Performance of silicon-drift detectors in kaonic atom X-ray measurements

被引:23
|
作者
Bazzi, M. [2 ]
Beer, G. [3 ]
Bombelli, L. [4 ]
Bragadireanu, A. M. [2 ,5 ]
Cargnelli, M. [1 ]
Corradi, G. [2 ]
Curceanu , C. [2 ]
d'Uffizi, A. [2 ]
Fiorini, C. [4 ]
Frizzi, T. [4 ]
Ghio, F. [6 ,7 ]
Girolami, B. [6 ,7 ]
Guaraldo, C. [2 ]
Hayano, R. S. [8 ]
Iliescu, M. [2 ]
Ishiwatari, T. [1 ]
Iwasaki, M. [9 ]
Kienle, P. [1 ,10 ]
Sandri, P. Levi [2 ]
Longoni, A. [4 ]
Lucherini, V. [2 ]
Marton, J. [1 ]
Okada, S. [2 ]
Pietreanu, D. [2 ]
Ponta, T. [5 ]
Rizzo, A. [2 ]
Vidal, A. Romero [2 ]
Scordo, A. [2 ]
Shi, H. [8 ]
Sirghi, D. L. [2 ,5 ]
Sirghi, F. [2 ,5 ]
Tatsuno, H. [8 ]
Tudorache, A. [5 ]
Tudorache, V. [5 ]
Doce, O. Vazquez [2 ]
Widmann, E. [1 ]
Zmeskal, J. [1 ]
机构
[1] Stefan Meyer Inst Subatomare Phys, Vienna, Austria
[2] Ist Nazl Fis Nucl, Lab Nazl Frascati, Rome, Italy
[3] Univ Victoria, Dept Phys & Astron, Victoria, BC, Canada
[4] Politech Milano, Sez Elettron, Milan, Italy
[5] IFIN HH, Bucharest, Romania
[6] Ist Nazl Fis Nucl, Sez Roma 1, Rome, Italy
[7] Inst Super Sanita, Rome, Italy
[8] Univ Tokyo, Tokyo, Japan
[9] Inst Phys & Chem Res, RIKEN, Saitama, Japan
[10] Tech Univ Munich, Phys Dep, D-8046 Garching, Germany
关键词
Silicon drift detector; X-ray detector; Kaonic atoms;
D O I
10.1016/j.nima.2010.06.332
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Large-area silicon drift detectors (SDDs) were used for the first time in the background condition of a collider for precision spectroscopy of the kaonic atom X-rays in the SIDDHARTA experiment for the study of the strong interaction in a low-energy regime. The measurements were performed at the DA Phi NE electron-positron collider (LNF, Italy), using gas targets of hydrogen, deuterium, helium-3, and helium-4. A test measurement using the kaonic He-4 X-rays showed an excellent performance of the SDD devices under the beam conditions, and a good background suppression capability using the time correlation between the kaonic atom X-rays and the back-to-back correlated K+ K- pairs produced by phi decays. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:264 / 267
页数:4
相关论文
共 50 条
  • [41] Development of 32-channel silicon drift detectors and digital electronics for X-ray spectroscopy
    Gauthier, Christophe
    Goujon, Gerard
    Goulon, Jose
    Moguiline, Eric
    Dressier, Pierre
    Henck, Roland
    Lampert, Marie-Odile
    Journal of Synchrotron Radiation, 1998, 5 (03): : 863 - 865
  • [42] X-ray 2-D position-sensing with multilinear silicon drift detectors
    Castoldi, A
    Galimberti, A
    Gatti, E
    Guazzoni, C
    Rehak, P
    Strüder, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (02) : 601 - 606
  • [43] New X-Ray Detectors for Exotic Atom Research
    Marton, Johann
    Cargnelli, M.
    Ishiwatari, T.
    Kienle, P.
    Nikolics, K.
    Widmann, E.
    Zmeskal, J.
    Bazzi, M.
    Catitti, M.
    Curceanu , C.
    Guaraldo, C.
    Iliescu, M.
    Sandri, P. Levi
    Lucherini, V.
    Okada, S.
    Pietreanu, D.
    Vidal, A. Romero
    Scordo, A.
    Sirghi, D. L.
    Sirghi, F.
    Doce, O. Vazquez
    Beer, G.
    Bombelli, L.
    Fiorini, C.
    Frizzi, T.
    Longoni, A.
    Bragadireanu, A. M.
    Ponta, T.
    Ghio, F.
    Girolami, B.
    Hayano, R.
    Tatsuno, H.
    Xe-Hi, S.
    Iwasaki, M.
    Lechner, P.
    Soltau, H.
    Strueder, L.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 1400 - 1404
  • [44] Development of 32-channel silicon drift detectors and digital electronics for X-ray spectroscopy
    Gauthier, C
    Goujon, G
    Goulon, J
    Moguiline, E
    Dressler, P
    Henck, R
    Lampert, MO
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 863 - 865
  • [45] A Multichannel Integrated Readout Circuit for High Throughput X-Ray Spectroscopy With Silicon Drift Detectors
    Bombelli, L.
    Quaglia, R.
    Fiorini, C.
    Alberti, R.
    Frizzi, T.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 430 - 436
  • [46] Large area silicon drift detectors system for high precision timed x-ray spectroscopy
    Miliucci, M.
    Iliescu, M.
    Sgaramella, F.
    Bazzi, M.
    Bosnar, D.
    Bragadireanu, M.
    Carminati, M.
    Cargnelli, M.
    Clozza, A.
    Curceanu, C.
    Deda, G.
    De Paolis, L.
    Del Grande, R.
    Fiorini, C.
    Guaraldo, C.
    Iwasaki, M.
    King, P.
    Sandri, P. Levi
    Marton, J.
    Moskal, P.
    Napolitano, F.
    Niedzwiecki, S.
    Piscicchia, K.
    Scordo, A.
    Shi, H.
    Silarski, M.
    Sirghi, D.
    Sirghi, F.
    Skurzok, M.
    Spallone, A.
    Tuechler, M.
    Doce, O. Vazquez
    Zmeskal, J.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (09)
  • [47] A Multichannel Integrated Readout Circuit for High Throughput X-ray Spectroscopy with Silicon Drift Detectors
    Bombelli, L.
    Quaglia, R.
    Fiorini, C.
    Tocchio, A.
    Alberti, R.
    Frizzi, T.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 944 - 950
  • [48] A monolithic array of 77 Silicon Drift Detectors for X-ray spectroscopy and gamma-ray imaging applications
    Fiorini, C
    Bellini, M
    Gola, A
    Longoni, A
    Perotti, E
    Lechner, P
    Soltau, H
    Strüder, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 1165 - 1170
  • [49] A monolithic array of 77 silicon drift detectors for X-ray spectroscopy and gamma-ray imaging applications
    Fiorini, C
    Bellini, M
    Gola, A
    Longoni, A
    Perotti, F
    Lechner, P
    Soltau, H
    Strüder, L
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1324 - 1326
  • [50] Hard X-ray and Gamma-ray Imaging and Spectroscopy using Scintillators coupled to Silicon Drift Detectors
    Lechner, P.
    Eckhard, R.
    Fiorini, C.
    Gola, A.
    Longoni, A.
    Niculae, A.
    Peloso, R.
    Soltau, H.
    Strueder, L.
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY III, 2008, 7021