On neglecting chemical exchange effects when correcting in vivo 31P MRS data for partial saturation

被引:19
|
作者
Ouwerkerk, R [1 ]
Bottomley, PA [1 ]
机构
[1] Johns Hopkins Univ, Dept Radiol, Sch Med, Div MR Res, Baltimore, MD 21287 USA
关键词
chemical exchange; saturation factors; longitudinal relaxation; dual angle method; progressive saturation; creatine kinase; P-31; MRS;
D O I
10.1006/jmre.2000.2166
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Signal acquisition in most MRS experiments requires a correction for partial saturation that is commonly based on a single exponential model for T-1 that ignores effects of chemical exchange. We evaluated the errors in P-31 MRS measurements introduced by this approximation in two-, three-, and four-site chemical exchange models under a range of flip-angles and pulse sequence repetition times (T-R) that provide near-optimum signal-to-noise ratio (SNR). In two-site exchange, such as the creatine-kinase reaction involving phosphocreatine (PCr) and gamma -ATP in human skeletal and cardiac muscle, errors in saturation factors were determined for the progressive saturation method and the dual-angle method of measuring T-1. The analysis shows that these errors are negligible for the progressive saturation method if the observed T-1 is derived from a three-parameter fit of the data. When T-1 is measured with the dual-angle method, errors in saturation factors are less than 5% for all conceivable values of the chemical exchange rate and flip-angles that deliver useful SNR per unit time over the range T-1/5 less than or equal to T-R less than or equal to 2T(1). Errors are also less than 5% for three- and four-site exchange when T-R greater than or equal to T-1*/2, the so-called "intrinsic" T-1's of the metabolites. The effect of changing metabolite concentrations and chemical exchange rates on observed T-1's and saturation corrections was also examined with a three-site chemical exchange model involving ATP, PCr, and inorganic phosphate in skeletal muscle undergoing up to 95% PCr depletion. Although the observed T-1's were dependent on metabolite concentrations, errors in saturation corrections for T-R = 2 s could be kept within 5% for all exchanging metabolites using a simple interpolation of two dual-angle T-1 measurements performed at the start and end of the experiment. Thus, the single-exponential model appears to be reasonably accurate for correcting P-31 MRS data for partial saturation in the presence of chemical exchange. Even in systems where metabolite concentrations change, accurate saturation corrections are possible without much loss in SNR. (C) 2001 Academic Press.
引用
收藏
页码:425 / 435
页数:11
相关论文
共 50 条
  • [31] Absolute quantification of phosphorus metabolite concentrations in human muscle in vivo by 31P MRS:: a quantitative review
    Kemp, Graham J.
    Meyerspeer, Martin
    Moser, Ewald
    NMR IN BIOMEDICINE, 2007, 20 (06) : 555 - 565
  • [32] 31P MRS Study of Hyperbaric Oxygenation Effects on Phosphate Metabolism of Normal Human Brain
    Manzhurtsev, A. V.
    Vasiukova, O. R.
    Sergeeva, V. V.
    Zaitseva, N. L.
    Menshchikov, P. E.
    Melnikov, I. A.
    Akhadov, T. A.
    Semenova, N. A.
    APPLIED MAGNETIC RESONANCE, 2018, 49 (07) : 679 - 686
  • [33] 31P MRS Study of Hyperbaric Oxygenation Effects on Phosphate Metabolism of Normal Human Brain
    A. V. Manzhurtsev
    O. R. Vasiukova
    V. V. Sergeeva
    N. L. Zaitseva
    P. E. Menshchikov
    I. A. Melnikov
    T. A. Akhadov
    N. A. Semenova
    Applied Magnetic Resonance, 2018, 49 : 679 - 686
  • [34] Intracellular Redox State Revealed by In Vivo 31P MRS Measurement of NAD+ and NADH Contents in Brains
    Lu, Ming
    Zhu, Xiao-Hong
    Zhang, Yi
    Chen, Wei
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) : 1959 - 1972
  • [35] Evidence of Altered Neuropil Development in ADHD Children: A Longitudinal In Vivo 31P MRS Study at 3 Tesla
    Stanley, Jeffrey A.
    Wu, Helen
    Goradia, Dhruman D.
    Khatib, Dalal
    Rajan, Usha
    Burgess, Ashley
    Robin, Arthor L.
    Rosenberg, David R.
    BIOLOGICAL PSYCHIATRY, 2015, 77 (09) : 108S - 108S
  • [36] Effects of combretastatin on murine tumours monitored by 31P MRS, 1H MRS and 1H MRI
    Maxwell, RJ
    Nielsen, FU
    Breidahl, T
    Stodkilde-Jorgensen, H
    Horsman, MR
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (04): : 891 - 894
  • [37] 3T 31P/1H calf muscle coil for 1H and 31P MRI/MRS integrated with NIRS data acquisition
    Zhang, Bei
    Lowrance, Daniel
    Sarma, Manoj Kumar
    Bartlett, Miles
    Zaha, David
    Nelson, Michael D.
    Henning, Anke
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (06) : 2638 - 2651
  • [38] A critical assessment of noise-induced errors in 31P MRS: Application to the measurement of free intracellular magnesium in vivo
    Physiology/Pharmacology Department, School of Molecular Sciences, James Cook University, Townsville, QLD 4811, Australia
    MAGN. RESON. MED., 2 (174-185):
  • [39] Focal and global alterations of membrane phospholipid metabolism in offspring subjects of schizophrenia parents: An in vivo 31P MRS study
    Stanley, JA
    Pettegrew, JW
    Panchalingam, K
    McClure, RJ
    Harenski, K
    Montrose, DM
    Keshaven, MS
    SCHIZOPHRENIA RESEARCH, 2001, 49 (1-2) : 195 - 196
  • [40] Effect of transient ischemia on rat brain energy metabolism assessed in vivo by 31P MRS and in vitro by mitochondrial oxphos
    Horecky, J.
    Baciak, L.
    Vancova, O.
    Wimmerova, S.
    Kasparova, S.
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 2006, : 178 - 179