Magnesium oxide/water chemical heat pump to enhance energy utilization of a cogeneration system

被引:63
|
作者
Kato, Y [1 ]
Sasaki, Y [1 ]
Yoshizawa, Y [1 ]
机构
[1] Tokyo Inst Technol, Nucl Reactors Res Lab, Meguro Ku, Tokyo 1528550, Japan
关键词
D O I
10.1016/j.energy.2004.08.019
中图分类号
O414.1 [热力学];
学科分类号
摘要
A chemical heat pump using a magnesium oxide/water reaction system is expected to be applicable to cogeneration systems using gas engine, diesel engine, and fuel cells. The operability of the heat pump was examined experimentally under hydration operation pressures between 30 and 203 kPa. In the experiment, a reactant having high durability for repetitive operation was packed in a cylindrical reactor. The cycle of operation was repeated under various thermally driven operation conditions. The forward and reverse reactions were studied by measuring the reactor bed temperature distribution and the reacted fraction changes. The reactor bed stored heat at around 300-400 degrees C by the dehydration reaction and released heat at around 100-200 degrees C by the hydration reaction under the heat amplification mode operation. The practical possibility of the reactor bed was discussed based on the experimental results. The heat pump is expected to be applicable for load leveling in a cogeneration system by chemically storing surplus heat during low heat demand and supplying heat during peak demand. It was shown that the chemical heat pump would be able to improve the efficiency of energy utilization in cogeneration systems while also helping to reduce energy consumption and global carbon dioxide emissions. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2144 / 2155
页数:12
相关论文
共 50 条
  • [21] Effect of Transition Metal Mixing on Reactivities of Magnesium Oxide for Chemical Heat Pump
    Ryu, Junichi
    Takahashi, Rui
    Hirao, Naoya
    Kato, Yukitaka
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2007, 40 (13) : 1281 - 1286
  • [22] Cogeneration Unit with Absorption Heat Pump for DH System
    Dzelzitis, Egils
    Lickrastina, Agnese
    SEVENTH INTERNATIONAL COLD CLIMATE HVAC CONFERENCE, 2012, : 412 - 419
  • [23] Utilization of high temperature heat using a calcium oxide lead oxide carbon dioxide chemical heat pump
    Kato, Y
    Saku, D
    Harada, N
    Yoshizawa, Y
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1997, 30 (06) : 1013 - 1019
  • [24] Utilization of high temperature heat using a calcium oxide/lead oxide/carbon dioxide chemical heat pump
    Res. Laboratory for Nuclear Reactors, Tokyo Institute of Technology, Tokyo 152, Japan
    不详
    J Chem Eng Jpn, 6 (1013-1019):
  • [25] Efficient energy systems on the basis of cogeneration and heat pump technology
    Lucas, K
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2001, 40 (04) : 338 - 343
  • [26] DEVELOPMENT AND TESTING OF THE SULFURIC ACID-WATER CHEMICAL HEAT PUMP/CHEMICAL ENERGY STORAGE SYSTEM.
    Hiller, Carl C.
    Clark E. Charles
    Proceedings of the Intersociety Energy Conversion Engineering Conference, 1979, : 510 - 515
  • [27] Energy Recycling System Using Chemical Heat Pump Container
    Oguraa, Hironao
    2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 : 2048 - 2053
  • [28] Optimum operating conditions of a chemical heat pump using calcium oxide/water reaction for effective utilization of surplus electricity
    Fujimoto, S
    Ogura, H
    Iwamoto, H
    Abe, M
    Kage, H
    Matsuno, Y
    Baba, S
    Muta, S
    KAGAKU KOGAKU RONBUNSHU, 2003, 29 (01) : 20 - 26
  • [29] Thermal performance of a packed bed reactor of a chemical heat pump for cogeneration
    Kato, Y
    Takahashi, F
    Watanabe, A
    Yoshizawa, Y
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2000, 78 (A5): : 745 - 748
  • [30] Gas-fired cogeneration system incorporating heat pump
    Geng, KC
    Fu, L
    Tian, GS
    Jiang, Y
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 703 - 707