Cervical spine movement during laryngoscopy using the Airway Scope compared with the Macintosh laryngoscope

被引:49
|
作者
Hirabayashi, Y.
Fujita, A.
Seo, N.
Sugimoto, H.
机构
[1] Jichi Med Univ, Dept Anaesthesiol & Crit Care Med, Shimotsuke, Tochigi 3290498, Japan
[2] Jichi Med Univ, Dept Radiol, Shimotsuke, Tochigi 3290498, Japan
关键词
D O I
10.1111/j.1365-2044.2007.05188.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The Airway Scope is a new rigid laryngoscope. This intubation device provides a non-line-of sight view of the glottis. A non-line-of sight view is expected to cause less movement of the cervical spine during laryngeal visualisation. We compared the degree of cervical spine movement during laryngoscopy with the Airway Scope and conventional direct laryngoscope. Twenty patients requiring general anaesthesia and tracheal intubation were studied. Movements of the cervical spine were measured using radiography in the same patient during laryngoscopy with the Airway Scope and a Macintosh laryngoscope. Cervical spine movement during laryngoscopy with the Airway Scope was 37%, 37% and 68% less than that with the Macintosh laryngoscope at the C0/C1, C1/C2 and C3/C4 motion segments, respectively (p < 0.05). The movement of the atlanto-occipital distance using the Airway Scope was 42% less than that during laryngoscopy using the Macintosh laryngoscope (p < 0.05). Laryngoscopy using the Airway Scope involves less movement of the cervical spine compared to conventional laryngoscopy using the Macintosh laryngoscope.
引用
收藏
页码:1050 / 1055
页数:6
相关论文
共 50 条
  • [41] Comparison of haemodynamic responses to tracheal intubation using the Airway Scope® and Macintosh laryngoscope in normotensive and hypertensive patients
    Koyama, Y.
    Nishihama, M.
    Inagawa, G.
    Kamiya, Y.
    Miki, T.
    Kurihara, R.
    Goto, T.
    ANAESTHESIA, 2011, 66 (10) : 895 - 900
  • [42] Measurement of forces applied using a Macintosh direct laryngoscope compared with a Glidescope video laryngoscope in patients with predictors of difficult laryngoscopy A randomised controlled trial
    Cordovani, Daniel
    Russell, Twain
    Wee, Wallace
    Suen, Andrew
    Cooper, Richard M.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2019, 36 (03) : 221 - 226
  • [43] Cervical spine movements during laryngoscopy
    Gupta, K
    Frerk, C
    ANAESTHESIA, 1999, 54 (10) : 1012 - 1012
  • [44] Three-dimensional cervical spine movement during intubation using the Macintosh and BullardTM laryngoscopes, the bonfils fibrescope and the intubating laryngeal mask airway
    Wahlen, BM
    Gercek, E
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (11) : 907 - 913
  • [45] Intubation with King Vision® video laryngoscope and Macintosh laryngoscope in cervical spine injured: A randomized controlled trial
    Kumar, Mohit
    Gupta, Abhinav
    Mahajan, Harikishan
    Dhanerwa, Ravinder
    Chauhan, Parashuram
    INDIAN ANAESTHETISTS FORUM, 2019, 20 (02): : 89 - 94
  • [46] Efficacy of Coopdech videolaryngoscope: comparisons with a Macintosh laryngoscope and the Airway Scope in a manikin with difficult airways
    Tomoyuki Saito
    Takashi Asai
    Takero Arai
    Mayumi Tachikawa
    Mutsuhisa Shimazaki
    Yasuhisa Okuda
    Journal of Anesthesia, 2012, 26 : 617 - 620
  • [47] Efficacy of Coopdech videolaryngoscope: comparisons with a Macintosh laryngoscope and the Airway Scope in a manikin with difficult airways
    Saito, Tomoyuki
    Asai, Takashi
    Arai, Takero
    Tachikawa, Mayumi
    Shimazaki, Mutsuhisa
    Okuda, Yasuhisa
    JOURNAL OF ANESTHESIA, 2012, 26 (04) : 617 - 620
  • [48] Performance of a Pentax-Airway scope and a Macintosh laryngoscope for difficult intubation in a manikin study
    Xue, F. S.
    Liao, X.
    Yuan, Y. J.
    Liu, J. H.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (07) : 900 - 901
  • [49] Tracheal intubation by non-anesthesia residents using the Pentax-AWS airway scope and Macintosh laryngoscope
    Hirabayashi, Yoshihiro
    Seo, Norimasa
    JOURNAL OF CLINICAL ANESTHESIA, 2009, 21 (04) : 268 - 271
  • [50] Comparison of C-MAC, McGrath and Macintosh laryngoscope use in a standardized airway manikin with immobilized cervical spine by novice intubators
    Reyhan, N.
    Goksu, E.
    Kaplan, A.
    Senfer, A.
    Sevil, H.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (09): : 1368 - 1370