYUD, JM
    BENITO, CG
    ANALYTICA CHIMICA ACTA, 1990, 231 (02) : 259 - 264
  • [26] Flow-injection chemiluminescence determination of catecholamines
    Wolyniec, Elzbieta
    Niedzwiedzka, Urszula
    Kojlo, Anatol
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2007, 35 (02) : 219 - 231
  • [27] Determination of molybdenum by flow-injection analysis
    Barakat, SA
    Mahmoud, TY
    ACTA CHIMICA SLOVENICA, 2003, 50 (04) : 799 - 806
  • [28] Photometric flow-injection determination of arylamines
    Evgenev, MI
    Evgeneva, II
    Levinson, FS
    INDUSTRIAL LABORATORY, 1996, 62 (01): : 11 - 13
  • [29] FLOW-INJECTION CHEMILUMINESCENCE DETERMINATION OF SULFITE
    ALTAMRAH, SA
    TOWNSHEND, A
    WHEATLEY, AR
    ANALYST, 1987, 112 (06) : 883 - 886
  • [30] DETERMINATION OF PARAQUAT BY FLOW-INJECTION SPECTROPHOTOMETRY