Three-dimensional planning and use of patient-specific instrumentation (PSI) in total shoulder arthroplasty

被引:0
|
作者
Schmalzl, J. [1 ]
Gerhardt, C. [2 ]
Lehmann, L. J. [2 ]
机构
[1] Univ Klin Wurzburg, Klin & Poliklin Unfall Hand Plast & Wiederherstel, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] ViDia Kliniken, St Vincentius Klin, Abt Unfall & Handchirurg, Karlsruhe, Germany
关键词
Glenoid defect; Schulter prosthesis; Osteoarthritis; Glenoid; Base plate; GLENOID COMPONENT POSITION; ACCURACY; IMPLANTATION; FORCES; GUIDE;
D O I
10.1007/s00142-021-00482-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
Three-dimensional (3D) templating of the glenoid in total shoulder arthroplasty allows for more accurate planning and better positioning of the glenoid component through an improved understanding of the pathologic glenoid morphology, version, and inclination in reference to an idealized calculated glenoid position. Loosening of the glenoid component remains the most common mode of late failure after anatomic total shoulder arthroplasty. Reasons for malposition of the glenoid component might be inaccurate assessment of the pathologic anatomy of the glenoid, incorrect choice and/or position of the implant to correct the pathologic condition, and inaccurate surgical execution of the preoperative plan. Because of the limitations of standard radiographs, many surgeons use two-dimensional (2D) CT scans to evaluate glenoid morphology and version. However, multiple studies have shown that 3D CT scans are more accurate and reliable than 2D scans, particularly in the face of advanced osseous defects. With the use of 3D CT templating, the surgeon can select the implant and define the optimal placement of that implant to correct the pathologic condition. We describe the available commercial systems used for advanced 3D CT templating, the principles of planning and the procedure.
引用
下载
收藏
页码:358 / 365
页数:8
相关论文
共 50 条
  • [1] Three-dimensional planning and use of patient-specific instrumentation (PSI) in total shoulder arthroplasty
    Schmalzl, J.
    Gerhardt, C.
    Lehmann, L. J.
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2020, 15 (03): : 179 - 186
  • [2] Patient-specific instrumentation for total shoulder arthroplasty
    Gomes, Nuno Sampaio
    EFORT OPEN REVIEWS, 2016, 1 (05): : 177 - 182
  • [3] Dreidimensionale Planung und Verwendung patientenspezifischer Instrumentierung (PSI) in der SchultertotalendoprothetikThree-dimensional planning and use of patient-specific instrumentation (PSI) in total shoulder arthroplasty
    J. Schmalzl
    C. Gerhardt
    L. J. Lehmann
    Obere Extremität, 2020, 15 (3) : 179 - 186
  • [4] Dreidimensionale Planung und Verwendung patientenspezifischer Instrumentierung (PSI) in der SchultertotalendoprothetikThree-dimensional planning and use of patient-specific instrumentation (PSI) in total shoulder arthroplasty
    J. Schmalzl
    C. Gerhardt
    L. J. Lehmann
    Arthroskopie, 2021, 34 (5) : 358 - 365
  • [5] Three-dimensional planning, navigation, patient-specific instrumentation and mixed reality in shoulder arthroplasty: a digital orthopedic renaissance
    Kolac, Ulas Can
    Paksoy, Alp
    Akguen, Doruk
    EFORT OPEN REVIEWS, 2024, 9 (06) : 517 - 527
  • [6] Accuracy of 3-Dimensional Planning, Implant Templating, and Patient-Specific Instrumentation in Anatomic Total Shoulder Arthroplasty
    Iannotti, Joseph P.
    Walker, Kyle
    Rodriguez, Eric
    Patterson, Thomas E.
    Jun, Bong-Jae
    Ricchetti, Eric T.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (05): : 446 - 457
  • [7] Patient-specific instrumentation (PSI) in total ankle arthroplasty: a systematic review
    Qiuyuan Wang
    Nianfei Zhang
    Wanshou Guo
    Weiguo Wang
    Qidong Zhang
    International Orthopaedics, 2021, 45 : 2445 - 2452
  • [8] Patient-specific instrumentation (PSI) in total ankle arthroplasty: a systematic review
    Wang, Qiuyuan
    Zhang, Nianfei
    Guo, Wanshou
    Wang, Weiguo
    Zhang, Qidong
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (09) : 2445 - 2452
  • [9] Patient-specific instrumentation for total shoulder arthroplasty: not as accurate as it would seem
    Lau, Simon C.
    Keith, Prue P. A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (01) : 90 - 95
  • [10] Accuracy of patient-specific instrumentation in anatomic and reverse total shoulder arthroplasty
    Dallalana, Richard James
    McMahon, Ryan A.
    East, Ben
    Geraghty, Liam
    INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2016, 10 (02): : 59 - 66