Multi-beam X-ray source breast tomosynthesis reconstruction with different algorithms

被引:5
|
作者
Zhou, Weihua [1 ]
Qian, Xin [3 ,4 ]
Lu, Jianping [3 ,4 ,5 ]
Zhou, Otto [3 ,4 ,5 ]
Chen, Ying [1 ,2 ]
机构
[1] So Illinois Univ, Dept Elect & Comp Engn, Carbondale, IL 62901 USA
[2] So Illinois Univ, Biomed Engn Grad Program, Carbondale, IL 62901 USA
[3] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[4] Univ N Carolina, Dept Curriculum Appl Sci & Engn, Chapel Hill, NC 27599 USA
[5] Univ N Carolina, Lineberger Comprehen Cancer Ctr, Chapel Hill, NC 27599 USA
关键词
mammography; tomosynthesis; carbon-nanotube; back projection (BP); filtered back projection (FBP); matrix inversion tomosynthesis (MITS); maximum likelihood expectation maximization (MLEM); simultaneous algebraic reconstruction technique (SART); ART;
D O I
10.1117/12.844295
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Digital breast tomosynthesis is a new technique to improve the early detection of breast cancer by providing three-dimensional reconstruction volume of the object with limited-angle projection images. This paper investigated the image reconstruction with a standard biopsy training breast phantom using a novel multi-beam X-ray sources breast tomosynthesis system. Carbon nanotube technology based X-ray tubes were lined up along a parallel-imaging geometry to decrease the motion blur. Five representative reconstruction algorithms, including back projection (BP), filtered back projection (FBP), matrix inversion tomosynthesis (MITS), maximum likelihood expectation maximization (MLEM) and simultaneous algebraic reconstruction technique (SART), were investigated to evaluate the image reconstruction of the tomosynthesis system. Reconstructed images of the masses and micro-calcification clusters embedded in the phantom were studied. The evaluated multi-beam X-ray breast tomosynthesis system is able to generate three-dimensional information of the breast phantom with clearly-identified regions of the masses and calcifications. Future study will be done soon to further improve the imaging parameters' measurement and reconstruction.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] The Enhancement of the Linear X-Ray Tomography with Digital Tomosynthesis Algorithms
    Senchurov, Sergiy
    Motolyga, Olexander
    2013 IEEE XXXIII INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2013, : 319 - 321
  • [42] Geometry calibration between X-ray source and detector for tomosynthesis with a portable X-ray system
    Sato, Kohei
    Ohnishi, Takashi
    Sekine, Masashi
    Haneishi, Hideaki
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2017, 12 (05) : 707 - 717
  • [43] Geometry calibration between X-ray source and detector for tomosynthesis with a portable X-ray system
    Kohei Sato
    Takashi Ohnishi
    Masashi Sekine
    Hideaki Haneishi
    International Journal of Computer Assisted Radiology and Surgery, 2017, 12 : 707 - 717
  • [44] Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging
    Yudong Yao
    Yi Jiang
    Jeffrey A. Klug
    Michael Wojcik
    Evan R. Maxey
    Nicholas S. Sirica
    Christian Roehrig
    Zhonghou Cai
    Stefan Vogt
    Barry Lai
    Junjing Deng
    Scientific Reports, 10
  • [45] HIGH RESOLUTION X-RAY MULTI-BEAM DIFFRACTION STUDIES OF THIN FILM AND INTERFACES
    Kovalchuk, M. V.
    Samoilova, L.
    Kreines, A.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1999, 55 : 500 - 500
  • [46] A multi-beam X-ray imaging detector using a branched optical fiber bundle
    Yashiro, Wataru
    Shirasawa, Tetsuroh
    Kamezawa, Chika
    Voegeli, Wolfgang
    Arakawa, Etsuo
    Kajiwara, Kentaro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59 (03)
  • [47] Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging
    Yao, Yudong
    Jiang, Yi
    Klug, Jeffrey A.
    Wojcik, Michael
    Maxey, Evan R.
    Sirica, Nicholas S.
    Roehrig, Christian
    Cai, Zhonghou
    Vogt, Stefan
    Lai, Barry
    Deng, Junjing
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [48] X-RAY STANDING WAVE METHOD UNDER MULTI-BEAM DIFFRACTION CONDITION.
    Kovalchuk, M. V.
    Samoilova, L.
    Kreines, A.
    Zozulja, A.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1999, 55 : 531 - 531
  • [49] X-ray source motion blur modeling and deblurring with generative diffusion for digital breast tomosynthesis
    Gao, Mingjie
    Fessler, Jeffrey A.
    Chan, Heang-Ping
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (11):
  • [50] X-ray source array optimization for mobile chest tomosynthesis
    Inscoe, Christina
    Billingsley, Alex
    Zhao, Alan
    Burel, Heaven Laramy-Jade
    Chesser, Stephen
    Lyda, Gavin
    Lu, Jianping
    Lee, Yueh
    Zhou, Otto
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925