Design and applications of a 4D simulator for respiratory motion

被引:0
|
作者
Ayyangar, K [1 ]
Djajaputra, D [1 ]
Zhen, W [1 ]
Enke, C [1 ]
机构
[1] Univ Nebraska, Med Ctr, Omaha, NE 68182 USA
关键词
D O I
10.1118/1.1997658
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To design, construct, and evaluate a pneumatic respiratory‐motion simulator for 4D radiotherapy. The device should be able to operate in dynamic mode for real‐time simulation of patient breathing motion as well as snapshot mode for static dose measurement. Method and Materials: A simulator incorporating a cylindrical air reservoir with a piston was constructed as a tool in 4D radiotherapy studies. The piston movement is controlled by a programmable logic controller (PLC) which is interfaced to custom software written in Visual Basic (VB). The air reservoir is connected to a lung phantom made of two pulmonary simulation balloons. The pressure inside the lung phantom is monitored by a detector whose input is feedback to the PLC. The lung phantom is immersed in a water‐filled box to simulate the normal tissue surrounding actual human lungs. The box is connected to a water reservoir to allow breathing of the lung phantom. A rubber ball is attached to the inner side of the phantom to simulate a lung tumor and gold seeds are implanted into it for seed‐tracking studies. Spirometer‐based patient respiratory waveform data in ASCII format were obtained from our department's breath‐hold clinical study. The waveform data are input to the VB program and sent to the simulator for controlling the simulation. Results: Preliminary evaluation of the simulator using several patient waveforms has been conducted. The respiratory motion of the lung phantom is found to be reproducible. Conclusion: A prototype respiratory‐motion simulator has been built which should prove valuable for 4D radiotherapy and related studies (gating, respiratory‐induced organ deformation). Its unique design of using pneumatic means to simulate breathing motion allows more realistic simulation studies including those involving animal lung models. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1946 / 1946
页数:1
相关论文
共 50 条
  • [41] Using Respiratory Tumor Motion as a Degree of Freedom to Improve 4D IMRT Plans
    Suh, Y.
    Papiez, L.
    Keall, P.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [42] 4D POSITRON EMISSION TOMOGRAPHY IMAGE RECONSTRUCTION BASED ON BIOMECHANICAL RESPIRATORY MOTION
    Manescu, Petru
    Ladjal, Hamid
    Touileb, Yazid
    Azencot, Joseph
    Beuve, Michael
    Shariat, Behzad
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 99 - 102
  • [43] Respiratory and cardiac motion correction with 4D PET imaging: shooting at moving targets
    Giovanni Lucignani
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 315 - 319
  • [44] 4D digital tomosynthesis for on-board analysis of respiratory induced motion effects
    Maurer, J.
    Wang, Z.
    Zhang, J.
    Yin, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S631 - S631
  • [45] Optimising heart substructure visibility in 4D planning CT by compensating respiratory motion
    van Herk, M.
    Marchant, T.
    Henderson, E.
    McSweeney, D.
    Abravan, A.
    Osorio, E. Vasquez
    McWilliam, A.
    Faivre-Finn, C.
    Price, G.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1381 - S1382
  • [46] Respiratory motion corrected 4D flow using golden radial phase encoding
    Kolbitsch, Christoph
    Bastkowski, Rene
    Schaeffter, Tobias
    Vasquez, Claudia Prieto
    Weiss, Kilian
    Maintz, David
    Giese, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (02) : 635 - 644
  • [48] 4D MR Imaging of Respiratory Organ Motion Using an Intersection Profile Method
    Masuda, Yoshitada
    Haneishi, Hideaki
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [49] Statistical Modeling of 4D Respiratory Lung Motion Using Diffeomorphic Image Registration
    Ehrhardt, Jan
    Werner, Rene
    Schmidt-Richberg, Alexander
    Handels, Heinz
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 251 - 265
  • [50] 4D dose reconstruction using a standard TPS in combination with a respiratory motion model
    Ziegler, M.
    Woelfelschneider, J.
    Prasetio, H.
    Bert, C.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S828 - S829