The Novel TEM Sample Preparations Technique for Long Dimension Trench

被引:0
|
作者
Chou, Po Fu [1 ]
Fang, Shu Mei [1 ]
机构
[1] United Microelect Corp Ltd, Hsinchu 300, Taiwan
来源
2011 18TH IEEE INTERNATIONAL SYMPOSIUM ON THE PHYSICAL AND FAILURE ANALYSIS OF INTEGRATED CIRCUITS (IPFA) | 2011年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel ex-situ sample preparation technique is introduced in this paper. By thinning a deep trench or high aspect ratio structure perpendicular to the long dimension (i.e., from the side) to instead of thinning from perpendicular to the short dimension (either the top or the bottom), it is possible to obtain a more uniformly thin TEM specimen over the entire long dimension of the structure. This article will describe the sample preparation procedure and show some case studies to demonstrate the capability of this technique.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] A Filtration Based Technique for Simultaneous SEM and TEM Sample Preparation for the Rapid Detection of Pathogens
    Beniac, Daniel R.
    Siemens, Christine G.
    Wright, Christine J.
    Booth, Tim F.
    VIRUSES-BASEL, 2014, 6 (09): : 3458 - 3471
  • [22] A NOVEL TECHNIQUE FOR EFFICIENT MULTIPLE SAMPLE DIALYSIS
    FARMER, PK
    TYLER, JM
    LONG, PA
    KENT, PG
    STACHURA, ME
    ANALYTICAL BIOCHEMISTRY, 1983, 135 (01) : 193 - 196
  • [23] Kinks on partials of 60° dislocations in silicon as revealed by a novel TEM technique
    Alexander, H
    Kolar, HR
    Spence, JCH
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1999, 171 (01): : 5 - 16
  • [24] Novel in-situ lamella fabrication technique for in-situ TEM
    Canavan, Megan
    Daly, Dermot
    Rummel, Andreas
    McCarthy, Eoin K.
    McAuley, Cathal
    Nicolosi, Valeria
    ULTRAMICROSCOPY, 2018, 190 : 21 - 29
  • [25] Detailed investigation of SEM-results by TEM at one sample using FIB-technique
    Muhle, U
    Wiesner, A
    Schray, S
    MICROELECTRONICS AND RELIABILITY, 1998, 38 (6-8): : 895 - 899
  • [26] Detailed investigation of SEM-results by TEM at one sample using FIB-technique
    Muehle, U.
    Wiesner, A.
    Schray, S.
    Microelectronics Reliability, 1998, 38 (6-8): : 895 - 899
  • [27] Silicon Defect Observation From Ultra-Thick Sample Using TEM EELS Technique
    Li Lee, Gek
    Lee, Kok Wah
    Zhu, Jie
    2021 IEEE INTERNATIONAL SYMPOSIUM ON THE PHYSICAL AND FAILURE ANALYSIS OF INTEGRATED CIRCUITS (IPFA), 2021,
  • [28] USE OF A NOVEL SAMPLE MODULATION TECHNIQUE IN FLAME SPECTROMETRY
    BOJOVIC, V
    ANTICJOV.A
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1972, B 27 (09) : 385 - &
  • [29] A NOVEL, SENSITIVE FLUOROMETRIC STAINING TECHNIQUE FOR THE DETECTION OF DNA IN RNA PREPARATIONS
    MOCHARLA, R
    MOCHARLA, H
    HODES, ME
    NUCLEIC ACIDS RESEARCH, 1987, 15 (24) : 10589 - 10589
  • [30] A novel technique for fabricating high reliable trench DMOSFETs using self-align technique and hydrogen annealing
    Kim, J
    Roh, TM
    Kim, SG
    Park, IY
    Lee, B
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2003, 50 (02) : 378 - 383