Purpose: To design, construct, and evaluate a pneumatic respiratory‐motion simulator for 4D radiotherapy. The device should be able to operate in dynamic mode for real‐time simulation of patient breathing motion as well as snapshot mode for static dose measurement. Method and Materials: A simulator incorporating a cylindrical air reservoir with a piston was constructed as a tool in 4D radiotherapy studies. The piston movement is controlled by a programmable logic controller (PLC) which is interfaced to custom software written in Visual Basic (VB). The air reservoir is connected to a lung phantom made of two pulmonary simulation balloons. The pressure inside the lung phantom is monitored by a detector whose input is feedback to the PLC. The lung phantom is immersed in a water‐filled box to simulate the normal tissue surrounding actual human lungs. The box is connected to a water reservoir to allow breathing of the lung phantom. A rubber ball is attached to the inner side of the phantom to simulate a lung tumor and gold seeds are implanted into it for seed‐tracking studies. Spirometer‐based patient respiratory waveform data in ASCII format were obtained from our department's breath‐hold clinical study. The waveform data are input to the VB program and sent to the simulator for controlling the simulation. Results: Preliminary evaluation of the simulator using several patient waveforms has been conducted. The respiratory motion of the lung phantom is found to be reproducible. Conclusion: A prototype respiratory‐motion simulator has been built which should prove valuable for 4D radiotherapy and related studies (gating, respiratory‐induced organ deformation). Its unique design of using pneumatic means to simulate breathing motion allows more realistic simulation studies including those involving animal lung models. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1946 / 1946
页数:1
相关论文
共 50 条
  • [1] THE USE OF A GLOBAL RESPIRATORY MOTION MODEL FOR REAL TIME 4D RADIOTHERAPY APPLICATIONS
    Fayad, H.
    Pan, T.
    Visvikis, D.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S96 - S96
  • [2] Gastrointestinal 4D MRI with Respiratory Motion Correction
    Johansson, A.
    Balter, J.
    Cao, Y.
    MEDICAL PHYSICS, 2018, 45 (06) : E583 - E584
  • [3] Gastrointestinal 4D MRI with respiratory motion correction
    Johansson, Adam
    Balter, James M.
    Cao, Yue
    MEDICAL PHYSICS, 2021, 48 (05) : 2521 - 2527
  • [4] 4D ADAPTIVE MANAGEMENT FOR PATIENT RESPIRATORY MOTION
    Yan, D.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S20 - S21
  • [5] 4D IMRT optimization accommodating respiratory motion
    Joshi, S
    Cullip, T
    Davis, B
    Chang, S
    Keall, P
    Erdi, Y
    Nehmeh, S
    Mageras, G
    Rosenman, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S181 - S181
  • [6] Respiratory motion-conditioned 4D CT: A method to determine respiratory motion tolerances to reduce motion artifacts during 4D CT acquisition
    Vedam, S
    George, R
    Keall, P
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S204 - S205
  • [7] 4D Motion Modeling: Estimation of Respiratory Motion for Radiation Therapy
    Ehrhardt, J.
    Werner, R.
    Schmidt-Richberg, A.
    Handels, H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 2166 - 2169
  • [8] Quantication and analysis of respiratory motion from 4D MRI
    Abd Rahni, Ashrani Aizzuddin
    Lewis, Emma
    Wells, Kevin
    9TH NATIONAL SEMINAR ON MEDICAL PHYSICS (NSMP2014), 2014, 546
  • [9] A Symmetric 4D Registration Algorithm for Respiratory Motion Modeling
    Xu, Huanhuan
    Li, Xin
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2013, PT II, 2013, 8150 : 149 - 156
  • [10] Characterisation of Respiratory Motion Extracted from 4D MRI
    Abd Rahni, Ashrani Aizzuddin
    Lewis, Emma
    Wells, Kevin
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669