Electromagnetic interference of implantable unipolar cardiac pacemakers by an induction oven

被引:17
|
作者
Hirose, M [1 ]
Hida, M
Sato, E
Kokubo, K
Nie, M
Kobayashi, H
机构
[1] Kitasato Univ, Sch Allied Hlth Sci, Dept Clin Engn, Sagamihara, Kanagawa 2288555, Japan
[2] Dokkyo Med Univ Hosp, Mibu, Tochigi, Japan
[3] Eastern Japan Med Ctr, Cardiovasc Med Ctr, Kanagawa, Japan
来源
关键词
pacemaker; electromagnetic interference; induction oven; pacing;
D O I
10.1111/j.1540-8159.2005.09565.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Induction ovens have been reported to exert electromagnetic interference on implanted cardiac pacemakers. In an attempt to quantitatively investigate the electromagnetic interference caused by an induction oven on implantable unipolar cardiac pacemakers, we measured the distribution profile of the magnetic field intensity, both with and without a pan on the induction oven. We also performed the inhibition test and asynchronous test using four kinds of pacemakers housed in the standardized Irnich human body model, and measured the maximal distance from the induction oven up to which the interference occurred. In the pan-detection mode of the oven in the absence of a pan, the distribution profile of the magnetic field intensity peaked at the center of the cooking plate, and during induction heating of a pan placed on the induction oven, it was the largest at the circular top-edge of the pan. Pacemaker pulses were inhibited by the induction oven, or generated by the reversion mechanism. The maximal interference distance from the oven was 34 cm for one of the pacemakers. Thus, the safe distance from an induction oven of a patient with an implanted cardiac pacemaker is considered to be 50 cm or more. In conclusion, in the pan-detection mode of the oven in the absence of a pan, the distribution profile of the magnetic field intensity peaked at the center of the cooking plate, and during the induction heating of a pan placed on the oven, it peaked at the circular edge of the pan. The induction oven asynchronized or generated pulses in implantable unipolar cardiac pacemakers up to a maximal distance of 34 cm from the induction oven.
引用
收藏
页码:540 / 548
页数:9
相关论文
共 50 条
  • [1] Electromagnetic interference with implantable cardiac pacemakers by video capsule
    Dubner, S
    Dubner, Y
    Gallino, S
    Spallone, L
    Zagalsky, D
    Rubio, H
    Zimmerman, J
    Goldin, E
    [J]. GASTROINTESTINAL ENDOSCOPY, 2005, 61 (02) : 250 - 254
  • [2] ANALYSIS OF THE COUPLING OF ELECTROMAGNETIC-INTERFERENCE TO UNIPOLAR CARDIAC-PACEMAKERS
    SMITH, GS
    TOLER, JC
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1981, 19 (01) : 97 - 109
  • [3] ELECTROMAGNETIC-INTERFERENCE IN IMPLANTABLE PACEMAKERS
    IRNICH, W
    DEBAKKER, JMT
    BISPING, HJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1978, 1 (01): : 52 - 61
  • [4] Electromagnetic Interference of Avalanche Transceivers with Cardiac Pacemakers and Implantable Cardioverter Defibrillators
    Dorenkamp, Marc
    Blaschke, Florian
    Voigt, Kathleen
    Fleck, Eckart
    Goetze, Stephan
    Roser, Mattias
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (08): : 931 - 938
  • [5] INTERFERENCE SENSITIVITY OF IMPLANTABLE CARDIAC PACEMAKERS
    BLASER, R
    SCHALDAC.M
    KIRSCH, U
    DITTRICH, H
    [J]. LANGENBECKS ARCHIV FUR CHIRURGIE, 1971, 329 : 607 - &
  • [6] Electromagnetic interference: Pacemakers, cardiac resynchronization therapy devices, implantable cardioverter–defibrillator
    Nowak B.
    Przibille O.
    Napp A.
    [J]. Herzschrittmachertherapie + Elektrophysiologie, 2022, 33 (3) : 297 - 304
  • [7] X-ray Radiation Causes Electromagnetic Interference in Implantable Cardiac Pacemakers
    Hirose, Minoru
    Tachikawa, Keiichi
    Ozaki, Masanori
    Umezawa, Naoki
    Shinbo, Toshihiro
    Kokubo, Kenichi
    Kobayashi, Hirosuke
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (10): : 1174 - 1181
  • [8] Electromagnetic interference with cardiac pacemakers and implantable cardioverter-defibrillators from low-frequency electromagnetic fields in vivo
    Tiikkaja, Maria
    Aro, Aapo L.
    Alanko, Tommi
    Lindholm, Harri
    Sistonen, Heli
    Hartikainen, Juha E. K.
    Toivonen, Lauri
    Juutilainen, Jukka
    Hietanen, Maila
    [J]. EUROPACE, 2013, 15 (03): : 388 - 394
  • [9] Interference of programmed electromagnetic stimulation with pacemakers and automatic implantable cardioverter defibrillators
    Gwechenberger, Marianne
    Rauscha, Friedrich
    Stix, Guenter
    Schmid, Gernot
    Strametz-Juranek, Jeanette
    [J]. BIOELECTROMAGNETICS, 2006, 27 (05) : 365 - 377
  • [10] IMPLANTABLE CARDIAC PACEMAKERS
    GREEN, GD
    [J]. LANCET, 1971, 1 (7705): : 919 - &