Electromagnetic interference: Pacemakers, cardiac resynchronization therapy devices, implantable cardioverter–defibrillator

被引:2
|
作者
Nowak B. [1 ]
Przibille O. [1 ]
Napp A. [2 ]
机构
[1] Cardioangiologisches Centrum Bethanien, Im Prüfling 23, Frankfurt a.M.
[2] Medizinische Klinik I, – Kardiologie, Angiologie und Internistische Intensivmedizin, Uniklinik RWTH Aachen, Pauwelsstraße 30, Aachen
关键词
Cardiac arrhythmias; Cardiac implantable electronic devices; Cardiac pacemaker; Electromagnetic fields; Electromagnetic interference;
D O I
10.1007/s00399-022-00875-7
中图分类号
学科分类号
摘要
Patients with cardiac pacemakers, implantable cardioverter–defibrillators (ICDs), and cardiac resynchronization therapy devices (CRT) are exposed to different types of electromagnetic interference (EMI) at home and at work. Due to the constantly increasing role of electrically active appliances in daily use and the introduction of new therapy concepts such as the leadless cardiac pacemaker and the subcutaneous defibrillator, this topic is of great relevance. The further development of the implanted devices and the almost complete use of bipolar leads has reduced the overall risk of EMI. This review article provides information about the current status of possible interference in the private environment and how to avoid it. In addition, information is provided on how to deal with occupational sources of interference. © 2022, The Author(s), under exclusive licence to Springer Medizin Verlag GmbH, ein Teil von Springer Nature.
引用
收藏
页码:297 / 304
页数:7
相关论文
共 50 条
  • [1] Indications for Pacemakers, Implantable Cardioverter-Defibrillator and Cardiac Resynchronization Devices
    Samii, Soraya M.
    MEDICAL CLINICS OF NORTH AMERICA, 2015, 99 (04) : 795 - +
  • [3] Cardiac Implantable Electronic Device Therapy Permanent Pacemakers, Implantable Cardioverter Defibrillators, and Cardiac Resynchronization Devices
    Steffen, Melanie M.
    Osborn, Jeffery S.
    Cutler, Michael J.
    MEDICAL CLINICS OF NORTH AMERICA, 2019, 103 (05) : 931 - +
  • [4] Prevalence of electromagnetic interference from left ventricular assist devices in patients with implantable cardioverter defibrillator/pacemakers
    Kooij, C.
    Yalcin, Y. C.
    Theuns, D. A. M. J.
    Constantinescu, A. A.
    Brugts, J. J.
    Manintveld, O. C.
    Yap, S. C.
    Szili-Torok, T.
    Bogers, A. J. J. C.
    Caliskan, K.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3306 - 3306
  • [5] Cardiac resynchronization therapy in combination with implantable cardioverter-defibrillator
    Daubert, J. Claude
    Leclercq, Christophe
    Mabo, Philippe
    EUROPACE, 2009, 11 : 87 - 92
  • [6] Electromagnetic Interference of Avalanche Transceivers with Cardiac Pacemakers and Implantable Cardioverter Defibrillators
    Dorenkamp, Marc
    Blaschke, Florian
    Voigt, Kathleen
    Fleck, Eckart
    Goetze, Stephan
    Roser, Mattias
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (08): : 931 - 938
  • [7] Cardiac resynchronization and implantable cardioverter defibrillator therapy:: Preliminary results from the InSync Implantable Cardioverter Defibrillator Italian Registry
    Gasparini, M
    Lunati, M
    Bocchiardo, M
    Mantica, M
    Gronda, E
    Frigerio, M
    Caponi, D
    Carboni, A
    Boriani, G
    Zanotto, G
    Ravazzi, PA
    Curnis, A
    Puglisi, A
    Klersy, C
    Vicini, I
    Cavaglià, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01): : 148 - 151
  • [8] Update of implantable cardioverter/defibrillator and cardiac resynchronization therapy in heart failure
    Rami, T
    Shih, HT
    CURRENT OPINION IN CARDIOLOGY, 2004, 19 (03) : 264 - 269
  • [9] Cardiac Resynchronization Therapy and Implantable Cardioverter Defibrillator Therapy in Advanced Heart Failure
    Choi, Anthony J.
    Thomas, Sunu S.
    Singh, Jagmeet P.
    HEART FAILURE CLINICS, 2016, 12 (03) : 423 - +
  • [10] Automatic home monitoring in patients with implantable cardioverter defibrillator or cardiac resynchronization therapy defibrillator
    Wang Fengmei
    Zhang Shuo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (16) : C157 - C157