Temperature analysis of steel -: Concrete composite slim floor structures exposed to fire

被引:0
|
作者
Ma, ZC [1 ]
Mäkeläinen, P [1 ]
机构
[1] Helsinki Univ Technol, Dept Civil & Environm Engn, Lab Steel Struct, FIN-02015 Helsinki, Finland
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a heat transfer model to calculate the temperature of composite slim floor beams exposed to tire. The interface thermal resistance between concrete and steel and the effect of fire protection can be accounted for in this model. Using this model, the fire resistance of the composite slim floor beams can be calculated and the effects of the significant parameters such as load ratio, section size of the beam, additional reinforcement and fire protection can be evaluated without the necessity of testing.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 50 条
  • [31] Large scale fire test on a composite slim-floor system
    Bailey, CG
    STEEL & COMPOSITE STRUCTURES, 2003, 3 (03) : 153 - 168
  • [32] Effect of Load Ratios on the Behavior of Asymmetric Slim Floor Beams Exposed to Fire
    Park, Sooyoung
    Kim, Heungyoul
    Hong, Kappyo
    FIRE TECHNOLOGY, 2013, 49 (04) : 907 - 926
  • [33] The influence of tensile membrane action on fire-exposed composite concrete floor-steel beams with web-openings
    Wong, Bernice V. Y.
    Burgess, Ian W.
    9TH ASIA-OCEANIA SYMPOSIUM ON FIRE SCIENCE AND TECHNOLOGY, 2013, 62 : 710 - 716
  • [34] Effect of Load Ratios on the Behavior of Asymmetric Slim Floor Beams Exposed to Fire
    Sooyoung Park
    Heungyoul Kim
    Kappyo Hong
    Fire Technology, 2013, 49 : 907 - 926
  • [35] Numerical analysis of composite slim floor beams with un-symmetry steel sections
    Jiang Su Key Laboratory of Structure Engineering, University of Science and Technology of Suzhou, Suzhou 215011, China
    Harbin Gongye Daxue Xuebao, 2007, SUPPL. 2 (241-243):
  • [36] Restraint of fire-exposed concrete floor systems
    Lim, L
    Buchanan, AH
    Moss, PJ
    FIRE AND MATERIALS, 2004, 28 (2-4) : 95 - 125
  • [37] Design of stud connections in steel - concrete composite structures in fire situation
    Larrua, Yisel
    Larrua, Rafael
    Silva, Valdir P.
    REVISTA INGENIERIA DE CONSTRUCCION, 2015, 30 (01): : 39 - 52
  • [38] Shear resistance of concrete dowels in composite slim-floor beams
    Aggelopoulos, Eleftherios
    Schorr, Johannes
    Kuhlmann, Ulrike
    ce/papers, 2021, 4 (2-4) : 772 - 780
  • [39] Fire performance research and application on steel-concrete composite structures
    Yu, Zhiwu
    Ding, Faxing
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2010, 31 (06): : 96 - 109
  • [40] Modelling of Steel-Concrete Composite Structures in Fire Using OpenSees
    Jiang, Jian
    Usmani, Asif
    Li, Guo-Qiang
    ADVANCES IN STRUCTURAL ENGINEERING, 2014, 17 (02) : 249 - 264